TABLE 1704.1 MINIMUM SPECIAL INSPECTOR QUALIFICATIONS
[Pages:2]TABLE 1704.1 MINIMUM SPECIAL INSPECTOR QUALIFICATIONS
Category of Testing and Inspection
1704.2 Inspection of Fabricators Pre-cast Concrete
Structural Steel Construction Wood Construction
Cold Formed Metal Construction
1704.3 & 1707.2 Steel Construction
Welding High Strength Bolting, Inspection of Steel Frame Joint
Details 1704.4 & 1708.3 Concrete Construction
Reinforcing Placement, Cast-in-Place Bolts, Pre-stressing Steel installation, Concrete and Shotcrete Placement and
curing operations Erection of pre-cast concrete members
Concrete Field Testing Review certified mill reports and design mixes
Review use of Required Design Mix Pre-stressed (pre-tensioned) concrete force application
Post-tensioned concrete force application Review of in-situ concrete strength, prior to stressing post-
tensioned concrete Reinforcing steel weldability, reinforcing welding, weld
filler material 1704.5 & 1708.1 Masonry
Review f'm prior to construction Mortar joint construction, grout protection and placement, materials proportion, type/size/location of reinforcement,
structural elements, anchorage, and connectors
Sampling/Testing of Grout/Mortar specimens
Observe preparation of masonry prisms for testing of compressive strength of masonry, f'm
Inspection of welding of reinforcing steel
Minimum Qualifications (refer to key at end of Table)
Shop Inspection
Field Inspection/
Review
Review Submittals
Review Testing, Certification, & Lab Reports
A, C, D, E C, F, G A A
C, F, G
C, F, G
A
A, B
A, C
A
A, B
A, C, E
A, C, H, I
A, C, H A, I, J, H, C
A A, I, J, H, C
A, C, D A
C, F, G
A
A, C, K, L
A, C, (J + M) A, C, K, L
C, F, G
1704.7 & 1803 Soils
Observe Site Preparation and Fill Placement with Testing
of Compaction for compliance with the Geotechnical
A, I
Report for the project
Observe and Test Bearing Materials below Shallow Foundations for ability to achieve design bearing capacity
A, N
Review Compaction Testing for compliance with the Geotechnical Report for the project
A Page 1 of 2
TABLE 1704.1 MINIMUM SPECIAL INSPECTOR QUALIFICATIONS
Category of Testing and Inspection
1704.8, 1704.9 & 1807 Pile and Pier Foundations Observe Installation Observe Load Tests
1704.10 Sprayed Fire-Resistant Materials Observe surface conditions, application, average thickness
and density of applied material, and cohesive/adhesive bond
1704.11 Mastic and intumescent fire-resistant coatings Observe application compliance with AWCI 12-B
1704.12 Exterior Insulation and Finish Systems Inspect EIFS Systems
1704.13 Special Cases Work of unusual or special nature
Minimum Qualifications (refer to key at end of Table)
Shop Inspection
Field Inspection/
Review
Review Submittals
Review Testing, Certification, & Lab Reports
A, N A
A, C
A, C A, B, C, O A, B, O
1704.14 Smoke Control
See Requirements of IBC Section 1704.14.2.
1705, 1707 & 1708 Seismic and Wind Resistance
Periodic inspection of fabrication, installation and/or anchorage of building systems and components
A
KEY:
A. Georgia Professional Engineer (GA PE) competent in the specific task area or graduate of accredited engineering/engineering technology
program under the direct supervision of a GA PE.
B. Georgia Licensed Architect (GA RA) or graduate of accredited architecture/architecture technology program under the direction of a GA
RA.
C. International Code Congress (ICC) Special Inspector Certification specific to the particular material and testing methodology applicable to
each Category of Testing and Inspection listed in the table.
D. Post-tensioning Institute (PTI) Certification.
E. Pre-stressed Concrete Institute (PCI) Certified Inspector.
F. American Welding Society (AWS) Certified Welding Inspector (CWI) or AWS Certified Associate Welding Inspector working under the
direct on-site supervision of a CWI.
G. American Society for Nondestructive Testing (ASNT) Level II certification,
or Level III certification previously certified as Level II specific to the particular material and testing methodology applicable to each
Category of Testing and Inspection listed in the table.
H. American Concrete Institute (ACI) Concrete Construction Special Inspector.
I. National Institute for Certification of Engineering Technicians (NICET) Level II or III certification specific to the particular material and
testing methodology applicable to each Category of Testing and Inspection listed in the table.
J. ACI Concrete Field Testing Technician with Grade 1 certification
K. Georgia Concrete and Product Association (GC&PA) ? Masonry Association of Georgia (MAG) Masonry Construction Inspector
Certification.
L. National Concrete Masonry Association (NCMA) Concrete Masonry Testing Procedures certification.
M. GC&PA ? MAG Masonry Testing Technician certification.
N. NICET Certified Engineering Technologist (CT).
O. Other Qualified Special Inspector as approved by the Building Official.
Notes: The minimum qualifications shown are either one or the other per category (not all) unless otherwise stated. Materials testing shall be done by an Approved Testing Agency meeting the requirements of IBC Section 1703 and ASTM ? E329. The Building Official is authorized to approve Special Inspectors who have documented relevant experience and are progressing towards achieving the minimum qualifications noted above prior to January 1, 2008.
Page 2 of 2
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- indiana register fire prevention and building safety commission ceb
- chapter 10 means of egress icc
- chapter 10 means of egress massachusetts
- key changes in the 2018 international building code for georgia
- table 1704 1 minimum special inspector qualifications
- state of washington state building code council
- fire codes enforcement assembly occupancy correction list tennessee
- icc code corner 2012 ifc code commentary campus fire safety
- table 2902 1 minimum number of required plumbing fixtures see sections
- table 1004 1 2 maximum floor area allowances per occupant
Related searches
- hud handbook 4000.1 minimum standards
- hud handbook 4000 1 minimum standards
- hud 4910 1 minimum property standards
- crafting table mod 1 12 2
- crafting table mod 1 7 10
- multiplication table pdf 1 12
- time table chart 1 12 printable
- bigger crafting table mod 1 12 2
- better crafting table mod 1 12 2
- rice crafting table mod 1 12 2
- bigger crafting table mod 1 15 2
- 2015 ibc table 1004 1 2