Hhs.texas.gov



This draft shows changes in Texas Administrative Code (TAC) references that were effective January 15, 2021. Rules in 40 TAC Social Services Assistance, Part 1, Department of Aging and Disability Services, Chapter 19, Nursing Facility Requirements for Licensure and Medicaid Certification were transferred to 26 TAC Health and Human Services, Part 1, Texas Health and Human Services Commission, Chapter 554, Nursing Facility Requirements for Licensure and Medicaid Certification.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSIONCHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 1GENERAL PROVISIONS§554.300. General Requirements.(a) The facility must be designed, constructed, equipped, and maintained to protect the health and ensure the safety of residents, personnel, and the public.(b) If children are admitted to the facility, accommodations, furnishings, and equipment appropriate to children must be provided, including the following;(1) The facility must provide indoor and outdoor recreation areas designed to encourage exploration within the children's capabilities.(2) The facility must provide pediatric equipment and supplies in appropriate sizes for the age and development level of the children. Pediatric emergency supplies and equipment must be readily available for use.(3) The environment must be the least restrictive allowable while remaining within the parameters of safety. All areas of the facility accessible to children must be "child proof" for safety hazards. This type of safety proofing is above the normal level of hazard control maintained for adult residents and includes the addition of safety covers on electrical outlets not in use that are accessible to children.(4) Pediatric resident's rooms must be decorated and furnished in accordance with the age and developmental level of the children and as an expression of their individual preferences.(c) HHSC may grant a waiver for certain provisions regarding the physical plant and environment that, in the opinion of HHSC, would be impractical for the facility to meet. In granting the waiver, HHSC must determine that granting the waiver has no adverse effect on resident health and safety and the requirement, if not waived, would impose an unreasonable hardship on the facility. HHSC may require offsetting or equivalent provisions in granting a waiver.(d) The requirements of this subchapter are applicable to nursing facilities as follows:(1) All nursing facilities must comply with division 3 of this subchapter (relating to Provisions Applicable to All Facilities). (2) A nursing facility or a portion of a nursing facility licensed before September 11, 2003, and continually operated as a licensed nursing facility, must comply with division 2 of this subchapter (relating to Facilities Licensed Before September 11, 2003). (3) A nursing facility or a portion of a nursing facility licensed or constructed, on or after September 11, 2003, but before April 2, 2018, and continuously operated as a licensed nursing facility, must comply with division 5 of this subchapter (relating to Facilities Licensed on On or After September 11, 2003 and Before April 2, 2018).(4) A nursing facility or a portion of a nursing facility licensed or constructed on or after April 2, 2018, must comply with division 9 of this subchapter (relating to Facilities Licensed on On or After April 2, 2018).(5) A small house or household facility is a facility that is designed to provide a non-institutional environment to promote resident-centered care and that meets the requirements of §554.345§19.345 of this subchapter (relating to Small House and Household Facilities). New construction of a small house or household facility must meet the requirements of §554.345§19.345 of this subchapter.(e) A facility must comply with NFPA 101; NFPA 99, except Chapters 7, 8, 12, and 13; and a Tentative Interim Amendment (TIA) issued by NFPA, including the TIAs listed in paragraphs (1) and (2) of this subsection. A facility must also comply with other NFPA publications referenced in NFPA 101 or in this chapter, unless otherwise approved by HHSC.(1) The following TIAs have been issued for NFPA 101:(A) TIA 12-1, issued August 11, 2011;(B) TIA 12-2, issued October 30, 2012;(C) TIA 12-3, issued October 22, 2013; and(D) TIA 12-4, issued October 22, 2013.(2) The following TIAs have been issued for NFPA 99:(A) TIA 12-2, issued August 11, 2011;(B) TIA 12-3, issued August 9, 2012;(C) TIA 12-4, issued March 7, 2013;(D) TIA 12-5, issued August 1, 2013; and(E) TIA 12-6, issued March 3, 2014;(F) TIA 12-7, issued December 1, 2016; and(G) TIA 12-8, issued April 10, 2018.(f) Building rehabilitation on existing buildings shall be classified in accordance with NFPA 101 and shall comply with NFPA 101 and §554.350§19.350 of this subchapter (relating to Building Rehabilitation).(g) Buildings, or portions of buildings, may be occupied during construction, repair, alterations, or additions only when required means of egress and required fire protection features are in place and continuously maintained for the portion occupied, or when alternative life safety measures acceptable to HHSC are in place.(h) No existing life safety feature shall be removed or reduced when the feature is a requirement for new construction. Life safety features and equipment that have been installed in existing buildings, if not required by NFPA 101, must continue to be maintained or may be completely removed if prior approval is obtained from HHSC.(i) The facility must perform a risk assessment in accordance with NFPA 99.(1) The risk assessment must follow and document the defined risk assessment procedure used.(2) The results of the assessment procedure must be documented and records retained.(3) A building system required by NFPA 99 shall be designed to meet the risk categories determined for each system as part of this assessment. At a minimum, any new systems or equipment must be designed to meet the requirements for Category 2 risk, as defined in NFPA 99.(4) The assessment must be reviewed and a new assessment performed, if necessary, on an annual basis and when the facility identifies changes in resident care needs that cannot be met by the currently installed systems and equipment.(5) In addition to the requirements of NFPA 99 based on the risk assessment, a facility must also meet all applicable requirements of this subchapter.(j) A wing or area that is separated from the rest of the facility by locked doors, or a facility that is locked in its entirety, for the purpose of securing residents must meet the requirements of §554.2208(a)(6) and (c)(1) - (10)§19.2208(a)(6) and (c)(1) - (10) of this chapter (relating to Standards for Certified Alzheimer's Facilities).§554.301. Definitions.The following words and terms, when used in this subchapter, have the following meanings, unless the context clearly indicates otherwise. The definitions listed in §554.101§19.101 of this chapter (relating to Definitions) also apply to this subchapter.(1) Alarm Planning Superintendent--Fire Alarm Planning Superintendent. A person licensed by the State Fire Marshal’s Office to plan, install, certify, inspect, test, service, monitor, and maintain fire alarm or fire detection devices. (2) ANSI--American National Standards Institute.(3) ASHRAE--Formerly American Society of Heating, Refrigerating and Air-Conditioning Engineers. A global society focusing on building systems, energy efficiency, indoor air quality, refrigeration, and sustainability.(4) ASME--The American Society of Mechanical Engineers, a developer of codes and standards associated with the art, science, and practice of mechanical engineering.(5) ASME A17.1--Safety Code for Elevators and Escalators, 2007 edition, published by ASME.(6) ASME A17.3--Safety Code for Existing Elevators and Escalators, 2008 edition, published by ASME.(7) (6) ASTM--ASTM International, a not-for-profit, voluntary standards developing organization that develops and publishes international voluntary consensus standards for materials, products, systems, and services.(8) (7) ASTM E84--Standard Test Method for Surface Burning Characteristics of Building Materials, 2010, published by ASTM.(9) (8) ASTM E90--Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, published by ASTM.(10) (9) ASTM E108--Standard Test Methods for Fire Tests of Roof Coverings, published by ASTM.(11) (10) ASTM E662--Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials, 2017, published by ASTM.(12) (11) Building Rehabilitation--Any construction activity involving repair, modernization, reconfiguration, renovation, changes in occupancy or use, or installation of new fixed equipment, including, the following:(A) the replacement of finishes, such as new flooring or wall finishes or the painting of walls and ceilings;(B) the construction, removal, or relocation of walls, partitions, floors, ceilings, doors, or windows;(C) the replacement of doors, windows, or roofing;(D) changes to the appearance of the exterior of a building, including new finish materials;(E) the repair, replacement, or extension of fire protection systems, including fire sprinkler systems, fire alarm system, and fire suppression systems at cooking operations;(F) the replacement of door hardware, plumbing fixtures, handrails in corridors, or grab rails in bathrooms and restrooms;(G) the repair, replacement, or extension of nurse call systems;(H) the repair or replacement of emergency electrical system equipment and components, including generator sets, transfer switches, distribution panel boards, receptacles, switches, and light fixtures;(I) the change of a wing or area to a secured wing or unit;(J) the change of a secured wing or unit to ordinary resident-use;(K) a change in the use of space, including the change of resident bedrooms to other uses, such as offices, storage, or living or dining spaces; and,(L) changes in locking arrangements, such as the installation of access control systems or the installation or removal of electronic locking devices, including electromagnetic locks, and other delayed-egress locking devices.(13) NFPA 10--Standard for Portable Fire Extinguishers, 2010 edition.(14) (12) NFPA 13--Standard for the Installation of Sprinkler Systems, 2010 edition.(15) (13) NFPA 25--Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2011 edition.(16) (14) NFPA 37--Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines, 2010 edition.(17) (15) NFPA 54--National Fuel Gas Code, 2012 edition.(18) (16) NFPA 55--Compressed Gases and Cryogenic Fluids Code, 2010 edition.(19) (17) NFPA 58--Liquefied Petroleum Gas Code, 2011 edition.(20) (18) NFPA 70--National Electrical Code, 2011 edition.(21) (19) NFPA 72--National Fire Alarm and Signaling Code, 2010 edition.(22) (20) NFPA 90A--Standard for the Installation of Air-Conditioning and Ventilating Systems, 2012 edition.(23) (21) NFPA 96--Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, 2011 edition.(24) (22) NFPA 110--Standard for Emergency and Standby Power Systems, 2010 edition.(25) (23) NFPA 220--Standard on Types of Building Construction, 2012 edition.(26) (24) NFPA 255--Standard Method of Test of Surface Burning Characteristics of Building Materials. This document was withdrawn by NFPA in 2009 in lieu of ASTM E84 and UL 723.(27) (25) NFPA 258--Recommended Practice for Determining Smoke Generation of Solid Materials. This document was withdrawn by NFPA in 2006 in lieu of ASTM E662.(28) (26) Patient care vicinity--A space extending 6 ft. (1.8 m) horizontally in all directions around the resident bed and extending vertically to 7 ft. 6 in. (2.3 m) above the floor. If the dimension between the bed and a wall or partition is less than 6 ft. (1.8 m), the limit of the patient care vicinity is at the wall or partition.(29) (27) RME--Responsible Managing Employee. A person licensed by the State Fire Marshal’s Office who is designated by a registered fire sprinkler firm to ensure that any fire protection sprinkler system, as planned, installed, maintained, or serviced, meets the standards provided by law. The type of RME license issued determines the type of fire sprinkler services the fire sprinkler firm may perform.(30) (28) TAS--Texas Accessibility Standards.(29) Texas Natural Resource Conservation Commission--The predecessor agency to TCEQ(31) (30) TCEQ--Texas Commission on Environmental Quality.(32) (31) UL--UL LLC, formerly Underwriters’ Laboratory.(33) (32) UL 723--Standard for Test for Surface Burnings Characteristics of Building Materials.(34) (33) UL 790--Standard Test Methods for Fire Tests of Roof Coverings.(35) (34) UL 1069--Standard for Hospital Signaling and Nurse Call Equipment.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 2FACILITIES LICENSED BEFORE SEPTEMBER 11, 2003§554.310. Site and Grounds.(a) Site grades must provide for positive surface water drainage so that there will be no ponding or standing water at or near the building that would present a hazard to health or provide a breeding site or harborage for carriers of disease.(b) Outdoor activity, recreational, and sitting spaces must be provided for residents as space permits.(c) Each facility must have parking spaces to satisfy the needs of residents, employees, staff, and visitors. Provisions must be made for handicapped parking and access into the building.(d) Protection must be provided for resident safety from traffic or other site hazards by the use of appropriate methods, such as fences, hedges, retaining walls, railings, or other landscaping. This protection must not inhibit the free emergency egress to a safe distance away from the building.(e) Auxiliary buildings located on the site within 20 feet of the main licensed structure and which contain hazardous operations or contents, such as laundries or storage buildings, must meet the same code requirements for safety as the main licensed structure.(f) Other buildings on the site must meet the appropriate occupancy section or separation requirements of NFPA 101the Life Safety Code.(g) All outside areas, grounds, and adjacent buildings on the site must be maintained in good condition and kept free of rubbish, garbage, and untended growth that may constitute a fire or health hazard.(h) Enclosed exterior spaces, such as fenced areas, that are in a means of egress to a public way must meet the requirements of §554.2208(a)(6)§19.2208(a)(6) of this chaptertitle (relating to Standards for Certified Alzheimer's Facilities).§554.311. Fire ServicesService and Access.(a) The facility must be served by a paid or volunteer fire department. The fire department must provide written assurance to the licensing agency that the fire department can respond to an emergency at the facility within an appropriately prompt time for the travel conditions.(1) The fire department must provide written assurance to the licensing agency that the fire department can respond to an emergency at the facility within an appropriately prompt time for the travel conditions involved.(2) The facility must have an annual inspection by the local fire marshal and maintain documentation of such an inspection at the facility.(b) The facility must be served by an adequate water supply that is satisfactory and accessible for fire department use as determined by the fire department serving the facility and by HHSCthe Texas Department of Human Services (DHS).(c) There must be at least one approved, readily accessible fire hydrant located within 300 feet of the building. The hydrant must be on a minimum six-inch service line, or else there must be an approved equivalent, such as a storage tank. The hydrant, its location, and service line, or equivalent must be approved by the local fire department and HHSCDHS.(d) The building must have suitable fire lanes for access as required by local fire authorities and HHSCDHS.§554.313. Interior Finishes--Walls, Ceilings, and Floors.(a) Interior finishes of walls and ceilings must have limited flame-spread rating as required by the Life Safety Code. Where new interior finishes of walls, ceilings, or floors are applied to existing facilities, the new finishes must meet the requirements for flame-spread ratings for new construction. Fire retardant paints or solutions must not be applied to new materials in an effort to meet flame-spread requirements for new construction. This description of interior finishes does not apply to furniture or accessories.(b) Floors of the facility must be level, smooth, and free of any irregularities which might affect safety.(c) Walls and ceilings not specifically described elsewhere in this chapter must be cleanable, maintained attractively, and in good repair.