T3x or T3xi Treadmill Troubleshooting
T3x or T3xi Treadmill Troubleshooting | |
|Symptom |Possible Cause |Test Procedure |Repair |
|Noise from under motor cover at |Drive belt misaligned. |- Remove motor cover and verify |- Adjust belt so that it is |
|the front of the unit during | |alignment of drive belt. |positioned at the center of the |
|use. | | |front roller and motor pulley. |
| | | |- Replace drive belt. |
| |Not enough tension on drive belt|- Remove motor cover and check |- Reattach spring to idler. |
| |(usually accompanied by chirping|to see if the spring is attached|- Tighten tension screw on |
| |noise). |to the idler. |idler. If needed, lock nut can |
| | |- Press down with your thumb on |be removed from idler screw. |
| | |tension screw while unit is |- If issue persists, replace |
| | |moving, does sound lessen? |drive belt and/or idler |
| | | |bearings. |
| |Noise coming from motor itself. |- Remove motor cover and check |- Use commentator stone to clean|
| | |motor brushes for contact |commentator. |
| | |(should be copper color). |- If motor without fan, replace |
| | | |motor. |
| | | |- If brushes bad replace motor. |
| |Noise only when belts in motion.|- Remove motor cover and unhook |- If motor pulley makes noise, |
| | |drive belt. Spin both motor |replace motor. |
| | |pulley and idler to check for |- If idler bearings make noise, |
| | |noise. |replace idler bearings. |
| |Noise while elevating. |- Check connection of elevation |- Lubricate elevation rack |
| | |motor to elevation rack at the |screws and worm shaft on |
| | |bottom of unit for lubrication. |elevation motor with heavy |
| | | |grease (lithium works fine). |
| | | |- If metal turning on metal, |
| | | |install Teflon washers. |
|Knocking / banging noise from |Deck shocks are deteriorating. |- Feel consistency of shocks. |- Replace deck shocks. |
|deck / belt area. | |Check if shocks are splitting / | |
| | |tearing. | |
| |Deck bolts are loose. |- Check bolt tightness |- Tighten deck bolts. |
| |Wax build up on rear roller. |- With run belt going slowly, |- Clean rear roller of wax. |
| | |feel rear roller with finger for| |
| | |bumps. | |
|No Belt Movement |No speed sensor reading |- If speed sensor not reading, |- Adjust spacing of speed sensor|
| | |unit should error after 30 |(should be 1 mm from magnets on |
| | |seconds of use. |front roller), bend bracket to |
| | |- Light near ss plugs into lower|get closer. |
| | |board should blink when movement|- Replace ss. |
| | |detected. | |
| | |- Test ss in Product Test in | |
| | |Engineering Mode. SS should | |
| | |read between 4.5 and 5.5 mph in | |
| | |Product Test. | |
| |Bad connection from lower to |- Check connections of console |- If pinched, cut, or bad |
| |upper board. |cable to lower and upper boards.|connections, replace console |
| | | |cable. |
|T3x or T3xi Treadmill Troubleshooting |
|Symptom |Possible Cause |Test Procedure |Repair |
|No belt movement (continued) |Emergency stop engaged |- If program starts, then beeps |- Check to see if e-stop cable |
| | |3 times and goes back to main |is wrapped around handlebar. |
| | |start, e-stop is engaged. |- Replace e-stop |
| |Motor brushes burnt |- Remove motor cover and check |- If motor does not have a fan |
| | |motor brushes for contact |on it, replace motor. |
| | |(should be copper color). |- Use commentator stone to clean|
| | |- Check wiring from motor to |commentator. |
| | |choke for char marks. |- If brushes bad, replace motor.|
|Belt Hesitation or Error 1 |Motor brushes burnt. |- Remove motor cover and check |- If motor does not have a fan |
| | |motor brushes for contact |on it, replace motor. |
| | |(should be copper color). |- Use commentator stone to clean|
| | |- Check wiring from motor to |commentator. |
| | |choke for char marks. |- If brushes bad, replace motor.|
| |Motor without a fan. |- Motor should have a fan |- If motor does not have fan on |
| | |installed on the top of the |it, replace motor. |
| | |motor. | |
| |Running belt loose. |- Check run belt tightness by |- Tighten belt as needed. |
| | |performing stomp test. | |
| |Running deck is worn. |- Crouch down beside run belt, |- Flip or replace run deck. |
| | |and with palm of hand press down| |
| | |hard on the belt. You should be| |
| | |able to move belt easily with | |
| | |weight on palm. | |
| |Insufficient power at club. |- Check club for 20 amp |- If power at club is not |
| | |dedicated circuits with |verifiable, switch outlets with |
| | |non-looped grounds. SEE MATRIX |another treadmill. |
| | |ELECTRICAL REQUIREMENTS. |- Update outlets at club. |
| | |- If power switch is flickering,| |
| | |this is an indication of | |
| | |insufficient power. | |
| |Lower control board bad. |- If upgraded motor installed |- Replace lower control board. |
| | |and belt / deck checked and unit| |
| | |does not pass auto calibration. | |
|No HR |HR Board is Bad |- If HR received, but off, or |- Replace HR Board |
| | |very high. If HR Board bad, you| |
| | |should receive a heart or – | |
| | |signal on the console from HR | |
| | |grips. | |
| |HR Grips are bad |- If no HR received and no |- Replace HR grips. |
| | |signal (heart or --) seen on | |
| | |console. | |
| |HR Wiring is bad |- If no HR received and no |- Replace wiring from HR grips |
| | |signal (heart or --) and the HR |to HR board. |
| | |grip replacement does not work. | |
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- small engine troubleshooting guide
- free troubleshooting car problems
- troubleshooting car problems
- spectrum cable troubleshooting guide
- auto troubleshooting free questions
- car troubleshooting questions
- diesel engine troubleshooting pdf
- troubleshooting car alarm problems
- troubleshooting small honda gas engines
- troubleshooting electronic components pdf
- troubleshooting electronic circuits pdf
- electronics troubleshooting techniques pdf