Test procedure. Quidel Triage NT-proBNP 1 2 3

[Pages:2]Test procedure.

1

2

3

Add patient sample to device using the transfer pipette

Insert test device into the Quidel Triage MeterPro.

Read results on the LCD screen, print or utilise data management.

Triage System product list.

Product

Tests and Controls Quidel Triage Cardiac Panel* Quidel Triage Profiler SOBTM Panel* Quidel Triage BNP Test* Quidel Triage D-Dimer Test* Quidel Triage Total 5 Control 1 Quidel Triage Total 5 Control 2 Quidel Triage Troponin l Test* Quidel Triage Cardio2 Panel* Quidel Triage Cardio3 Panel* Quidel Triage Total 3 Control 1 Quidel Triage Total 3 Control 2 Quidel Triage NT-proBNP Test* Quidel Triage NT-proBNP Control 1* Quidel Triage NT-proBNP Control 2* Quidel Triage TOX Drug Screen* Quidel Triage TOX Drug Screen Control 1 Quidel Triage TOX Drug Screen Control 2

Cat. No.

97000HSEU 97300EU

98000XREU 98100EU 88753 88754 98600EU 97500EU 97400EU 88733 88734 98700EU 98713EU 98714EU 94400EU 94413 94414

Quantity

25 each 25 each 25 each 25 each 5 vials (5x0.25mL) 5 vials (5x0.25mL) 25 each 25 each 25 each 5 vials (5x0.25mL) 5 vials (5x0.25mL) 25 each 5 vials (5x0.25mL) 5 vials (5x0.25mL) 25 each 5 vials (5x0.25mL) 5 vials (5x0.25mL)

Instrument Quidel Triage MeterPro

*Not for distribution or sale in the U.S.

55071

1 each

1 "ESC Guidelines for Diagnosis and Treatment of Acute and Chronic Heart Failure"; European Journal of Heart Failure; 2008; 29:2388-2422 2 Hobbs F.D.R., "Clinical Burden and Health Service Challenges of Chronic Heart Failure"; European Journal of Heart Failure Supplements (2009); 8: i1-i4 3 Alere Triage NT-proBNP Test Package Insert. Data on file at Quidel 4 Moe G.W. et al., "N-Terminal Pro-B-Type Natriuretic Peptide Testing Improves the Management of Patients with Suspected Acute Heart Failure: Primary Results of

the Canadian Randomized Multicenter IMPROVE-CHF Study"; Circulation, 2007; 115: 3102-3110 5 Lewandrowski K., "Point-of-Care Testing for Cardiac Markers in Acute Coronary Syndromes and Heart Failure"; Clin Lab Med 2009; 29: 561-571 6 Alere Triage Meter-pro operation manual

? 2017 Quidel. All rights reserved.

Quidel | Rapid Diagnostics | | 800.874.1517 | 858.552.1100

SL2719EU | BR9870000EN00 (06/18)

Quidel Triage NT-proBNP Rapid treatment at the Point-of-Care

Quidel Triage NT-proBNP Test.

Used with the Quidel Triage MeterPro for the quantitative determination of N-terminal pro Brain Natriuretic Peptide (NT-proBNP) in EDTA anticoagulated whole blood and plasma specimens.

Empower heart failure treatment decisions or risk stratify Acute Coronary Syndrome at the point of care or in the laboratory.

Heart Failure (HF) is an increasingly common condition with growing prevalence due to the ageing population.1 Globally there are over 15 million patients with HF.1 HF is associated with significant morbidity and mortality, and high healthcare costs.2 Early diagnosis and proper treatment may have positive effects on HF patients' re-hospitalization and can improve their life expectancy and quality of life.2

Knowledge of circulating blood levels of NT-proBNP can aid in various clinical applications. The test can be used:4

As an aid in the diagnosis of individuals suspected of having congestive heart failure (also referred to as heart failure). As an aid for the risk stratification of patients with heart failure. As an aid for the risk stratification of patients with acute coronary syndromes (ACS). As and aid in the assessment of increased risk for cardiovascular events and mortality in patients at risk for HF who have stable coronary artery disease (CAD).

Quality results at point-of-care speed.

Measurable range: 20 ? 35,000 pg/mL Excellent Correlation vs. Reference Method3

Quidel Triage NT-proBNP vs Roche Elecsys proBNP.

Analysis showed an excellent correlation between the two methods with a coefficient of correlation r = 0.98. The area under the curve (AC) = 0.93.

Empower rapid treatment

May reduce time to decision, allowing quicker treatment initiation. May decrease patient time spent in the ED4 and length of stay.5 May reduce the number of patients rehospitalized.4 May improve clinical and financial outcomes.4,5

Easy to implement, easy to use3,6

Simple whole blood or plasma procedure. Rapid, accurate, quantitative results in approximately 20 minutes. Full connectivity to laboratory information systems (LIS) and hospital information system (HIS).

................
................

In order to avoid copyright disputes, this page is only a partial summary.