(d) Walls and floors must be kept free of cracks. The joint between the walls and floors is to be maintained so as to be free of spaces which might harbor insects, rodents, or vermin.§554.314. Fire Alarms, Detection Systems, and Sprinkler Systems.Fire alarms, detection systems, and sprinkler systems must be as required by NFPA 101, NFPA 72the Life Safety Code, the National Fire Protection Association (NFPA) 72, and NFPA 13.(1) Components must be compatible and laboratory listed for the use intended.(2) Wiring and circuitry for alarm systems must meet the applicable requirements for NFPA standards, including NFPA 70, for these systems.(3) Fire alarm systems must be installed, maintained, and repaired by an agent having a current certificate of registration with the State Fire Marshal's Office of the Texas Commission on Fire Protection, in accordance with state law. A fire alarm installation certificate must be provided as required by the Office of the State Fire Marshal.(4) Smoke detector sensitivity must be checked within one year after installation and every alternate year thereafter in accordance with NFPA 72. Documentation, including as-built installation drawings, operation and maintenance manuals, and a written sequence of operation for systems installed after July 1, 2000, must be available for examination by HHSCthe Texas Department of Human Services (DHS).(5) The fire alarm system must be designed so that whenever the general alarm is sounded by activation of any device (such as manual pull, smoke sensor, sprinkler, or kitchen range hood extinguisher) the following will occur automatically:(A) smoke and fire doors which are held open by an approved device must be released to close;(B) air handlers (air conditioning/heating distribution fans) serving three or more rooms or any means of egress must shut down immediately;(C) smoke dampers must close; and(D) the alarm-initiating location must be clearly indicated on the fire alarm control panel(s) and all auxiliary panels.(6) Consistent fire alarm bells or horns must be located throughout the building for audible coverage. Flashing alarm lights (visual alarms) must be installed to be visible in corridors and public areas including dining rooms and living rooms.(7) A master control panel which indicates location of alarm and trouble conditions (by zone or device) must be visible at the main nurse station. All control panels must be listed in accordance with the provisions of the Underwriters Laboratories, Inc. (UL) for intended use, such as manual, automatic, and water-flow activation. Alarm and trouble zoning must be by smoke compartments and by floors in multi-story facilities.(8) Remote annunciator panels, indicating location of alarm initiation by zone or device and common trouble signals, must be located at auxiliary or secondary nurses stations on each floor or major subdivision of single story facilities and indicate the alarm condition of adjacent zones and the alarm conditions at all other nurse stations.(9) Manual pull stations must be provided at all exits, living rooms, dining rooms, and at or near the nurse stations.(10) The NFPA 13 sprinkler system must be monitored for flow and tamper conditions by the fire alarm system.(11) The kitchen range hood extinguisher must be interconnected with the fire alarm system. This interconnection may be a separate zone on the panel or combined with other initiating devices located in the same zone as the range hood is located.(12) Partial sprinkler systems provided only for hazardous areas must be interconnected to the fire alarm system and comply with NFPA 101the Life Safety Code. Each partial system must have a valve with a supervisory switch to sound a supervisory signal, water-flow switch to activate the fire alarm, and an end-of-line test drain.§554.315. Portable Fire Extinguishers.Portable fire extinguishers must be provided and maintained to comply with the provisions of NFPA 10the National Fire Protection Association (NFPA) 10. This includes type of extinguishers (A, B, or C), location and spacing, mounting heights, monthly inspections by staff, yearly inspections by a licensed agent, any necessary servicing, and hydrostatic testing as recommended by the manufacturer.(1) Extinguishers in resident corridors must be spaced so that travel distance is not more than 75 feet. The minimum size of extinguishers must be either 2 1/2 gallon for water type or five pound for ABC type.(2) Extinguishers must be installed on supplied hangers or brackets or be mounted in cabinets approved HHSCby the Texas Department of Human Services (DHS).(3) Extinguishers must be surface wall-mounted or recessed in cabinets where they are not subject to physical damage or dislodgement.(4) Extinguishers having a gross weight not exceeding 40 pounds must be installed so that the top of the extinguisher is not more than five feet above the floor. Extinguishers with a gross weight greater than 40 pounds must be installed so the top of the extinguisher is not more than 3-1/2 feet above the floor. The clearance between the bottom of the extinguisher and the floor must not be less than four inches.(5) Portable extinguishers provided in hazardous rooms must be located as close as possible to the exit door opening and on the latch (knob) side.(6) Staff must be appropriately trained in the use of each type of extinguisher in the facility.§554.316. Subdivision of Building Spaces--Smoke Barriers.(a) Subdivision of building spaces must be as required by NFPA 101the Life Safety Code.(b) The facility must maintain the integrity of smoke barrier walls, including those parts of walls in attics and other concealed spaces.(c) The facility must maintain the integrity of smoke dampers in air ducts.(d) Ducts with smoke dampers must have maintenance panels for inspection. The maintenance panels must be removable without tools. Means of access must also be provided in the ceiling or side wall to facilitate smoke damper inspection readily and without obstruction. Location of dampers must be identified on the wall or ceiling of the occupied area below.§554.317. Elevators and Escalators.Elevators must comply with the provisions of NFPA 101 and ASME A17.3the Life Safety Code and American National Standard Institute Safety Code for Elevators and Escalators (ANSI/ASME A17.1). Elevators are required for buildings having residents' facilities, such as bedrooms, dining, or recreation areas; or services, such as diagnostic or therapy, located on other than the main entrance floor. Passenger elevators and escalators must be inspected by a qualified agent at least every six months. Freight elevators must be inspected every 12 months.§554.321. Heating, Ventilating, and Air-conditioning Systems (HVAC).(a) The heating system must be capable of maintaining a temperature of not less than 71 degrees Fahrenheit at the resident level in all resident-use areas. Auxiliary heating devices permanently installed, such as heat strips in ducts, electric ceiling-mounted heating units, and electric baseboards, may be used to augment a central heating system as approved by HHSC, as described in §554.705 of this chapter (relating to Environment).(1) Auxiliary heating devices permanently installed, such as heat strips in ducts, electric ceiling-mounted heating units, and electric baseboards, may be used to augment a central heating system as approved by the Texas Department of Human Services (DHS). See §19.705 of this title (relating to Environment).(2) All gas heating systems must be checked annually for proper operation and safety by persons who are licensed or approved by the State of Texas to inspect such equipment. A record of this service must be maintained by the facility. Any unsatisfactory condition must be corrected promptly.(b) The cooling system must be capable of maintaining a temperature suitable for the comfort of the residents in resident-use areas.(c) Air flow must be directed or adjusted so that a resident is not in direct drafts that could be harmful to the health and comfort of the resident.(d) Unvented heating units and portable heaters are prohibited.(e) The facility must be well ventilated through the use of windows, mechanical ventilation, or a combination of both. Rooms and areas which do not have outside windows and which are used by residents or personnel must be provided with functioning mechanical ventilation to change the air on a basis commensurate with the room usage. Air systems must provide for the induction and mixing of at least 10 percent 10% outside fresh air into the facility unless otherwise approved by HHSCDHS; that is, 100 percent 100% continuous recirculation of interior air in most areas is not acceptable. When certain rooms or areas are dependent on a central air system for proper ventilation, including exhaust, that central air system fan must run continuously.(f) Operable outside windows must be provided with insect screens. Outside doors must be self-closing to control entry of insects. All exterior doors must be effectively weather stripped.(g) Heating and air conditioning systems must be provided with clean and effective air filters.(h) Ducts and piping subject to surface condensation must be insulated to prevent condensation at least in areas which may affect sanitation or cause building deterioration.(i) A comfortable temperature for residents when bathing must be provided.(j) Heating, ventilating, and air conditioning systems must comply with the provisions of applicable National Fire Prevention Association (NFPA) standards. Ducts are to be of a Class A material (noncombustible). Combustion air for gas-fired equipment must be ducted from the exterior.(k) Air flow must be designed to prevent cross contamination within any area where applicable, such as laundries and kitchens, as well as the system or facility as a whole.(l) In relation to adjacent areas, a positive air pressure must be provided for clean utility rooms, clean linen rooms, and medication rooms. Conditioned supply air must be introduced into these rooms.(m) In relation to adjacent areas, a negative air pressure must be provided for soiled utility rooms, soiled laundry rooms, bathrooms, toilets, and other odor-producing rooms. Air from these rooms must not be recirculated, but instead must be exhausted through ducts to the exterior by effective means.(n) Facility temperature must be maintained for the comfort of residents.§554.322. Plumbing.(a) If the municipality has a plumbing code, that code must be used as a basis for determining the correctness of plumbing installation. In the absence of a municipal code, a nationally recognized plumbing code must be used.(b) The water supply must be of safe, sanitary quality, suitable for use, and adequate in quantity and pressure. The water must be obtained from a water supply system, the location, construction, and operation of which are approved by TCEQ the Texas Natural Resource Conservation Commission.(c) Sewage must be discharged into a state-approved sewerage system or the sewage must be collected, treated, and disposed of in accordance with applicable TCEQ Texas Natural Resource Conservation Commission rules and regulations.(d) The wastewater drainage and sewage system must assure that sanitation is maintained for residents. Wastewater or sewage must not be discharged on the surface of the ground. Traps must not be allowed to lose their seal. Appliances must have air gaps as required for connections to the sewerage system. Venting must assure a rapid flow of wastewater in the sewage system.(e) The interior cold water supply system and piping must be so placed or so insulated as to prevent condensation drip in habitable areas and in storage areas.(f) Backflow preventers or vacuum breakers must be installed with any water supply fixture where the outlet or attachments may be submerged.(g) Resident-use hot water must be reliably controlled, such as by thermostatic or mixing valves, to not exceed 110 degrees Fahrenheit and not less than 100 degrees Fahrenheit at each fixture.(h) Hot water for other usages must be provided at the temperatures required for the appliance or fixture or for the operation involved, such as dishwashing and laundry.(i) The supply quantity of hot water must be adequate for normal peak load usage. Facilities which continue to experience a shortage of hot water must remedy the situation by such means as adding storage tanks, adding or increasing the size of water heaters, or other approved means.(j) Water heaters must be equipped with pressure temperature relief valves.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 3PROVISIONS APPLICABLE TO ALL FACILITIES§554.326. Safety Operations.(a) The facility must have a program to inspect, test, and maintain the fire alarm system and must execute the program at least once every three months.(1) The facility must contract with a company that is registered by the State Fire Marshal's Office to execute the program.(2) A person who performs a service under the contract must be licensed by the State Fire Marshal's Office to perform the service and must complete, sign and date an inspection form similar to the inspection and testing form in NFPA 72 for a service provided under the contract.(3) The facility must ensure fire alarm system components that require visual inspection are visually inspected in accordance with NFPA 72.(4) The facility must ensure fire alarm system components that require testing are tested in accordance with NFPA 72.(5) The facility must ensure fire alarm system components that require maintenance are maintained in accordance with NFPA 72.(6) The facility must ensure smoke dampers are inspected and tested in accordance with NFPA 101.(7) The facility must maintain onsite documentation of compliance with this subsection.(b) A facility must have a program to inspect, test and maintain the sprinkler system and must execute the program at least once every three months.(1) The facility must contract with a company that is registered by the State Fire Marshal's Office to execute the program.(2) The person who performs a service under the contract must be licensed by the State Fire Marshal's Office to perform the service and must complete, sign and date an inspection form similar to the inspection and testing form in NFPA 25 for a service provided under the contract.(3) The facility must ensure sprinkler system components that require visual inspection are visually inspected in accordance with NFPA 13 and 25.(4) The facility must ensure sprinkler system components that require testing are tested in accordance with the NFPA 13 and 25.(5) The facility must ensure sprinkler system components that require maintenance are maintained in accordance with NFPA 13 and 25.(6) The facility must ensure that individual sprinkler heads are inspected and maintained in accordance with NFPA 13 and 25.(7) The facility must maintain onsite documentation of compliance with this subsection.(c) If facility staff verify or suspect a malfunction of the fire alarm, emergency electrical, or sprinkler system, the facility must immediately investigate and correct the condition. In addition, the facility must immediately report the failure of the fire alarm, emergency electrical, or sprinkler system to all facility staff and the local fire authority.(d) If emergency generators are required or provided, a facility must have a program to maintain, operate, and test all emergency generators, including all appurtenant components, and must execute the program at least once every week.(1) The facility must use a properly instructed person to oversee and execute the program.(2) The facility must ensure generator components are inspected, tested, and maintained in accordance with NFPA 37, 70, 99, and 110.(3) The facility must ensure all generators are operated, under load, for at least 30 minutes each week.(4) The person who executes the program must maintain a signed and dated record or log of inspections, tests and maintenance performed.(5) For each required operation of the generator under the program, the record or log must include the information necessary to verify:(A) the total time taken to transfer the load to emergency power;(B) the total time the generator operated under load;(C) the total time the facility's emergency system remained on generator power after restoration of normal utility power; and(D) the total time the generator operated without load after the facility's return to normal utility power.(6) The facility must ensure the condition and proper operation of all emergency lighting is inspected and tested at least once every week.(7) The facility must maintain onsite documentation of compliance with this subsection.