Fabric Manager for NVIDIA NVSwitch Systems
Fabric Manager for NVIDIA NVSwitch Systems
User Guide / Virtualization / High Availability Modes
DU-09883-001_v0.7 | January 2021
DU-09883-001_v0.7
Version Date
0.1
Oct 25, 2019
0.2
Mar 23, 2020
0.3
May 11, 2020
0.4
July 7, 2020
0.5
July 17, 2020
0.6
Aug 03, 2020
0.7
Jan 26, 2021
Document History
Authors SB SB YL
SB SB SB
GT, CC
Description of Change Initial Beta Release Updated error handling and bare metal mode Updated Shared NVSwitch APIs section with new API information Updated MIG interoperability and high availability details. Updated running as non-root instructions Updated installation instructions based on CUDA repo and updated SXid error details Updated with vGPU multitenancy virtualization mode
Fabric Ma nager fo r NVIDIA NVSwitch Sy stems
DU-09883-001_v0.7 | ii
Table of Contents
Chapter 1. Overview...................................................................................................... 1 1.1 Introduction.............................................................................................................1 1.2 Terminology ............................................................................................................1 1.3 NVSwitch Core Software Stack.................................................................................2 1.4 What is Fabric Manager?..........................................................................................3
Chapter 2. Getting Started With Fabric Manager ...................................................... 5 2.1 Basic Components...................................................................................................5 2.2 NVSwitch and NVLink Initialization ...........................................................................5 2.3 Supported Platforms................................................................................................6 2.4 Supported Deployment Models.................................................................................6 2.5 Other NVIDIA Software Packages .............................................................................6 2.6 Installation ..............................................................................................................7 2.7 Managing Fabric Manager Service............................................................................7 2.8 Fabric Manager Startup Options...............................................................................8 2.9 Fabric Manager Service File.....................................................................................9 2.10 Running Fabric Manager as Non-Root......................................................................9 2.11 Fabric Manager Config Options ..............................................................................11
Chapter 3. Bare Metal Mode ...................................................................................... 19 3.1 Introduction...........................................................................................................19 3.2 Fabric Manager Installation ...................................................................................19 3.3 Runtime NVSwitch and GPU errors ........................................................................19 3.4 Interoperability With MIG........................................................................................21
Chapter 4. Virtualization Models ............................................................................... 23 4.1 Introduction...........................................................................................................23 4.2 Supported Virtualization Models.............................................................................23
Chapter 5. Fabric Manager SDK................................................................................ 25 5.1 Data Structures.....................................................................................................25 5.2 Initializing FM API interface....................................................................................28 5.3 Shutting Down FM API interface.............................................................................28 5.4 Connect to Running FM Instance............................................................................28 5.5 Disconnect from Running FM Instance...................................................................29 5.6 Getting Supported Partitions..................................................................................29 5.7 Activate a GPU Partition.........................................................................................30 5.8 Activate a GPU Partition with VFs ...........................................................................30
Fabric Ma nager fo r NVIDIA NVSwitch Sy stems
DU-09883-001_v0.7 | iii
5.9 Deactivate a GPU Partition.....................................................................................31 5.10 Set Activated Partition List after Fabric Manager Restart ........................................32 5.11 Get NVLink Failed Devices......................................................................................32 5.12 Get Unsupported Partitions....................................................................................33
Chapter 6. Full Passthrough Virtualization Model .................................................. 34 6.1 Supported VM Configurations.................................................................................36 6.2 Virtual Machines with 16 GPUs...............................................................................36 6.3 Virtual Machines with 8 GPUS ................................................................................36 6.4 Virtual Machines with 4 GPUS ................................................................................36 6.5 Virtual Machines with 2 GPUs.................................................................................37 6.6 Virtual Machine with 1 GPU....................................................................................37 6.7 Other Requirements ..............................................................................................37 6.8 Hypervisor Sequences............................................................................................37 6.9 Monitoring Errors..................................................................................................38 6.10 Limitations ............................................................................................................38
Chapter 7. Shared NVSwitch Virtualization Model .................................................. 39 7.1 Software Stack ......................................................................................................39 7.2 Preparing Service VM.............................................................................................40 7.3 FM Shared Library and APIs...................................................................................41 7.4 Fabric Manager Resiliency.....................................................................................44 7.5 Cycle Management ................................................................................................45 7.6 Guest VM Life Cycle Management...........................................................................46 7.7 Error Handling.......................................................................................................47 7.8 Interoperability With MIG........................................................................................48
Chapter 8. vGPU Virtualization Model....................................................................... 49 8.1 Software Stack ......................................................................................................49 8.2 Preparing the vGPU Host .......................................................................................50 8.3 FM Shared Library and APIs...................................................................................51 8.4 Fabric Manager Resiliency.....................................................................................51 8.5 vGPU Partitions .....................................................................................................51 8.6 Guest VM Life Cycle Management...........................................................................52 8.7 Error Handling.......................................................................................................54 8.8 GPU Reset.............................................................................................................54 8.9 Interoperability with MIG........................................................................................54
Chapter 9. Supported High Availability Modes ......................................................... 56 9.1 Definition of Common Terms..................................................................................56 9.2 GPU Access NVLink Failure ...................................................................................57 9.3 Trunk NVLink Failure.............................................................................................58 9.4 NVSwitch Failure...................................................................................................60
Fabric Ma nager fo r NVIDIA NVSwitch Sy stems
DU-09883-001_v0.7 | iv
9.5 GPU Failure...........................................................................................................61 9.6 Manual Degradation ..............................................................................................62 Appendix A. NVLink Topology ...................................................................................... 70 Appendix B. GPU Partitions.......................................................................................... 72 Appendix C. Resiliency.................................................................................................. 74 Appendix D. Error Handling ......................................................................................... 77
Fabric Ma nager fo r NVIDIA NVSwitch Sy stems
DU-09883-001_v0.7 | v
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- azure policies guest configuration technine
- set up on windows 10 a development environment for
- micro focus fortify static code analyzer installation guide
- meshcentral2
- administrator guide
- deepstream sdk 6 0 for nvidia dgpu and jetson
- ubuntu reference cheat sheets
- knime server on azure marketplace
- counteract installation guide forescout
- fabric manager for nvidia nvswitch systems
Related searches
- free contact manager for windows
- best expense manager for android
- business contact manager for outlook 2016
- finance manager for auto dealership
- project manager for dummies
- contact manager for windows 10
- android contact manager for windows
- the new account manager for ford credit
- best contact manager for windows
- best contact manager for iphone
- android manager for windows 10
- business contact manager for outlook