GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED ...

TM 5-6115-323-14 DEPARTMENT OF THE ARMY TECHNICAL MANUAL

TO 35C2-3-385-1 DEPARTMENT OF THE AIR FORCE TECHNICAL ORDER

TECHNICAL MANUAL

OPERATOR/CREW, ORGANIZATIONAL, INTERMEDIATE (FIELD) (DIRECT SUPPORT AND GENERAL SUPPORT) AND DEPOT MAINTENANCE MANUAL

GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 1.5 KW, SINGLE PHASE, AC, 120/240 V, 28 V DC (LESS ENGINE)

DOD MODELS

MEP-015A MEP-025A

HERTZ

60 DC

NSN

6115-00-889-1446 6115-00-017-8236

HEADQUARTERS, D E P A R T M E N T O F T H E A R M Y and AIR FORCE 1976

WARNING

Take particular heed to specific cautions and warnings throughout this manual.

TM 5-6115-323-14 TO 35C2?3-385-1

HIGH VOLTAGE

is used in the operation of this equipment.

DEATH

or severe burns may result if personnel fail to observe safety precautions. Do not operate this generator set until the ground terminal stud has been connected to a suitable ground. On gasoline engine driven generator sets utilizing magnetos, set magneto switch to OFF or STOP position. Do not attempt to change load connections when generator is running.

Before servicing any part of a generator set, make sure unit is completely de-energized.

DANGEROUS GASES

are generated as a result of operating this equipment.

DEATH

or severe injury may result if personnel fail to observe safety precautions. Do not smoke, or use open flame when servicing batteries. Batteries generate explosive gas while discharging and charging. Always maintain metal-to-metal contact when filling the fuel tank. Do not smoke or use open flame when filling the fuel tank. Do not attempt to fill the fuel tank when the generator is running. Do not operate generator sets in inclosed areas unless exhaust gases are properly vented to the outside. Exhaust discharge contains noxious and deadly fumes.

NOISE

Operation of this equipment presents a noise hazard to personnel in the area. The noise level exceeds the allowable limits for unprotected personnel. Wear ear muffs or ear plugs which were fitted by a trained professional.

CAUTION

DAMAGE

to the equipment may result if personnel fail to observe safety precautions.

If the generator set is shut-down by the operation of a safety device, do not attempt to operate the unit until the cause has been determined and eliminated.

WARNING

Dry cleaning solvent, P?D?680, used to clean parts is potentially dangerous to personnel and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100?F.-138?F. (38?C.-59?C.).

CHANGE NO. 10

ARMY TM 5-6115-323-14 AIR FORCE TO 35C2-3-385-1

C 10

HEADQUARTERS DEPARTMENTS OF THE ARMY AND AIR FORCE

WASHINGTON, D.C., 25 September 1996

Operator/Crew, Organizational, Intermediate (Field) (Direct Support and General Support) and Depot Maintenance Manual

GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 1.5 KW, SINGLE PHASE, AC, 120/240 V, 28 V DC (LESS ENGINE)

DOD MODEL

HERTZ

NSN

MEP-015A MEP-025A

60 28 V DC

6115-00-889-1446 6115-00-017-8236

DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited

TM 5-6115-323-14/TO 35C2-3-385-1, 23 July 1976, is changed as follows:

1.

Remove and insert pages as indicated below. New or changed text material is indicated by a vertical bar in the

margin. An illustration change is indicated by a miniature pointing hand.

Remove pages

Insert pages

i and ii 1-1 and 1-2 B-1 and B-2

i and ii 1-1 and 1-2 B-1 and B-2

2.

Retain this sheet in front of manual for reference purposes.

CHANGE NO. 9

TM 5-6115-323-14 TO 35C2-3-385-1

C9 HEADQUARTERS

DEPARTMENTS OF THE ARMY AND AIR FORCE

WASHINGTON, D.C., 17 September 1991

Opcrator/Crew, Organizational, Intermediate (Field) (Direct Support and General Support) and Depot Maintenance Manual

GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 1.5 KW, SINGLE PHASE, AC, 120/240 V, 28 V DC (LESS ENGINE)

DOD MODEL

HERTZ

NSN

MEP-015A MEP-025A

60 28 V DC

6115-00-889-1446 6115-00-017-8236

Approved for public release; distribution is unlimited

TM 5?6115?323?14, 23 July 1976, is changed as follows:

1. Remove and insert pages as indicated below. New or changed text material is indicated by a vertical bar in the margin. An illustration change is indicated by a miniature pointing hand.

Remove pages

Insert pages

4?13through 4-16 6-1 and 6-2 8?5 and 8-6

4?13 through 4?16 6-1 and 6-2 8?5 and 8?6

2. Retain this sheet in front of manual for reference purposes.

TM 5-6115-323-14 TO 35C2-3-385-1

C9 By Order of the Secretaries of the Army and Air Force:

GORDON R. SULLIVAN General, United States Army

Chief of Staff

Official: PATRICIA P. HICKERSON

Brigadier General, United States Army The Adjutant General

MERRILL A. McPEAK General USAF Chief of Staff

Official: CHARLES C. McDONALD General, USAF

Commander, Air Force logistics Command

DISTRIBUTION: To be distributed in accordance with DA Form 12-25E, (qty rqr block no. 0874)

CHANGE NO. 8

TM 5-6115-323-14 TO 35C2-3-385-1 C8

HEADQUARTERS, DEPARTMENTS OF THE ARMY AND AIR FORCE

WASHINGTON, D.C., 24 OCTOBER 1990

Operator/Crew, Organizational, Intermediate (Field) (Direct Support and General Support) and Depot Maintenance Manual

GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME,

1.5 kW, SINGLE PHASE, AC, 120/240 V, 28 V DC (LESS ENGINE)

DOD MODEL

HERTZ

NSN

MEP-015A MEP-025A

60 28V DC

6115-00-889-1446 6115-00-017-8236

Approved for public release; distribution is unlimited

TM 5-6115?323-14, 23 July 1976 is changed as follows:

1. Remove and insert pages as indicated below. New or changed text material is indicated by a vertical bar in the margin. An illustration change is indicated by a miniature pointing hand.

Remove pages

Insert pages

3-2.1 and 3-2.2 4-11 through 4-16 5-3 and 5-4 6-1 and 6-2 8-1 and 8-2 8-5 and 8-6 B?1 and B-2 C-5/(C-6 blank)

3-2.1 and 3-2.2 4-11 through 4-16 5-3 and 5-4 6-1 and 6-2 8-1 and 8-2 8?5 and 8-6 B?1 and B?2 C-5 and C-6

2. Retain this sheet in front of manual for reference purposes.

TM 5-6115-323-14 TO 35C2--3-385-l

C8 By Order of the Secretary of the Army:

CARL E. VUONO General, United States Army

Chief of Staff

Official: THOMAS F. SIKORA

Brigadier General, United States Army The Adjutant General

MERRILL A. McPEAK General USAF Chief of Staff

Official: CHARLES C. MCDONALD General, USAF

Commander, Air Force Logistics Command

DISTRIBUTION: To be distributed in accordance with DA Form 12?25E, (qty rqr block no. 0874).

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download