(e) Duplex receptacles powered through the emergency electrical system must be installed at each resident bed location where resident-care-related electrical appliances are in use, unless a facility can demonstrate that it can provide the diagnostic, therapeutic, or monitoring benefits of the resident-care-related electrical appliances through acceptable alternative means in the event of a power outage.(f) A facility must conduct a functional test on every required battery emergency lighting system at 30-day intervals for a minimum of 30 seconds. The facility must also conduct an annual test for a minimum of 1 1/2 hours. The lighting system must be fully operational for the duration of the testing. The facility must maintain an onsite written record of all tests performed and make those records available to the authority having jurisdiction during an inspection.(g) A facility must ensure that a person licensed by the State Fire Marshal's Office inspects and services automatic fixed fire extinguishment systems mounted in kitchen range hoods at least once every six months in accordance with NFPA 96. The facility must maintain, onsite, a written and signed report of the inspection and service performed. The facility must keep the hood, exhaust ducts, and filters clean and free of accumulated grease.(h) A facility must inspect and maintain portable fire extinguishers.(1) Facility staff must visually inspect portable fire extinguishers monthly. Facility staff conducting the monthly visual inspection must ensure portable extinguishers are protected from damage, kept on their mounting brackets or in cabinets at all times, and kept in the proper condition and working order.(2) A facility must ensure that a person licensed by the State Fire Marshal's Office inspects and maintains portable fire extinguishers at least once every 12 months in accordance with NFPA 10.(3) The facility must maintain, onsite, a record of all fire extinguisher inspections and maintenance performed.(i) A facility using gas must have the gas piping lines between the meter and appliances tested for leaks annually by a person licensed by the State Board of Plumbing Examiners. The facility must maintain, onsite, a written and signed report of these tests. The facility must note and correct any unsatisfactory conditions immediately.(j) A facility must formulate, adopt, and enforce policies regarding smoking, smoking areas, and smoking safety that also take into account non-smoking residents.(1) The facility's policies must comply with all applicable federal, state, and local laws and regulations.(2) The facility is responsible for informing residents, staff, visitors, and other affected parties of smoking policies through the distribution and posting of policies.(3) A facility must prohibit smoking in any room, ward, or compartment where flammable liquids, combustible gas, or oxygen are used or stored and in any other hazardous locations. These areas must be posted with "No Smoking" signs.(4) A facility must provide ashtrays of noncombustible material and safe design in all areas where smoking is permitted.(5) A facility must provide a metal container with a self-closing cover device into which ashtrays can be emptied in all areas where smoking is permitted.(k) A facility must not allow storage of combustible products in facility rooms with gas-fired equipment.(l) A facility must not allow storage of volatile or flammable liquids or materials anywhere within the facility building.(m) A facility may install alcohol-based hand rub dispensers if the dispensers are:(1) installed in a manner that:(A) does not conflict with any state or local codes that prohibit or otherwise restrict the placement of alcohol-based hand rub dispensers in health care facilities;(B) minimizes leaks and spills that could lead to falls;(C) adequately protects against access by vulnerable populations; and(D) complies with NFPA 101; and(2) maintained in accordance with dispenser manufacturer guidelines.(n) A facility must not store or leave unattended medical equipment, carts, wheelchairs, tables, furniture, dispensing machines, or similar physical objects in corridors or other ways of egress, except as permitted by NFPA 101.(o) A facility must keep smoke doors, fire doors, and doors to hazardous rooms in the facility closed and not prop or wedge a door open. The facility may use only approved devices to hold open a door, such as alarm-activated electromagnetic hold-open devices, as permitted by NFPA 101.(p) The facility must post building evacuation routes at prominent locations throughout the facility.(q) A facility must provide approved electrical receptacles in quantity and location for the normal use of appliances in the facility.(r) A facility must not use electrical extension cords or multi-receptacle plug-in adaptors as a substitute for approved wiring methods in the facility.(s) A facility may use a listed and approved surge-protection device for equipment for which the manufacturer recommends surge protection, but in no case may the facility use a surge-protection device to increase the number of existing electrical outlets in a room.(t) A facility must remove all abandoned utilities, such as electrical wiring, ducts, and pipes, from the facility when no longer in use. The facility may, however, leave an existing damper that is no longer required by NFPA 101 in-place and inoperable, if the damper is in a duct penetration of a smoke barrier in a fully ducted heating, ventilating, and air conditioning system; the damper is permanently secured in the open position; and quick-response sprinklers have been provided for the smoke compartments on both sides of the smoke barrier.(u) In operations where there is a chance of cross-contamination, clean and soiled operations must be separated to lessen the chance of cross-contamination by facility employees, residents, and others. This separation must be in relation to traffic flow, air currents, air exhaust, water flow, vapors, and other conditions.(v) A facility must have and implement as necessary a fire safety plan that:(1) includes the provisions described in the Operating Features section of NFPA 101, Chapter 18 New Health Care Occupancies and Chapter 19, Existing Health Care Occupancies and concerning:(A) use of alarms;(B) transmission of alarms to fire department;(C) emergency phone call to fire department;(D) response to alarms;(E) isolation of fire;(F) evacuation of immediate area;(G) evacuation of smoke compartment;(H) preparation of floors and building for evacuation; and(I) extinguishment of fire;(2) includes procedures for:(A) conducting a fire drill on each work shift at least once per quarter with at least one fire drill conducted each month; and(B) completing the most current version of the required HHSC form titled "Fire Drill Report" available on the HHSC website for each fire drill conducted.(w) Floors, walls, and ceilings.(1) Floors of the facility must be level, smooth, and free of any irregularities that might affect safety.(2) Walls and ceilings not specifically described elsewhere in this chapter must be cleanable, maintained attractively, and in good repair.(3) Walls and floors must be kept free of cracks. The joint between the walls and floors is to be maintained so as to be free of spaces that might harbor insects, rodents, or vermin.(x) All gas heating systems must be checked annually for proper operation and safety by persons who are licensed or approved by the State of Texas to inspect such equipment. A record of this service must be maintained by the facility. Any unsatisfactory condition must be corrected promptly.(y) A facility must have an annual inspection by the local fire marshal and maintain documentation of such an inspection at the facility.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 4CONSTRUCTION AND INITIAL SURVEY§554.330. Construction Procedures and Initial Survey of Completed Construction.(a) Construction phase.(1) Prior to the start of construction of a new facility or of building rehabilitation other than that classified as repair in §554.350§19.350 of this subchapter (relating to Building Rehabilitation), a facility must notify HHSC in Austin, Texas, in writing.(2) All construction must be done according to the minimum licensing requirements in this subchapter. It is a facility’s responsibility to employ qualified personnel to prepare the contract documents for construction of a new facility or rehabilitation of an existing facility. Contract documents for additions and rehabilitation other than that classified as repair or renovation in §554.350§19.350 of this subchapter and for the construction of an entirely new facility must be prepared by an architect licensed by the Texas Board of Architectural Examiners. Drawings must bear the seal of the architect. Certain parts of contract documents, including final plans, designs, and specifications, must bear the seal of a licensed professional engineer approved by the Texas Board of Professional Engineers to operate in Texas or, as permitted by subsections (b)(12) and (15) of this section, signed by a Responsible Managing Employee or Alarm Planning Superintendent licensed by the State Fire Marshal’s Office. These certain parts include sheets and sections covering structural, electrical, mechanical, sanitary, and civil engineering.(b) Contract documents.(1) Site plan documents must include grade contours; streets, with names; a north arrow; fire hydrant locations; fire lanes; utilities, public or private; fences; unusual site conditions, such as ditches, low water levels, and other buildings on-site; and indications of buildings located five feet or less beyond site property lines. Site plan documents for nursing facilities may include the developed landscaping plan for resident use.(2) Foundation plan documents must include the general foundation design and details.(3) Floor plan documents must include room names, numbers, and usages; resident care areas; numbered doors, including swing; windows; a legend or clarification of wall types; dimensions; fixed equipment; plumbing fixtures; kitchen basic layout; and identification of all smoke barrier walls and fire walls, outside wall to outside wall.(4) For new construction, additions to or rehabilitation of an existing building, an overall plan of the entire building must be drawn or reduced to fit on an 8 1/2-inch by 11-inch sheet.(5) Schedules must include door materials, sizes, and types; window materials, sizes, and types; room finishes; and special hardware.(6) Elevations must include exterior elevations with material note indications, and interior elevations, where needed for special conditions.(7) Roof plans must include any roof top equipment, roof slopes, drain locations, and gas piping.(8) Details must include wall sections as needed, especially for special conditions; cabinets and built-in work, basic design only; cross sections through buildings as needed; and miscellaneous details and enlargements as needed.(9) Building structure documents must include structural framing layout and details, primarily for columns, beams, joists, and structural frames; roof framing layout, when this cannot be adequately shown on cross section; cross sections in quantity and detail to show sufficient structural design; and structural details as necessary to ensure adequate structural design.(10) Electrical documents must include electrical layout, including lights, convenience outlets, equipment outlets, switches, and other electrical outlets and devices; service, circuiting, distribution, and panel diagrams; exit signs and emergency egress lighting; emergency electrical provisions, such as generators and panelboards; fire alarms and similar systems, such as control panels, devices, and alarms; staff communication systems, including a nurse call system; and sizes and details sufficient to ensure safe and properly operating systems.(11) Plumbing documents must include plumbing layout with pipe sizes and details sufficient to ensure safe and properly operating systems, water systems, sanitary systems, gas systems, other systems normally considered under the scope of plumbing, fixtures, and provisions for combustion air supply.(12) Heating, ventilation, and air-conditioning (HVAC) documents must include sufficient details of HVAC systems and components to ensure a safe and properly operating installation including, heating, ventilating, and air-conditioning layout; ducts; protection of duct inlets and outlets; combustion air; piping; exhausts; duct smoke detectors; fire dampers; and equipment types, sizes, and locations.(13) Fire sprinkler system plans and hydraulic calculations must be designed in accordance with the applicable sections of NFPA 13, and signed by a Responsible Managing Employee, licensed by the State Fire Marshal's Office, or sealed by a licensed professional engineer.(14) Other layouts, plans, or details that are necessary to convey a clear understanding of the design and scope of the project, including plans covering private water or sewer systems, which must be reviewed by the local health or wastewater authority having jurisdiction.(15) Specifications must include installation techniques, quality standards, manufacturers, references to specific codes and standards, design criteria, special equipment, hardware, finishes, and any other information needed to amplify drawings and notes.(16) Fire detection and alarm system working plans must be designed according to the applicable sections of NFPA 72 and NFPA 70 and signed by an Alarm Planning Superintendent licensed by the State Fire Marshal's Office, or sealed by a licensed professional engineer.(c) Initial survey of completed construction.(1) Upon completion of construction of a new facility, or building rehabilitation other than that classified as repair or renovation in §554.350§19.350 of this subchapter, a final construction inspection or of the facility, including grounds, basic equipment and furnishings, must be performed by HHSC prior to occupancy. The completed construction must have the written approval of the local authorities having jurisdiction, including the fire marshal and building official. When construction or building rehabilitation does not alter the licensed capacity of a facility, based on submitted documentation and the scope of the performed building rehabilitation, HHSC may permit a facility to use the rehabilitated portion of a facility pending a final construction inspection or may determine a final construction inspection is not required.(2) An applicant may obtain the inspection described in paragraph (1) of this subsection on an expedited basis. An applicant may obtain a Life Safety Code inspection within 15 business days after HHSC receives a written request if the applicant submits:(A) a complete application as required in §554.201§19.201(b) of this chapter (relating to Criteria for Licensing) and §554.204§19.204 of this chapter (relating to Application Requirements); and(B) the appropriate Life Safety Code fee listed in §554.220§19.220 of this chapter (relating to Expedited Life Safety Code and Physical Plant Inspection Fees).(3) After the completed construction is surveyed and found acceptable by HHSC, this information is conveyed to the licensing officer as part of the information needed to issue a license to the facility. Additions to or rehabilitation of existing facilities may require a revision or modification to an existing license. The building, including basic furnishings and operational needs, grades, drives, parking, and grounds must be 100 percent 100% complete at the time of this initial survey visit for HHSC to approve occupancy and licensing. A facility may accept up to three residents between the time it receives initial approval from HHSC and the time the license is issued.