Compact I/O ASCII Module

User Manual

Compact I/O ASCII Module

Catalog Numbers 1769-ASCII

Important User Information

Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.

Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.

Throughout this manual, when necessary, we use notes to make you aware of safety considerations.

WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.

ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.

IMPORTANT Identifies information that is critical for successful application and understanding of the product.

Labels may also be on or inside the equipment to provide specific precautions.

SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present.

BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures.

ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).

Allen-Bradley, Rockwell Software, Rockwell Automation, Compact I/O, CompactLogix, Logix5000, MicroLogix, RSLogix, Studio 5000 Logix Designer, and Studio 5000 are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

New and Updated Information

Summary of Changes

This manual contains new and updated information. Changes throughout this revision are marked by change bars, as shown to the right of this paragraph.

This table contains the changes made to this revision.

Topic Rearranged content and updated warnings and attentions. Updated configuration to include the CompactLogixTM 5370 L3 controller, provided link to the Knowledgebase Technote # 64203. Added information about the Studio 5000TM environment. Updated Additional Resources. Updated configuration examples. Updated I/O Memory Mapping to include the new tag structures. Added the Generic Module appendix. Added Electronic Keying appendix. Updated Technical Support links, website addresses, and phone numbers.

Page Throughout 7

7 8 21 71 87 105 BackCover

Rockwell Automation Publication 1769-UM012B-EN-P - January 2014

3

Summary of Changes

Notes:

4

Rockwell Automation Publication 1769-UM012B-EN-P - January 2014

Table of Contents

Preface Compact I/O ASCII Module Configure the 1769-ASCII Module

I/O Memory Mapping

Studio 5000 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Example Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Chapter 1

About the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Environment and Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 North American Hazardous Location Approval . . . . . . . . . . . . . . . . . . . . 11 European Hazardous Location Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Install the Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Assemble the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Minimum Space. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Panel Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 DIN Rail Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Replace a Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ground the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Connect the D-sub Connector Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Chapter 2

Configure the 1769-ASCII Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Module Definition Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Controller-scoped Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Connect to Channel 0 of the Module in Alternating Mode . . . . . . . . . . 34 Ladder Logic Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Configure the Module Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Connect to Both Channels of the Module in Alternating Mode. . . . . . 41 Ladder Logic Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Connect to Both Channels of the 1769-ASCII Module in Simultaneous Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Ladder Logic Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Configure the Module for Use with a MicroLogix Controller . . . . . . . . 59 Programming Example: MicroLogix 1500 Controller . . . . . . . . . . . . . . . 62

Chapter 3

ASCII Module Behavior when not in Run Mode . . . . . . . . . . . . . . . . . . . 71 Alternate Mode (one channel at a time) Output File . . . . . . . . . . . . . . . . 72 Alternate Mode (one channel at a time) Input File . . . . . . . . . . . . . . . . . . 73 Simultaneous Mode (two channels) Input File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Simultaneous Mode (two channels) Output File . . . . . . . . . . . . . . . . . . . . 75

Status Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Configuration File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Configuration File Parameter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 79