Chaffoteaux & Maury wall-hung gas appliances offer great flexibility in flueing arrangements, to accommodate all installation requirements. This technical guide will help you to select the correct flue and components, for the location of the boiler within a property.
1 - Standard Horizontal
The standard flue can rotate through a full 360? allowing the greatest flexibility in siting.
2 - Raised Horizontal
Using a vertical adaptor together with standard flue extensions it is possible to extend the overall length of a standard flue and still terminate horizontally.
3 - Vertical
For situations where it is necessary to terminate the flue vertically through a tiled or flat roof.
4 - Twin Pipe (Biflux)
Suitable for applications where the appliance is either sited further from a suitable external wall or where building obstructions do not allow conventional horizontal or vertical flueing arrangements.
3 1
4 2
2 - C&M - Flueing options and accessories
Supplied By heating spares.co Tel. 0161 620 6677
GAS BOILERS
chaffoteaux.co.uk
Flue Terminal Positions
In accordance with BS 5440-1:2000
H F L
JK
DE
A B C
P E
H I
P
M N
I
Installation Conditions
Terminal Position A Directly below an opening, air brick, opening windows, etc B Above an opening, air brick, opening windows, etc C Horizontally to an opening, air brick, opening windows, etc D Below gutters, soil pipes or drain pipes E Below eaves F Below balconies or car port roof G From vertical drain or soil pipe H From an internal or external corner I Above ground roof or balcony level J From a surface facing the terminal K From a terminal facing the terminal L From an opening in the car port (e.g. door, window) into the dwelling M Vertically from a terminal on the same wall N Horizontally from a terminal in the same wall P Fixed by use of terminal and matched flashing plate
mm 300 300 300 75 200 200 150 300 300 600 1200 1200 1500 300 -
C&M - Flueing options and accessories - 3
Supplied By heating spares.co Tel. 0161 620 6677
Flue Types
Standard horizontal
C&M wall-hung appliances can be fitted up to 4 metres from an outside wall using the standard horizontal flue kit. Full 360? rotation of the flue allows the greatest flexibility. The optional 45? and 90? bends make the system ideal for boiler changes. With a special rubber sealing ring the flue can be installed and sealed externally at high levels without requiring access to the outside. Unobtrusive terminal. The standard kit contains all that is necessary for a basic installation. Full range of accessories available.
Horizontal incorporating 2 x 45? bends
Horizontal incorporating 45? or 90? bend
Raised horizontal
C&M wall-hung appliances can be fitted up to 15 metres from an outside wall using 80/125mm flue components (4 metres using 60/100mm flue components).
As long as the flue terminates horizontally, the main length of the flue can be vertical.
Uses standard straight flue extensions and bends.
With a special rubber sealing ring the flue can be installed and sealed externally at high levels without requiring access to the outside (60/100mm only).
Unobtrusive terminal.
Simply add bends and straight extensions as required to complete the installation (60/100mm only).
For 80/125mm use the 80/125 vertical adaptor.
Full range of accessories available.
Raised Horizontal, side exit
Raised Horizontal incorporating 2 x 90? bend and straight extensions
4 - C&M - Flueing options and accessories
Supplied By heating spares.co Tel. 0161 620 6677
GAS BOILERS
chaffoteaux.co.uk
Vertical
Flue can terminate vertically up to 16 metres away from the boiler using the 80/125mm Vertical Flue Kit (5 metres using the 60/100mm Vertical Flue Kit).
Removes the need to fit the boiler near an outside wall.
A multitude of accessories make a very adaptable and flexible flue system.
Vertical terminals for flat, sloping, tiled or slated roofs available.
Terminals and Flashings available in terracotta finish to special order.
Vertical Flue incorporating 2 x 90? bends
Vertical Flue incorporating 1 x 90? bend and 2 x 45? bends
Twin Pipe (Biflux)
The ultimate in flexibility.
C&M wall-hung boilers can be fitted with up to 30 metres of Biflux flue.
Can terminate on flat, sloping, slated or tiled roofs.
Vertical, horizontal and even separate terminals are available.
Full range of accessories available.
Twin Pipe Flue with single vertical terminal
C&M - Flueing options and accessories - 5
Supplied By heating spares.co Tel. 0161 620 6677
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- denox desox and co2 removal technology for
- gas boilers flue systems heating spares ltd
- venting reinvented ul 1738 fuel gas venting systems
- logic flue accessories guide
- technical guide
- air pollution control technology fact sheet
- section 23 51 00 breechings chimneys and stacks
- mobile home heating systems
- section 23 52 39 fire tube boilers veterans affairs
- safety data sheet fluesystems
Related searches
- new benefits ltd dallas tx
- this years flue strain 2019
- 2020 offensive security ltd all rights reserved
- flue systems
- heating and cooling systems prices
- home heating systems comparison
- home heating systems cost comparisons
- best heating systems for homes
- ductless heating and cooling systems prices
- 12 flue pipe
- 12 double wall flue pipe
- new heating systems for homes