(4) A copy of the following documents must be provided to HHSC at the time of the survey of the completed building. HHSC may request some or all of these documents prior to scheduling the initial survey:(A) written approval of local authorities as called for in paragraph (1) of this subsection;(B) record drawings of the fire detection and alarm system as installed, signed by an Alarm Planning Superintendent licensed by the State Fire Marshal's Office or sealed by a licensed professional engineer, including a sequence of operation, the owner's manuals and the manufacturer's published instructions covering all system equipment, a signed copy of the State Fire Marshal's Office Fire Alarm Installation Certificate, and, for software-based systems, a record copy of the site-specific software, excluding the system executive software or external programmer software, in a non-volatile, non-erasable, non-rewritable memory;(C) documentation of materials used in the building that are required to have a specific limited fire resistance or flame spread rating, including special wall finishes or floor coverings; flame retardant curtains, including cubicle curtains; and fire resistance-rated ceilings. This documentation must include a signed letter from the installer verifying the material installed, such as carpeting, is the same material named in the documented fire test;(D) record drawings of the fire sprinkler system as installed, signed by a Responsible Managing Employee licensed by the State Fire Marshal's Office, or sealed by a licensed professional engineer, including the hydraulic calculations, alarm configuration, Contractor's Material and Test Certificates for Aboveground and Underground Piping, and all literature and instructions provided by the manufacturer describing the proper operation and maintenance of all equipment and devices in accordance with NFPA 25;(E) service contracts for maintenance and testing of systems, including alarm systems and sprinkler systems;(F) a copy of gas pressure test results of all facility gas lines from the meter to gas-fired equipment and appliances;(G) a written statement from an architect or engineer certifying the building was constructed to meet NFPA 101 all locally applicable codes, and that the facility substantially conforms to the minimum licensing requirements; and(H) the contract documents specified in subsection (b) of this section; and.(I) copies of reduced size floor plans on 8 1/2 by 11 inch sheets for record and file use by HHSC and for the facility to use in evacuation planning and fire alarm zone identification. Plans must contain basic legible information such as overall dimensions, room usage names, actual bedroom numbers, doors, windows, and any other pertinent information.(d) Non-approval of new construction.(1) If, during the survey of completed construction, the surveyor finds basic requirements not met, HHSC will not license the facility or approve it for occupancy. Such basic items may include the following:(A) construction that does not meet minimum code or licensure standards for basic requirements such as corridor widths that are less than eight feet clear width, ceilings installed at less than the minimum seven feet six inches height above the floor, resident bedroom dimensions less than the required minimum dimensions, and other similar features that would disrupt or otherwise adversely affect the residents and staff if corrected after occupancy;(B) absence of written approval by local authorities;(C) fire protection systems that are not completely installed or not functioning properly, including fire alarm systems, emergency power and lighting, and sprinkler systems;(D) required exits that are not usable according to NFPA 101 requirements;(E) telephones that are not installed or not working properly;(F) sufficient basic furnishings, essential appliances and equipment that are not installed or are not functioning; and(G) any other basic operational or safety feature that the surveyor, as the authority having jurisdiction, encounters that in his judgment would preclude safe and normal occupancy by residents on that day.(2) If the surveyor encounters deficiencies that do not affect the health and safety of the residents, licensure may be recommended based on an approved written plan of correction by the facility's administrator.(3) A facility must submit copies of reduced size floor plans on 8 1/2 inch by 11 inch sheets to HHSC for record and file use and for the facility to use in evacuation planning and fire alarm zone identification. Plans must contain basic legible information such as overall dimensions, room usage names, actual bedroom numbers, doors, windows, and any other pertinent information.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 5FACILIITES LICENSED ON OR AFTER SEPTEMBER 11, 2003 AND BEFORE APRIL 2, 2018§554.332. Location and Site.(a) Any conditions considered to be a fire, safety, or health hazard will be grounds for disapproval of a site by HHSC. New facilities may not be built in an area designated as a floodplain of 100 years or less.(b) Site grades must provide for positive surface water drainage so that there will be no ponding or standing water on the designated site. This does not apply to local government requirements for engineered controlled run-off holding ponds.(c) Exit doors from the building must not open directly onto a drive for vehicular traffic, but must be set back at least six feet from the edge of the drive, measured from the end of the building wall in the case of a recessed door, to prevent accidents due to lack of visual warning.(d) Walks must be provided as required from all exits and must be of non-slip surfaces free of hazards. Walks must be at least 48 inches wide except as otherwise approved. Ramps should be used in lieu of steps where possible for individuals with a disability and to facilitate bed or wheelchair removal in an emergency.(e) Outdoor activity, recreational, and sitting spaces must be provided and appropriately designed, landscaped, and equipped. Some shaded or covered outside areas are needed. These areas must be designed to accommodate residents in wheelchairs.(f) Each facility must have parking space to satisfy the needs of residents, employees, staff, and visitors. In the absence of a formal parking study, each facility must provide for a ratio of at least one parking space for every four beds in the facility. This ratio may be reduced slightly in areas convenient to public parking facilities. Space must be provided for emergency and delivery vehicles. No parking space may block or inhibit egress from the outside exit doors. Parking spaces and drives must be at least ten feet away from windows in bedrooms, dining, and living areas.(g) Barriers must be provided for resident safety from traffic or other site hazards by the use of appropriate methods such as fences, hedges, retaining walls, railings, or other landscaping. These barriers must not inhibit the free emergency egress to a safe distance away from the building.(h) Auxiliary buildings located within 20 feet of the main building must meet the applicable NFPA 101 requirements for separation and construction.(i) Other buildings on the site must meet the appropriate occupancy section or separation requirements of NFPA 101.(j) Fire service and access must be as follows:(1) The facility must be served by a paid or volunteer fire department. The fire department must provide written assurance to HHSC that the fire department can respond to an emergency at the facility within an appropriately prompt time for the travel conditions involved.(2) The facility must be served by an adequate water supply that is satisfactory and accessible for fire department use as determined by the fire department serving the facility and by HHSC.(3) There must be at least one readily accessible fire hydrant located within 300 feet of the building. The hydrant must be on a minimum six inch service line, or else there must be an approved equivalent, such as a storage tank. The hydrant, its location, and service line, or equivalent must be as approved by the local fire department and HHSC.(4) The building must have suitable all-weather fire lanes for access as required by local fire authorities and HHSC. As a minimum, there must be access to two sides of the building by an all-weather lane.(k) Enclosed exterior spaces, such as fenced areas, that are in a means of egress to a public way must meet the requirements of §554.2208(a)(6)§19.2208(a)(6) of this chapter (relating to Standards for Certified Alzheimer's Facilities).§554.336. Smoke Compartmentation (Subdivision of Building Spaces).(a) Smoke compartmentation must be as described in NFPA 101 andthe Life Safety Code and in this section.(b) An exit sign must be provided on each side of corridor smoke doors unless otherwise directed HHSCby the Texas Department of Human Services (DHS).(c) The metal frames for the wire glass view panels in smoke doors must be steel, unless otherwise approved by HHSCDHS. The bottom of the view panel must not be higher than 54 inches above the floor. Pairs of opposite (double egress) swinging smoke doors in corridors must have push/pull hardware. The door leaves must align in the closed position.(d) Smoke barrier walls in concealed spaces such as attics, must have prominent signs on each side that read: “Warning: Smoke/fire barrier. Properly seal all openings.”(e) Provisions must be made for reasonable access to concealed smoke barrier walls for maintaining smoke dampers and so that walls and dampers can be visually checked periodically for conformance by facility staff, service persons, and inspectors. Access must provide for visual inspection of both sides of the wall, and of all parts (end-to-end and top-to-bottom). Ceiling access panels must be prefabricated metal panel, or its equivalent, and be at least 20 inches by 20 inches with no obstructions above (such as ducts) to hamper entrance, and it must be fire rated if required to maintain ceiling-roof or ceiling-floor fire rating. Access must be provided for both sides of the wall.(f) Air systems should be designed to avoid having ducts which penetrate smoke barrier walls, thus eliminating the need for smoke dampers which are often a problem to maintain in proper working condition.§554.337. Fire Protection Systems.(a) Fire protection systems include detection, alarm, and communication systems; fixed automatic extinguishment systems; and portable extinguishers. These systems must meet the requirements of NFPA 101the Life Safety Code, and of this section. Components must be compatible and laboratory listed for the use intended. (b) Fire protection systems must meet the requirements of all applicable NFPA National Fire Protection Association (NFPA) standards, such as NFPA 72 for alarm systems, as referenced in NFPA 101the Life Safety Code. Wiring and circuitry for alarm systems must meet the applicable requirements of NFPA standards including the NFPA 70 for these systems.(c) Requirements of emergency electrical systems must be in accordance with §554.341§19.341 of this chaptertitle (relating to Electrical Requirements). Requirements for sprinkler systems must be in accordance with §554.340(4)§19.340(4) of this chaptertitle (relating to Mechanical Requirements).(d) Partial sprinkler systems (those provided only for hazardous areas) must be interconnected with the fire alarm and comply with NFPA 101the Life Safety Code. Each partial system must have a valve with a supervisory switch to sound a trouble signal, water flow switch to activate the fire alarm, and an end-of-line test drain.(e) Fire alarm systems must be installed, maintained, and repaired by an agent having a current certificate of registration with the State Fire Marshal's office of the Texas Commission on Fire Protection, in accordance with state law. A fire alarm installation certificate must be provided as required by the Office of the State Fire Marshal.(f) The fire alarm system must be designed so that whenever the general alarm is sounded by activation of any device (such as manual pull, smoke sensor, sprinkler, or kitchen range hood extinguisher), the following must occur automatically:(1) smoke and fire doors which are held open by approved devices must be released to close;(2) air handlers (air conditioning orand/or heating distribution fans) serving three or more rooms or any means of egress must shut down immediately;(3) smoke dampers must close; and(4) the alarm-initiating-device location must be clearly indicated on the fire alarm control panel(s) and all auxiliary panels.(g) Fire alarm bells or horns must be located throughout the building for audible coverage. Flashing alarm lights (visual alarms) must be installed to be visible in corridors and public areas including dining rooms and living rooms in a manner that will identify exit routes.(h) A master control panel indicating the location of all alarm, trouble, and supervisory signals, by zone or device, must be visible at the main nurse station. Fire alarm system components must be laboratory-listed as compatible. Alarm and trouble zoning must be by smoke compartments and by floors in multi-story facilities.(i) Remote annunciator panels, indicating location of alarm initiation, by zone or device, and trouble indication, must be located at auxiliary or secondary nurse stations on each floor, and will indicate the alarm condition of adjacent zones and the alarm conditions at all other nurse stations.(j) Manual pull stations must be provided at all exits, living rooms, dining rooms, and at or near the nurse stations.(k) The sprinkler system must be monitored for flow and tamper conditions by the fire alarm system.(l) The kitchen range hood extinguisher must be interconnected with the fire alarm system. This interconnection may be a separate zone on the panel or combined with other initiating devices located in the same zone as the range hood is located.(m) Portable fire extinguishers must be provided throughout the facility as required by NFPA Standard 10 and as determined by the local fire department and the Texas Department of Human Services. The following requirements are applicable to fire extinguishers:(1) Extinguishers in resident corridors must be spaced so that travel distance is not more than 75 feet. The minimum size of extinguishers must be either 2 1/2 gallon for water type or 5 pound for ABC type.(2) Extinguishers must be installed on hangers or brackets supplied or mounted in approved cabinets. Recessed cabinets are required for extinguishers located in corridors.(3) Extinguishers installed under conditions where they are subject to physical damage must be protected from impact or dislodgement.(4) Extinguishers having a gross weight not exceeding 40 pounds must be installed so that the top of the extinguisher is not more than five feet above the floor. Extinguishers having a gross weight greater than 40 pounds must be installed so that the top of the extinguisher is not more than 3-1/2 feet above the floor. In no case may the clearance between the bottom of the extinguisher and the floor be less than four inches.(5) Portable extinguishers provided in hazardous rooms should be located as close as possible to the exit door opening and nearest the latch (knob) side.§554.339. Structural Requirements.(a) Every building and every portion thereof must be designed and constructed to sustain all dead and live loads in accordance with accepted engineering practices and standards.(b) Special provisions must be made in the design of buildings in regions where local experience shows loss of life or extensive damage to buildings resulting from hurricanes, tornadoes, earthquakes, or floods.(c) The sponsor is responsible for employing qualified personnel in the preparation of plan designs and engineering and in the construction of the facility to assure that all structural components are adequate, safe, and meet the applicable construction requirements.(d) The design of the structural system must be done by or under the direction of a professional structural engineer who is currently registered by the Texas State Board of Registration for Professional Engineers in accordance with state law.(e) The parts of the plans, details, and specifications covering the structural design must bear the legible seal of the engineer on the original drawings from which the prints are made.(f) If the municipality has a building code, that code must govern the building requirements for the construction involved. NFPA 101The Life Safety Code must be used for fire safety requirements. Should discrepancies between the codes arise, they must be called to the attention of HHSCthe Texas Department of Human Services for resolution.(g) In the absence of a local building code, a nationally recognized building code must be used with regard to the construction integrity of the building. NFPA 101The Life Safety Code must be used for fire safety requirements.(h) Each building must be classified as to building construction type for fire resistance rating purposes in accordance with NFPA 220 and NFPA 101.the National Fire Protection Association (NFPA) 220 and the Life Safety Code.(i) Enclosures of vertical openings between floors must meet NFPA 101the Life Safety Code.(j) All interior walls, partitions, and roof structure in buildings of fire resistive and noncombustible construction must be of noncombustible or limited combustible materials.(k) Building insulation materials, unless sealed on all sides and edges in an approved manner, must have a flame spread rating of 25 or less when tested in accordance with NFPA 255 and NFPA 258.§554.340. Mechanical Requirements.The design of the mechanical systems must be done by or under the direction of a registered professional (mechanical) engineer approved by the Texas State Board of Registration for Professional Engineers to operate in Texas, and the parts of the plans and specifications covering mechanical design must bear the legible seal of the engineer. Building services pertaining to utilities; heating, ventilating, and air-conditioning systems; vertical conveyors; and chutes must be in accordance with NFPA 101the Life Safety Code. Required plumbing fixtures must be in accordance with NFPA 101the Life Safety Code and §554.334§19.334 of this chaptertitle (relating to Architectural Space Planning and Utilization) in specific use areas.(1) Plumbing. (A) All plumbing systems must be designed and installed in accordance with the requirements of the plumbing code of the municipality. In the absence of a municipal code, a nationally recognized plumbing code must be used. Any discrepancy between an applicable code and these requirements must be called to the attention of HHSCthe Texas Department of Human Services (DHS) for resolution.(B) Supply systems must assure an adequacy of hot and cold water. An average rule-of-thumb design for hot water for resident usage (at 110 degrees Fahrenheit) is to provide 6-1/2 gallons per hour per resident in addition to kitchen and laundry use.(C) Water supply must be from a system approved by TCEQ the Water Utility Division, Texas Natural Resources Conservation Commission, or from a system regulated by an entity responsible for water quality in that jurisdiction as approved by TCEQthe Water Utility Division, Texas Natural Resources Conservation Commission.(D) The sewage system must connect to a system permitted by TCEQ the Watershed Management Division, Texas Natural Resources Conservation Commission, or to a system regulated by an entity responsible for water quality in that jurisdiction as approved by TCEQthe Water Utility Division, Texas Natural Resources Conservation Commission.(E) The minimum ratio of fixtures to residents shall be as required in §554.334(c)§19.334(c) of this chaptertitle (relating to Architectural Space Planning and Utilization).(F) For design calculation purposes, resident-use hot water must not exceed 110 degrees Fahrenheit at the fixture. For purposes of conforming to licensure requirements, an operating system providing water from 100 degrees Fahrenheit to 115 degrees Fahrenheit is acceptable. Hot water for laundry and kitchen use must be normally 140 degrees Fahrenheit except that dish sanitizing, if done by hot water, must be 180 degrees Fahrenheit.(G) Water closets raised to provide a seat height 17 inches to 19 inches from the floor is required for persons with disabilities.(H) Showers for wheelchair residents must not have curbs. Tub and shower bottoms must have a slip-resistant surface. Shower and tub enclosures, other than curtains, must be of tempered glass, plastic, and other safe materials.(I) Drinking fountains must not extend into exit corridors.(J) Fixture controls easily operable by residents must be provided (such as lever type).(K) Plumbing fixtures for residents must be vitreous china or porcelain finished cast iron or steel unless otherwise approved by HHSCDHS. Bathing units constructed of class B fire rated fiberglass are acceptable for use.(L) Hand-washing sinks for staff use are required in many areas throughout the facility in accordance with §554.334§19.334 of this chaptertitle (relating to Architectural Space Planning and Utilization). Lavatories are required to be provided adjacent to water closets in each area.(M) The soiled utility room must be provided with a flushing device such as a water closet with bedpan lugs, a spray hose with a siphon breaker or similar device, such as a high neck faucet with lever controls and a deep sink that is large enough to submerse a bedpan. A sterilizer for sanitizing may be used in place of a deep sink.(N) Siphon breakers or back-flow preventers must be installed with any water supply fixture where the outlet or attachments may be submerged.(O) Clean-outs for waste piping lines must be provided and located so that there is the least physical and sanitary hazard to residents. Where possible, clean-outs must open to the exterior or areas which would not spread contamination during clean-out procedures.(P) All boilers not exempted by the Texas Health and Safety Code §755.022 must be inspected and certified for operation by The Texas Department of Licensing and Regulation.(2) Heating, ventilating, and air-conditioning systems.(A) Heating, ventilating, and air-conditioning systems must be designed and installed in accordance with the Heating, Ventilating, and Air-Conditioning Guide of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), except as may be modified by this section.(B) Heating, ventilating, and air-conditioning systems must meet the requirements of NFPA 101 and NFPA 90Athe Life Safety Code and the National Fire Protection Association (NFPA) 90A. The plans must have a statement verifying that the systems are designed to conform to NFPA 90A. Requirements for conditions related to smoke compartmentation must be in accordance with §554.336§19.336 of this chaptertitle (relating to Smoke Compartmentation (Subdivision of Building Spaces)).(C) Systems using liquefied petroleum gas fuel must meet the requirements of the Railroad Commission of Texas and NFPA 58 Liquefied Petroleum Gases.(D) The heating system must be designed, installed, and functioning to be able to maintain a temperature of at least 75 degrees Fahrenheit for all areas occupied by residents. For all other occupied areas, the indoor design temperature must be at least 72 degrees Fahrenheit. The cooling system must be designed, installed, and functioning to be able to maintain a temperature of not more than 78 degrees Fahrenheit. A facility constructed or licensed after January 1, 2004, must have a central air conditioning system, or a substantially similar air conditioning system, that is capable of maintaining a temperature suitable for resident comfort within areas used by residents. Occupied areas generating high heat, such as kitchens, must be provided with a sufficient cool air supply to maintain a temperature not exceeding 85 degrees Fahrenheit at the five-foot level. Supply air volume must be approximately equal to the air volume exhausted to the exterior for these areas.(E) Air systems must provide for mixing at least 10 percent 10% outside air for the supply distribution. Blowers for central heating and cooling systems must be designed so that they may run continuously.(F) Floor furnaces, unvented space heaters, and portable heating units must not be used. Heating devices or appliances must not be a burn hazard (to touch) to residents.(G) A combustion fresh air inlet must be provided to all gas or fossil fuel operated equipment in steel ducts or passages from outside the building in accordance with NFPA 54. Rooms must also be vented to the exterior to exhaust heated ambient air in the room. Combustion air will require one vent within 12 inches of the floor and one vent within 12 inches of the ceiling.(H) The location and design of air diffusers, registers, and return air grilles, must ensure that residents are not in harmful or excessive drafts in their normal usage of the room.(I) In areas requiring control of sanitation, the air flow must be from the clean area to the dirty area. Air supply to food preparation areas must not be from air which has circulated places such as resident bedrooms and baths.(J) Air from unsanitary areas such as janitors closets, soiled linen areas, utility areas, and soiled area of laundry rooms, must not be returned and recirculated to other areas.(K) Intakes for fresh outside air must be located sufficiently distant from exhaust outlets or other areas or conditions which may contaminate or otherwise pollute the incoming fresh air. Fresh air inlets must be appropriately screened to prevent entry of debris, rodents, and animals. Provision must be made for access to such screens for periodic inspection and cleaning to eliminate clogging or air stoppage (see paragraph (3)(C)(i) of this subsection).(L) Systems must be designed as much as possible to avoid having ducts passing through fire walls or smoke barrier walls. All openings or duct penetrations in these walls must be provided with approved automatic dampers. Smoke dampers at smoke partitions must close automatically upon activation of the fire alarm system to prevent the flow of air or smoke in either direction.(M) Ducts with smoke dampers must have maintenance panels for inspections. The maintenance panels must be removable without tools. Means of access must also be provided in the ceiling or side wall to facilitate smoke damper inspection readily and without obstruction. Location of dampers must be identified on the wall or ceiling of the occupied area below.(N) Fusible links are not approved for smoke dampers.(O) Central air supply systems and/or systems serving means of egress must automatically and immediately shut down upon activation of the fire alarm system. (An exception must be approved, engineered smoke-removal systems.)(P) Ducts must be of metal or other approved noncombustible material. Cooling ducts must be insulated against condensation drip.(3) Ventilating and exhaust.(A) General ventilating systems must be in accordance with paragraph (2) of this subsection.(B) Provisions for natural ventilation using windows or louvers must be incorporated into the building design where possible and practical. These windows or louvers must have insect screens.(C) All air-supply and air-exhaust systems must be mechanically-operated. The ventilation rates shown in the table in clause (xi) of this subparagraph must be considered as minimum acceptable rates and must not be construed as precluding the use of higher ventilation rates.(i) Outdoor air intakes must be located as far as practical (but normally not less than 10 feet) from exhaust outlets or ventilating systems, combustion equipment stacks, medical vacuum systems, plumbing vent stacks, or from areas which may collect vehicular exhaust and other noxious fumes.(ii) The ventilation systems must be designed and balanced to provide the pressure relationship as shown in the table in clause (xi) of this subparagraph. A final engineered system air balance report will be required for the completed system to be furnished and certified by the installer.(iii) The bottoms of ventilation openings must be not less than three inches above the floor of any room.(iv) Doors protecting corridors or ways of egress must not have air transfer grilles or louvers. Corridors must not be used to supply air to or exhaust air from any room except that air from corridors may be used as make-up air to ventilate small toilet rooms, janitor's closets, and small electrical or telephone closets opening directly on corridors, provided that the ventilation can be accomplished by door undercuts not exceeding 3/4 inches.(v) All exhausts must be continuously ducted to the exterior. Exhausting air into attics or other spaces is not permitted. Duct material must be metal.(vi) All central ventilation or air-conditioning systems must be equipped with filters of sufficient efficiency to minimize dust and lint accumulations throughout the system and building including supply and return plenums and ductwork. Filters with efficiency rating of 80 percent 80% or greater (based on ASHRAE) are recommended. Filters for individual room units must be as recommended by the equipment manufacturer. Filters must be easily accessible for routine changing or cleaning.(vii) Static pressures of systems must be within limits recommended by ASHRAE and the equipment manufacturer (upstream and downstream).(viii) In geographic locations or interior room areas where extreme humidity levels are likely to occur for extended periods of time, apparatus for controlling humidity levels (preferably between 40-60 percent 40-60%) are recommended to be installed as a part of central systems and with automatic humidistat controls.(ix) Exhaust hoods, ducts, and automatic extinguishers for kitchen cooking equipment must be in accordance with NFPA 96.(x) Forced air exhaust must be provided in laundries, kitchens, and dishwashing areas to remove excess heat and moisture and to maintain air flow in the direction of clean to soiled areas.(xi) Ventilation requirements for nursing areas must be according to the following table:Figure: 40 TAC §19.340(3)(C)(ix)Area DesignationAir Movement In Relation To Adjacent AreaMinimum Total Air Changes Per HourAll Air Exhausted To OutsideDesign TemperatureResident Room--2--75/78Examination and Treatment Room--4No75/78Physical TherapyIn4No75/78Occupational Therapy--4No75/78Soiled Work or Holding RoomIn6Yes--Clean Work or Holding RoomOut4No--Toilet RoomsIn10Yes--Bath and Shower Rooms--10No75/78Janitors' ClosetsIn10Yes--(xii) With relationship to adjacent areas, a positive air pressure must be provided for clean utility rooms, clean linen rooms, and medication rooms. Conditioned supply air must be introduced into these rooms.(4) Sprinkler systems. The following requirements are applicable to sprinkler systems:(A) Sprinkler systems must be in accordance with NFPA 13 and this subchapter.(B) The design and installation of sprinkler systems must meet any applicable state laws pertaining to these systems and one of the following criteria:(i) The sprinkler system must be designed by a qualified registered professional engineer approved by the Texas State Board of Registration for Professional Engineers to operate in Texas. The engineer must supervise the installation and provide written approval of the completed installation.(ii) The sprinkler system must be planned and installed in accordance with NFPA 13 by firms with certificates of registration issued by the office of the state fire marshal that have at least one full-time licensed responsible managing employee (RME). The RME's license number and signature must be included on the prepared sprinkler drawings.(C) The approved sprinkler plans must be submitted to DHS, Architectural Section, Austin, Texas.(C) (D) Particular attention should be paid to adequate, safe, and reasonable freeze protection for all piping. The design of freeze protection should minimize the need for dependence on staff action or intervention to provide protection.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 7SMALL HOUSE AND HOUSEHOLD FACILITIES§554.345. Small House and Household Facilities.(a) This section applies to a small house or household facility that is designed to provide a non-institutional environment to promote resident-centered care. New construction of a small house or household facility, including a conversion of an existing facility, an addition to an existing facility, or rehabilitation of an existing facility, must meet the requirements of this section.(b) A small house or household facility must comply with this chapter, except it is not required to comply with a requirement in division 9 of this subchapter (relating to Facilities Licensed On or After April 2, 2018) if HHSC waives the requirement in accordance with subsection (c) of this section or if the requirement is modified by subsection (g) of this section.(c) HHSC may waive a requirement in division 9 of this subchapter if HHSC determines a waiver of the requirement would facilitate the implementation of resident-centered care. To request a waiver of a requirement, a facility must submit plans to HHSC according to §554.344§19.344 of this subchapter (relating to Plan Review). The plans must include a statement from an architect identifying which requirements the facility is requesting to be waived and explaining how the waiver would contribute to the goals of resident-centered care.(d) A small house or household facility must be designed and equipped to provide a homelike environment that promotes resident-centered care.(e) A small house or a household within a facility must:(1) have no more than 16 bedrooms as described in subsection (g)(2) (g)(3) of this section;(2) have living, dining, social, and staffing areas exclusively within and for the house or household; and(3) have a kitchen that meets the requirements in §554.354(g)(1)§19.354(g)(1) of this subchapter (relating to Architectural Space Planning and Utilization for New Facilities) or a food service area that meets the requirements of an auxiliary serving kitchen in §554.354(g)(3)§19.354(g)(3) of this subchapter, exclusively within and for the house or household.(f) A small house or household facility must be:(1) a single small house model, which is a single licensed building having no more than 16 residents that meets the licensing requirements for architectural spaces provided within the same licensed building;(2) a multiple small house model, which is a single licensed group of two or more small houses located in close proximity to each other on a single contiguous property that meets the licensing requirements for architectural spaces in each house and that may include a stand-alone central building that provides social-diversional space, a treatment area, or an administrative area; or(3) a household model, which is a single licensed building that contains one or more households having no more than 16 residents each; that may include a central area that provides social-diversional space, a treatment area, or an administrative area; and that must be arranged to avoid travel through the household by persons who are not residing in, visiting, or providing services for the household.(g) A small house or household facility must comply with the requirements in this section and is not required to request a waiver for an exception described in this subsection.(1) The outdoor activity, recreational, and sitting spaces required in §554.352(f)§19.352(f) of this subchapter (relating to Location and Site for New Facilities) must include a porch area under a roof with suitable furniture for sitting and space for wheelchairs.(2) The resident bedroom requirements in §554.354(a)§19.354(a) of this subchapter must be met, except:(A) a bedroom must be occupied:(i) by only one resident; or(ii) by two residents, if they are members of the same family and the bedroom size, furniture, and headboard wall requirements for double occupancy are met;(B) the toilet requirements in §554.354(a)(7)§19.354(a)(7) of this subchapter must be met, except a bathroom must serve no more than one resident room and must include a lavatory, toilet, and a shower or bathing unit;(C) the night lighting requirement in §554.354(a)(5)§19.354(a)(5) of this subchapter must be met, except it must be a recessed wall mounted fixture just inside the entry door to the room and must not be obstructed by the door or furniture; and(D) the electrical receptacle requirements in §554.354(a)(6)§19.354(a)(6) of this subchapter must be met and additional receptacles must be provided to meet the requirements for Dwelling Unit Receptacle Outlets in NFPA 70.(3) The nursing service area requirements in §554.354(b)§19.354(b) of this subchapter must be met, except:(A) a nursing staff lounge is not required in a small house facility;(B) the nursing staff toilet room may also be a toilet room for:(i) kitchen staff;(ii) the public; or(iii) a general bathing room, if the toilet room opens into the general bathing room and common areas; and(C) the nourishment station may be part of the residential kitchen area.(4) Resident bathing and toilet facility requirements in §554.354(c)§19.354(c) of this subchapter must be met, except the door between a bathroom and a resident bedroom:(A) is not required to be a side-hinged swinging door;(B) may be an externally mounted by-pass door;(C) must have substantial hardware;(D) must not be equipped with a bottom door track that is a tripping hazard; and(E) if it swings open into the bedroom, must not interfere with the swing of any other door that opens into the bedroom.(5) The living area requirements in §554.354(e)§19.354(e) of this subchapter and dining room requirements in §554.354(f)§19.354(f) of this subchapter must be met, except the distance between the floor and the window sill of a window in the living or dining room must not exceed 36 inches, to allow a view to the outside from a seated position.(6) The dietary facility requirements in §554.354(g)§19.354(g) of this subchapter must be met, except a kitchen serving 16 or fewer non-employees per meal:(A) may be open to the facility in compliance with NFPA 101;(B) must meet the general food service needs of the residents;(C) must provide for the storage, refrigeration, preparation, and serving of food; for dish and utensil cleaning; and for refuse storage and removal;(D) must contain a multi-compartment sink, vegetable sink, and hand washing sink;(E) must provide a supply of hot water that, if used for sanitizing purposes is 180 degrees Fahrenheit or at the manufacturer's suggested temperature for chemical sanitizers;(F) must provide a supply of cold water;(G) must have janitorial facilities exclusively for the kitchen and located in close proximity to the kitchen;(H) must have kitchen floors, walls, and ceilings with nonabsorbent smooth finishes or surfaces that are capable of being routinely cleaned and sanitized to maintain a healthful environment;(I) must have counter and cabinet surfaces, inside and outside, with smooth, cleanable, relatively nonporous finishes; and(J) must have a toilet for the kitchen staff that is in close proximity to the kitchen and that may also be a toilet room for the public or the general bathing room.(7) The exit requirements in §554.355(3)§19.355(3) of this subchapter must be met except for fixed furniture and wheeled equipment as permitted by NFPA 101.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER DFACILITY CONTRUCTIONDIVISION 9FACILITIES LICENSED ON OR AFTER APRIL 2, 2018§554.361. Electrical Requirements for New Facilities.(a) The design of the electrical systems must be done by or under the direction of a licensed professional electrical engineer approved by the Texas Board of Professional Engineers to operate in Texas, and the parts of the plans and specifications covering electrical design must bear the legible seal of the engineer.(1) Utilities; heating, ventilating, and air-conditioning systems; vertical conveyors; and chutes must meet the requirements of NFPA 101, Chapter 9, Building Service and Fire Protection Equipment.(2) Fire protection systems, including fire alarms, must meet the requirements of §554.357§19.357 of this division (relating to Fire Protection Systems for New Facilities).(3) Lighting and outlets at resident bedrooms must meet the requirements of §554.354§19.354 of this division (relating to Architectural Space Planning and Utilization for New Facilities).(b) Electrical systems.(1) Electrical systems must meet the installation requirements of NFPA 70.(2) Electrical systems must meet the performance requirements of NFPA 99.(3) Branch circuits serving resident bedrooms must meet the requirements of NFPA 99.(4) Essential Electrical System (EES).(A) To provide electricity during an interruption of the normal electric supply, an emergency source of electricity must be provided and connected to certain circuits for lighting and power. All facilities covered by this section must comply with the EES requirements for new health care facilities in NFPA 99, based on the risk category determined by the assessment required by §554.300(i)§19.300(i) of this subchapter (relating to General Requirements).(i) If the determined risk category is Category 2, as defined in NFPA 99, the EES must meet the requirements for a Type II EES according to NFPA 99.(ii) If the determined risk category is Category 1, as defined in NFPA 99, the EES must meet the requirements for a Type I EES according to NFPA 99.(iii) A Type I EES serving a portion of a facility categorized as Category 1 risk is permitted to also serve a portion of the same facility categorized as Category 2 risk.(iv) Distribution requirements for Type I or Type II EES must be according to NFPA 99.(B) In addition to systems and devices required for the type of EES installed, the following systems and devices must be connected to the appropriate branches of the EES, according to NFPA 99:(i) illumination for the following areas:(I) means of egress, including areas immediately outside of exit doors;(II) nurses’ stations;(III) medication rooms;(IV) dining, living, and recreation rooms, including activity rooms;(V) bathing rooms not directly connected to resident bedrooms;(ii) exit signs and exit directional signs as required by NFPA 101;(iii) alarm systems, including fire alarms and alarms required for nonflammable medical gas systems, if installed;(iv) task illumination and selected receptacles at the generator set location;(v) selected duplex receptacles including receptacles in such areas in resident corridors, at each resident bed location, in nurses’ stations, and in medication rooms, including biologicals refrigerator;(vi) nurse call systems;(vii) resident room night lights;(viii) a light and receptacle in an electrical room or a boiler room;(ix) elevator cab lighting, control, and communication systems;(x) all facility telephone equipment;(xi) paging or speaker systems, if intended for communication during an emergency. Radio transceivers installed for emergency use must be capable of operating for at least one hour upon total failure of both normal and emergency power.(xii) Heating Equipment to Provide Heating for Resident Bedrooms. A facility must provide heating in resident bedrooms during disruption of the normal power source unless one of the following conditions applies:(I) The outside design temperature is higher than 20 degrees Fahrenheit (-6.7 degrees Celsius);(II) The outside design temperature is lower than 20 degrees Fahrenheit (-6.7 degrees Celsius) and, when selected rooms are provided for the needs of all residents, then only such rooms need be heated.(III) The facility is served by a dual source of normal power.(xiii) A facility must provide throw-over facilities to allow the temporary operation of any elevator for the release of passengers in instances when an interruption of power would result in elevators stopping between floors.(C) The emergency lighting must be automatically in operation within ten seconds after the interruption of the normal power supply. Emergency egress lighting must not be switched.(D) Receptacles and switches connected to emergency power must have red faceplates.(E) The design and installation of emergency motor generators must be according to NFPA 37, NFPA 99, and NFPA 110.(i) Nursing facilities and contiguous or same-site facilities, such as hospitals and assisted living facilities, may be served by the same generating equipment so long as the integrity of the individual facilities’ emergency or back-up power systems is not compromised. This permission applies only to the generating equipment and not to automatic or manual transfer switches or to distribution systems.(ii) Generators must be located a minimum of three feet from a combustible exterior building finish and a minimum of five feet from a building opening, if located on the exterior of the building.(iii) A facility must provide a noncombustible protective cover or the protection recommended by the manufacturer when a generator is located on the exterior of the building.(iv) Stored fuel capacity must be sufficient for not less than four hours of required generator operation.(v) Motor generators fueled by public utility natural gas must have the capability to be switched to an alternate fuel source according to NFPA 70.(F) The wiring circuits for the EES must be kept entirely independent of all other wiring and must not enter the same race-ways, boxes, or cabinets according to NFPA 70.(G) A facility must meet the requirements for the administration of the EES, including maintenance and testing of the EES, according to the requirements of NFPA 99 for the type of EES installed, and the requirements of §554.326(d)§19.326(d) of this subchapter.(5) General Lighting Requirements. General lighting requirements are as follows:(A) All spaces occupied by people, machinery, equipment, approaches to buildings, and parking lots must have lighting.(B) All quality, intensity, and type of lighting must be adequate and appropriate to the space and all functions within the space.(C) Minimum lighting levels can be found in the Illuminating Engineering Society Lighting Handbook, latest edition, but must not be lower than the following.(i) Minimum illumination must be 20 footcandles20-foot candles in resident rooms, corridors, nurses' stations, dining rooms, lobbies, toilets, bathing facilities, laundries, stairways, and elevators. Illumination requirements for these areas apply to lighting throughout the space and are measured at approximately 30 inches above the floor anywhere in the room.(ii) Minimum illumination for over-bed reading lamps, medication-preparation or storage area, kitchens, and nurses’ station desks must be 50 footcandlesfoot candles. Illumination requirements for these areas apply to the task performed and are measured on the task.(D) A facility must provide general illumination, with provisions for reduction of light levels at night, in a nursing unit corridor.(E) A facility must provide a basket wire guard or other suitable shield to prevent breakage or contact between combustible materials and exposed incandescent light bulbs, or other high-heat generating lamps, in closets or other similar spaces.(F) Exposed incandescent or fluorescent bulbs are not permitted in food service or other areas where glass fragments from breakage may get into food, medications, linens, or utensils. A facility must protect all fluorescent bulbs with a shield or catcher to prevent bulb drop-out.(6) Receptacles or convenience outlets.(A) Receptacles in bedrooms must meet the requirements in §554.354(a)(6) §19.354(a)(7) of this division (relating to Architectural Space Planning and Utilization for New Facilities).(B) Duplex receptacles for general use must be installed in corridors spaced not more than 50 feet apart and within 25 feet of ends of corridors. A facility must provide at least one duplex receptacle with emergency electrical service in each resident corridor.(C) Receptacles must be provided with emergency electrical service for essential needs such as medication refrigerators and systems or equipment whose failure is likely to result in major injury or death to a resident.(D) Receptacles in the remainder of the building must be sufficient to serve the present and future needs of residents and equipment.(E) Location of receptacles, horizontally and vertically, should be carefully planned and coordinated with the expected designed use of furnishings and equipment to maximize their accessibility and to minimize conditions such as beds or furniture being jammed against plugs used in the outlets.(F) Exterior receptacles must be an approved waterproof type.(G) A facility must provide ground fault interruption protection at appropriate locations such as at whirlpools and other wet areas according to the NFPA 70.(c) Nurse call systems.(1) A nurse call system consists of power units, annunciator control units, corridor dome stations, emergency call stations, bedside call stations, and activating devices. The units must be compatible and laboratory listed by a nationally recognized testing laboratory for the system and use intended.(2) Each resident bedroom must be served by at least one call station and each bed must be provided with a call switch. Two call switches serving adjacent beds may be served by one call station. Each call entered into the system must activate a corridor dome light above the bedroom, bathroom, or toilet room corridor door, a visual signal at the nurses’ station which indicates the room from which the call was placed, and a continuous or intermittent continuous audible signal of sufficient amplitude to be clearly heard by nursing staff. The amplitude or pitch of the audible signal must not be such that it is irritating to residents or visitors. The system must be designed so that calls entered into the system may be canceled only at the call station. Intercom-type systems which meet this requirement are acceptable.(3) A nurse call system that provides two-way voice communication must be equipped with an indicating light at each call station which lights and remains lighted as long as the voice circuit is operating.(4) A nurse call emergency switch must be provided for resident use at each resident's toilet, bath, and shower. These switches must be usable by residents using the fixtures and by a collapsed resident lying on the floor.(5) A nurse call system must meet UL 1069 for the core system of power units, annunciator control units, corridor dome lights, emergency call stations, bedside call stations, and activating devices; and(6) An ancillary or supplemental device, including a pocket pager or other portable device, is not required to meet UL 1069.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER KNURSING SERVICES§554.1001. Nursing Services.(a) The facility must have sufficient staff with the appropriate competencies and skill sets to provide nursing and related services to assure resident safety and attain or maintain the highest practicable physical, mental, and psychosocial well-being of each resident. This is determined by resident assessments and individual comprehensive care plans and considering the number, acuity and diagnoses of the facility's resident population in accordance with the facility assessment required at §554.1931§19.1931 of this chapter (relating to Facility Assessment). Staff who have been instructed and who have demonstrated competence in the care of children must provide nursing services to children. Care and services are to be provided as specified in §554.1901§19.901 of this chapter (relating to Quality of Care).(1) Sufficient staff.(A) The facility must provide services by sufficient numbers of each of the following types of personnel on a 24-hour basis to provide nursing care to all residents in accordance with resident care plans:(i) licensed nurses, except when waived under paragraph (5) of this subsection; and(ii) other nursing personnel, including nurse aides.(B) The facility must designate a licensed nurse to serve as a charge nurse on each shift, except when waived under paragraph (5) of this subsection.(C) The facility must ensure that licensed nurses have the specific competencies and skill sets necessary to care for a resident's needs, as identified through resident assessments, and described in the comprehensive care plan.(D) The facility must provide care that includes assessing, evaluating, planning, and implementing resident comprehensive care plans and responding to a resident's needs.(2) Registered nurse.(A) The facility must use the services of a registered nurse for at least eight consecutive hours a day, seven days a week, except when waived under paragraph (5) or (6) of this subsection.(B) The facility must designate a registered nurse to serve as the director of nursing on a full-time basis, 40 hours per week, except when waived under paragraph (6) of this subsection.(C) The director of nursing may serve as a charge nurse only when the facility has an average daily occupancy of 60 or fewer residents.(3) Proficiency of nurse aides. The facility must ensure that nurse aides are able to demonstrate competency in skills and techniques necessary to care for a resident's needs, as identified through resident assessments, and described in the resident's comprehensive care plan.(4) Requirements for facility hiring and use of nurse aides.(A) General rule. A facility must not use any individual working in the facility as a nurse aide for more than four months, on a full-time basis, unless:(i) the individual is competent to provide nursing and nursing related services; and(ii) the individual:(I) has completed a training and competency evaluation program, or a competency evaluation program approved by the state as meeting the requirements of 42 CFR §§483.151-483.154; or(II) has been deemed or determined competent as provided in 42 CFR §483.150(a) and (b).(B) Nonpermanent employees. A facility must not use on a temporary, per diem, leased, or any basis other than a permanent employee any individual who does not meet the requirements in subparagraphs (4)(A)(i) and (ii) of this paragraph.(C) Competency. A facility must not use any individual who has worked less than four months as a nurse aide in that facility unless the individual:(i) is a full-time employee in a state-approved training and competency evaluation program;(ii) has demonstrated competence through satisfactory participation in a state-approved nurse aide training and competency evaluation program, or competency evaluation program; or(iii) has been deemed or determined competent as provided in 42 CFR §483.150(a) and (b).(D) Registry Verification. Before allowing an individual to serve as a nurse aide, a facility must receive registry verification that the individual has met competency evaluation requirements and is not designated in the registry as having a finding concerning abuse, neglect or mistreatment of a resident, or misappropriation of a resident's property, unless:(i) the individual is a full-time employee in a training and competency evaluation program approved by the state; or(ii) the individual can prove that the individual has recently successfully completed a training and competency evaluation program, or competency evaluation program approved by the state and has not yet been included in the registry. A facility must follow up to ensure that such an individual actually becomes registered.(E) Multi-state registry verification. Before allowing an individual to serve as a nurse aide, a facility must seek information from every state registry, established under §1819(e)(2)(A) or §1919(e)(2)(A) of the Social Security Act, that the facility believes will include information about the individual.(F) Required retraining. If, since an individual's most recent completion of a training and competency evaluation program, there has been a continuous period of 24 consecutive months during none of which the individual provided nursing or nursing-related services for monetary compensation, the individual must complete a new training and competency evaluation program or a new competency evaluation program.(G) Regular in-service education. The facility must complete a performance review of every nurse aide at least once every 12 months, and must provide regular in-service education based on the outcome of these reviews. The in-service training must:(i) be sufficient to ensure the continuing competence of a nurse aide, but must be no less than 12 hours per year; (ii) address areas of weakness as determined in nurse aides' performance reviews and facility assessment at §554.1931§19.1931 of this chapter, and may address the special needs of a resident as determined by the facility staff;(iii) for a nurse aide providing services to an individual with cognitive impairments, address the care of the cognitively impaired; and(iv) include dementia management training and resident abuse prevention training.(H) The facility must comply with the nurse aide training and registry rules found in Chapter 55694 of this title (relating to Nurse Aides).(5) Waiver of requirement to provide licensed nurses on a 24-hour basis.(A) To the extent that a facility is unable to meet the requirements of paragraphs (1)(B) and (2)(A) of this subsection, the state may waive these requirements with respect to the facility, if:(i) the facility demonstrates to the satisfaction of HHSC that the facility has been unable, despite diligent efforts (including offering wages at the community prevailing rate for nursing facilities), to recruit appropriate personnel;(ii) HHSC determines that a waiver of the requirement will not endanger the health or safety of individuals staying in the facility;(iii) the state finds that, for any periods in which licensed nursing services are not available, a registered nurse or a physician is obligated to respond immediately to telephone calls from the facility; and(iv) the waivered facility has a full-time registered or licensed vocational nurse on the day shift seven days a week. For purposes of this requirement, the starting time for the day shift must be between 6 a.m. and 9 a.m. The facility must specify in writing the schedule that it follows.(B) A waiver granted under the conditions listed in this paragraph is subject to annual state review.(C) In granting or renewing a waiver, a facility may be required by the state to use other qualified, licensed personnel.(D) The state agency granting a waiver of these requirements provides notice of the waiver to the State Ombudsman and the protection and advocacy systems in the state for individuals with mental illness established under the Protection and Advocacy for Mentally Ill Individuals Act (42 USC Chapter 114, Subchapter I) and individuals with intellectual or developmental disabilities established under the Developmental Disabilities Assistance and Bill of Rights Act (42 USC Chapter 144, Subchapter I, Part C).(E) The nursing facility that is granted a waiver by the state notifies residents of the facility and the resident representatives of the waiver.(6) Waiver of the requirement to provide services of a registered nurse for more than 40 hours a week in a Medicare skilled nursing facility (SNF).(A) The secretary of the U.S. Department of Health and Human Services (secretary) may waive the requirement that a Medicare SNF provide the services of a registered nurse for more than 40 hours a week, including a director of nursing specified in paragraph (2) of this subsection, if the secretary finds that:(i) the facility is located in a rural area and the supply of Medicare SNF services in the area is not sufficient to meet the needs of individuals residing in the area;(ii) the facility has one full-time registered nurse who is regularly on duty at the facility 40 hours a week; and(iii) the facility either has:(I) only residents whose physicians have indicated (through physician's orders or admission notes) that they do not require the services of a registered nurse or a physician for a 48-hour period; or(II) made arrangements for a registered nurse or a physician to spend time at the facility, as determined necessary by the physician, to provide necessary skilled nursing services on days when the regular full-time registered nurse is not on duty.(B) The secretary provides notice of the waiver to the State Ombudsman and the protection and advocacy systems in the state for individuals with mental illness established under the Protection and Advocacy for Mentally Ill Individuals Act (42 USC Chapter 114, Subchapter I) and individuals with intellectual or developmental disabilities established under the Developmental Disabilities Assistance and Bill of Rights Act (42 USC Chapter 144, Subchapter I, Part C).(C) The SNF that is granted a waiver notifies residents of the facility and the resident representatives of the waiver.(D) A waiver of the registered nurse requirement under subparagraph (A) of this paragraph is subject to annual renewal by the secretary.(7) Request for waiver concerning staffing levels. The facility must request a waiver through the local HHSC Regulatory Services Division, in writing, at any time the administrator determines that staffing will fall, or has fallen, below that required in paragraphs (1) and (2) of this subsection for a period of 30 days or more out of any 45 days.(A) The following information must be included in the request:(i) beginning date when facility was or is unable to meet staffing requirements;(ii) type waiver requested (24-hour licensed nurse or seven-day-per-week R.N.);(iii) projected number of hours per month staffing reduced for 24-hour licensed nurse waiver or seven-day-per-week R.N. waiver; and(iv) staffing adjustments made due to inability to meet staffing requirements.(B) Waivers for licensed-only or certified facilities will be granted by HHSC Regulatory Services Division staff. Waivers for a Medicare SNF receive final approval from the CMS.(C) If a facility, after requesting a waiver, is later able to meet the staffing requirements of paragraphs (1) and (2) of this subsection, HHSC Regulatory Services Division staff must be notified, in writing, of the effective date that staffing meets requirements.(D) Verification that the facility appropriately made a request and notification will be done at the time of survey.(E) Amounts paid to Medicaid-certified facilities in the per diem payment to meet the staffing requirements of paragraphs (1) and (2) of this subsection may be adjusted if staffing requirements are not met.(8) Duration of waiver. Approved waivers are valid throughout the facility licensure or certification period, unless approval is withdrawn. During the relicensure or recertification survey, the determination is made for approval or denial for the next facility licensure or certification period if a waiver continues to be necessary. The facility requests a redetermination for a waiver from HHSC Regulatory Services Division staff at the time the survey is scheduled. At other times if a request is made, HHSC staff may schedule a visit for waiver determination.(9) Requirements for waiver approval. To be approved for a waiver, the nursing facility must meet all of the requirements stated in this subchapter and the requirements specified throughout this chapter. In some instances, the survey agency may require additional conditions or arrangements such as:(A) an additional licensed vocational nurse on day-shift duty when the registered nurse is absent;(B) modification of nursing services operations; and(C) modification of the physical environment relating to nursing services.(10) Denial or withdrawal of a waiver. Denial or withdrawal of a waiver may be made at any time if any of the following conditions exist:(A) requirements for a waiver are not met on a continuing basis;(B) the quality of resident care is not acceptable; or(C) justified complaints are found in areas affecting resident care.(11) Requirement that SNFs be in a rural area. A SNF (Medicare) must be in a rural area for waiver consideration, as specified in paragraph (6) of this subsection. A rural area is any area outside the boundaries of a standard metropolitan statistical area. Rural areas are defined and designated by the federal Office of Management and Budget; are determined by population, economic, and social requirements; and are subject to revisions.(b) Nurse staffing information.(1) Data requirements. The facility must post the following information:(A) on a daily basis:(i) the facility name;(ii) the current date;(iii) the resident census; and(iv) the specific shifts for the day; and(B) at the beginning of each shift, the total number of hours and actual time of day to be worked by the following licensed and unlicensed nursing staff, including relief personnel directly responsible for resident care:(i) RNs;(ii) LVNs; and(iii) CNAs.(2) Posting requirements. The nursing facility must post the data described in paragraph (1) of this subsection:(A) in a clear and readable format; and(B) in a prominent place readily accessible to residents and visitors.(3) Public access to posted nurse staffing data. The facility must, upon oral or written request, make copies of nurse staffing data available to the public for review at a cost not to exceed the community standard rate.(4) Facility data retention requirements. The facility must maintain the posted daily nurse staffing data for the period of time specified by written facility policy or for at least two years following the last day in the schedule, whichever is longer.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER MPHYSICIAN SERVICES§554.1207. Prescription of Psychoactive Medication.(a) In this section, the following words and terms have the following meanings, unless the context clearly indicates otherwise:(1) Medication-related emergency--A situation in which it is immediately necessary to administer medication to a resident to prevent:(A) imminent probable death or substantial bodily harm (emotional or physical) to the resident; or(B) imminent physical or emotional harm to another because of threats, attempts, or other acts the resident overtly or continually makes or commits.(2) Psychoactive medication--A medication prescribed for the treatment of symptoms of psychosis or other severe mental or emotional disorders and used to exercise an effect on the central nervous system to influence and modify behavior, cognition, or affective state when treating the symptoms of mental illness. The term includes the following categories when used as described by this subdivision:(A) anti-psychotics or neuroleptics;(B) antidepressants;(C) agents for control of mania or depression;(D) anti-anxiety agents;(E) sedatives, hypnotics, or other sleep-promoting drugs; and(F) psychomotor stimulants.(b) A person may not administer a psychoactive medication to a resident who does not consent to the prescription unless:(1) the resident is having a medication-related emergency; or(2) the person authorized by law to consent on behalf of the resident has consented to the prescription.(c) Consent to the prescription of psychoactive medication given by a resident, or by a person authorized by law to consent on behalf of the resident, is valid only if:(1) the consent is given voluntarily and without coercive or undue influence;(2) consent is given in writing, on a form prescribed by HHSC, by a resident or by a person authorized by law to consent on behalf of the resident;(3) the person who prescribes the medication, or that person's designee, or the facility’s medical director provides the resident and, if applicable, the person authorized by law to consent on behalf of the resident, with the following information in a single document identified as being for the purpose of consent to treatment with psychoactive medication:(A) the specific condition to be treated;(B) the beneficial effects on that condition expected from the medication;(C) the probable clinically significant side effects and risks associated with the medication, as reported in widely available pharmacy databases or the manufacturer's package insert; and(D) the proposed course of the medication;(4) (3) the resident and, if appropriate, the person authorized by law to consent on behalf of the resident, are informed in writing that consent may be revoked; and(5) (4) the consent is evidenced in the resident's clinical record by:(A) a signed form prescribed by the facility, or by a statement of the person who prescribes the medication or that person's designee that documents consent was given by the appropriate person and the circumstances under which the consent was obtained; and(B) the original or a copy of the form described in paragraph (2).(d) (A) Consent is valid until:(1) (i) consent is withdrawn; or(2) (ii) the practitioner has discontinued the medication.(e) (B) For purposes of this rule, a medication will be considered to be discontinued if therapy has been suspended for more than 70 days. If the suspended therapy is resumed within the 70-day period, an oral explanation of side effects should be documented in the clinical record.(f) (d) The Health and Safety Code, Chapter 313, Consent to Medical Treatment, provides guidance on treatment decisions when a resident is comatose, incapacitated, or otherwise mentally or physically incapable of communication. An ethics committee also may prove helpful in such situations.(g) (e) A resident's refusal to consent to receive psychoactive medication must be documented in the resident's clinical record.(h) (f) If a person prescribes psychoactive medication to a resident without the resident's consent because the resident is having a medication-related emergency:(1) the person must document the necessity of the order in the resident's clinical record in specific medical or behavioral terms; and(2) treatment of the resident with the psychoactive medication must be provided in the manner, consistent with clinically appropriate medical care, least restrictive of the resident's personal liberty.(i) (g) A physician, or a person designated by the physician, is not liable for civil damages or an administrative penalty and is not subject to disciplinary action for a breach of confidentiality of medical information for a disclosure of the information provided under subsection (c)(2) made by the resident, or the person authorized by law to consent on behalf of the resident, that occurs while the information is in the possession or control of the resident or the person authorized by law to consent on behalf of the resident.TITLE 26HEALTH AND HUMAN SERVICES PART 1TEXAS HEALTH AND HUMAN SERVICES COMMISSION CHAPTER 554NURSING FACILITY REQUIREMENTS FOR LICENSURE AND MEDICAID CERTIFICATIONSUBCHAPTER QINFECTION CONTROL§554.1601. Infection Control.(a) General. The facility must establish and maintain an infection prevention and control program designed to provide a safe, sanitary, and comfortable environment and to help prevent the development and transmission of communicable diseases and infections.(b) Infection prevention and control program (IPCP). The facility must establish an IPCP and conduct an annual review, effective November 28, 2019, of the IPCP and update the program, as necessary. The Quality Assessment and Assurance Committee, as described in §554.1917§19.1917 of this chapter (relating to Quality Assessment and Assurance) monitors the IPCP. The IPCP must include:(1) a system for preventing, identifying, reporting, investigating, and controlling infections and communicable diseases for all residents, staff, volunteers, visitors, and other individuals providing services under a contractual arrangement based upon the facility assessment conducted according to §554.1931§19.1931 of this chapter (relating to Facility Assessment), and following accepted national standards;(2) written standards, policies, and procedures for the program, which must include:(A) a system of surveillance designed to identify possible communicable diseases or infections, including multidrug-resistant organisms, before they can spread to other persons in the facility;(B) when and to whom possible incidents of communicable diseases or infections should be reported;(C) standard and transmission-based precautions to be followed to prevent spread of infections;(D) when and how isolation should be used for a resident; including:(i) the type and duration of the isolation, depending upon the infectious agent or organism involved; and(ii) a requirement that the isolation should be the least restrictive possible for the resident under the circumstances;(E) the circumstances under which the facility must prohibit employees with a communicable disease or infected skin lesions from direct contact with a resident or a resident's food, if direct contact will transmit the disease; and(F) the hand hygiene procedures to be followed by staff involved in direct resident contact;(3) an antibiotic stewardship program that includes antibiotic use protocols and a system to monitor antibiotic use;(4) procedures for making rapid influenza diagnostic tests available to facility residents;(5) (4) a system for recording incidents identified under the facility's IPCP and the corrective actions taken by the facility; and(6) (5) acceptable accommodations for a resident with a communicable disease according to current practices and policies for infection control.(c) Infection preventionist. Effective November 28, 2019, the facility must designate one or more individuals as the infection preventionist (IP) who is responsible for the facility's IPCP. The individual designated as the IP, or at least one of the individuals if there is more than one IP, must be a member of the facility's Quality Assessment and Assurance Committee and report to the committee on the IPCP on a regular basis. The IP must:(1) have primary professional training in nursing, medical technology, microbiology, epidemiology, or other related field;(2) be qualified by education, training, experience or certification;(3) work at least part-time at the facility; and(4) have completed specialized training in infection prevention and control.(d) Communicable Diseases.(1) Policies. The facility must have and implement written policies for the control of communicable diseases in employees and residents and must maintain evidence of compliance with local and state health codes and ordinances regarding employee and resident health status.(2) Reporting. The name of any resident with a reportable disease as specified in Title 25, Chapter 97, Subchapter A (relating to Control of Communicable Diseases), must be reported immediately to the city health officer, county health officer, or health unit director having jurisdiction, and appropriate infection control procedures must be implemented as directed by the local health authority.(3) Tuberculosis.(A) The facility must conduct and document an annual review that assesses the facility's current risk classification according to the current CDC Guidelines for Preventing the Transmission of Mycobacterium Tuberculosis in Health Care Settings.(B) The facility must screen all employees before providing services in the facility, according to CDC guidelines. The facility must require all persons providing services under an outside resource contract to provide evidence of a current tuberculosis screening prior to providing services in the facility. The facility must document or keep a copy of the evidence provided.(C) If the facility determines or suspects that an employee or person providing services under an outside resource contract has been exposed to or has a positive screening for a communicable disease, the facility must respond according to the current CDC guidelines and keep documentation of the action taken.(D) If the facility determines that an employee or a person providing services under an outside resource contract has been exposed to a communicable disease, the facility must conduct and document a reassessment of the risk classification. The facility must conduct and document subsequent screening based upon the reassessed risk classification.(E) The facility must screen all residents at admission in accordance with the attending physician's recommendations and current CDC guidelines. If the facility determines or suspects that a resident has been exposed to a communicable disease or has a positive screening, the facility must respond according to the current CDC guidelines and attending physician's recommendations, and keep documentation of the response.(e) Vaccinations.(1) A facility must develop and implement a written policy to protect a resident from vaccine preventable diseases in accordance with Texas Health and Safety Code, Chapter 224.(A) The policy must:(i) require an employee, contractor, or other individual with privileges providing direct care to a resident to receive vaccines for the vaccine preventable diseases specified by the facility based on the level of risk the employee, contractor, or other individual presents to residents by the employee's, contractor's, or other individual's routine and direct exposure to residents;(ii) specify the vaccines an employee, contractor, or other individual with privileges to provide direct resident care is required to receive in accordance with clause (i) of this subparagraph;(iii) include procedures for the facility to verify that an employee, contractor, or other individual with privileges to provide direct resident care has complied with the policy;(iv) include procedures for the facility to exempt an employee, contractor, or other individual with privileges to provide direct resident care from the required vaccines for the medical conditions identified as contraindications or precautions by the CDC;(v) for an employee, contractor, or other individual with privileges to provide direct resident care who is exempt from the required vaccines, include procedures the employee, contractor, or other individual must follow to protect residents from exposure to vaccine preventable diseases, such as the use of protective equipment, such as gloves and masks, based on the level of risk the employee, contractor, or other individual presents to residents by the employee's, contractor's, or other individual's routine and direct exposure to residents;(vi) prohibit discrimination or retaliatory action against an employee, contractor, or other individual with privileges to provide direct resident care who is exempt from the required vaccines for the medical conditions identified as contraindications or precautions by the CDC, except that required use of protective medical equipment, such as gloves and masks, may not be considered retaliatory action;(vii) require the facility to maintain a written or electronic record of each employee's, contractor's, or other individual's compliance with or exemption from the policy; and(viii) include disciplinary actions the facility may take against an employee, contractor, or other individual with privileges to provide direct resident care who fails to comply with the policy.(B) The policy may:(i) include procedures for an employee, contractor, or other individual with privileges to provide direct resident care to be exempt from the required vaccines based on reasons of conscience, including religious beliefs; and(ii) prohibit an employee, contractor, or other individual with privileges to provide direct resident care who is exempt from the required vaccines from having contact with residents during a public health disaster, as defined in Texas Health and Safety Code, §81.003 (relating to Definitions).(2) A facility must offer vaccinations to a resident in accordance with an immunization schedule adopted by the Advisory Committee on Immunization Practices of the CDC.(A) Pneumococcal vaccinations for residents. The facility must offer pneumococcal vaccination to a resident 65 years of age or older who has not received the vaccination and to a resident younger than 65 years of age, who has not received the vaccination but is a candidate for it because of chronic illness. A pneumococcal vaccination must be offered to a current resident of a facility and to a new resident at the time of admission. A vaccination must be completed unless a physician has indicated that the vaccination is medically contraindicated or the resident refuses the vaccination. The facility must develop and implement policies and procedures to ensure that:(i) before offering the pneumococcal immunization, each resident or resident representative receives education regarding the benefits and potential side effects of the pneumococcal vaccination;(ii) each resident is offered a pneumococcal immunization, unless the immunization is medically contraindicated or the resident has already been immunized;(iii) the resident or the resident representative has the opportunity to refuse immunization; and(iv) the resident's clinical record includes documentation that indicates:(I) that the resident or the resident representative was provided education regarding the benefits and potential side effects of pneumococcal immunization;(II) that the resident either received the pneumococcal immunization or did not receive the pneumococcal immunization due to medical contraindication or refusal; and(III) the date of the receipt or refusal of the pneumococcal vaccination.(v) Based on an assessment and practitioner recommendation, a second pneumococcal vaccination may be given five years after the first pneumococcal vaccination, unless medically contraindicated or the resident or the resident representative refuses the second vaccination.(B) Influenza vaccinations for residents and employees. The facility must offer an influenza vaccination to a resident and an employee in contact with residents, unless the vaccination is medically contraindicated by a physician or the employee or resident has refused the vaccination.(i) Influenza vaccinations for all residents and employees in contact with a resident must be completed by November 30 of each year. Employees hired or residents admitted after this date and during the influenza season (through March of each year) must receive influenza vaccinations, unless medically contraindicated by a physician or the employee, the resident, or the resident representative refuses the vaccination.(ii) The facility must develop and implement policies and procedures that ensure that:(I) before offering the influenza immunization, each resident or resident representative receives education regarding the benefits and potential side effects of the influenza vaccination; and(II) the resident's clinical record includes documentation that indicates:(-a-) that the resident or the resident representative was provided education regarding the benefits and potential side effects of influenza immunization;(-b-) that the resident either received the influenza immunization or did not receive the influenza immunization due to medical contraindications or refusal; and(-c-) the date of the receipt or refusal of the annual influenza vaccination.(C) Hepatitis B vaccinations for employees. The facility must develop a method to identify employees at risk of directly contacting blood or potentially infectious materials. The facility must offer an employee identified as being at risk of directly contacting blood or potentially infectious materials a hepatitis B vaccine within 10 days of employment. If the employee initially declines the hepatitis B vaccination but at a later date, while still at risk of directly contacting blood or potentially infectious materials, decides to accept the vaccination, the facility must make the vaccination available within 10 days after the employee decides to accept that vaccination.(f) Linens. Personnel must handle, store, process, and transport linens so as to prevent the spread of infection and in accordance with §554.325§19.325 of this chapter (relating to Linen).(g) The Quality Assessment and Assurance Committee as described in §554.1917§19.1917 of this chapter (relating to Quality Assessment and Assurance) will monitor the Infection Prevention and Control Program. ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download