Technical catalog ABB molded case circuit breakers

Technical catalog

ABB

molded case

circuit breakers

UL 489 and CSA C22.2 Standard

Preliminary - 1SDC210003D0202

Tmax, Isomax, Emax: IndustrialIT enabled!

IndustrialIT is the solution developed by ABB for the all-

certification and is fully entitled to join the ProtectIT suite

round integration of a company¡¯s activities, where each

of products.

product is seen as part of a complete solution. Products

These circuit breakers combine with about 700 products

and technologies are grouped into

in the ranges of distribution boards, thus

functional categories (Suites), each

enabling complete switchboards to be

of which measures,

assembled using all IndustrialIT-certified

controls, optimizes and

components. Moreover, T4 and T5

supports a specific

feature e-plug communication

¡°block¡± of activities, and

interface, which allows Integration

they can ensure

to IndustrialIT systems.

coordinated interaction

Tmax, Isomax and Emax circuit

thanks to the platform

breaker can be integrated with the

created by ABB (AIP: Aspect Integrator Platform).

configurable ABB products in a system: this

In addition to interactivity between certified products,

compatibility has always been a fundamental premise of

every certified product also guarantees the ready

the ABB design process. Mass customization, i.e. the

availability of all the information needed for it to

mass production of components customized to meet a

function - technical characteristics, installation

given buyer¡¯s specific needs is already feasible, as

instructions, use and maintenance instructions,

IndustrialIT certification demonstrates.

environmental certificates and declarations, all updated

Yet again, ABB is ahead of the field in offering a better

to the latest version ¡­ a considerable advantage for the

and better customer service!

user*.

The whole range of Tmax and Isomax molded case and

Emax power circuit breakers has obtained IndustrialIT

* All product technical data and related documentation can be found in

Internet and is accessible to the customer. The standard documentation

is in English, but there are local language versions for each country where

a given product is marketed.

For further information, go to the Products and services/Industrial IT section on our web site:

OVERVIEW

MAIN

CHARACTERISTICS

THE RANGES

ACCESSORIES

CHARACTERISTIC CURVES

AND TECHNICAL

INFORMATION

WIRING DIAGRAMS

OVERALL

DIMENSIONS

C O M P L E T E A N D P E R F E C T LY I N T E G R AT E D

In the range of molded case circuit breakers conforming with the UL 489 and CSA C22.2 Standard, ABB proposes an

entire range which covers current ratings between 15 A and 2500 A and interrupting ratings, at 480 V AC, which can

reach 150 kA.

The ranges available are as follows:

¨C circuit breakers for power distribution (fitted with thermomagnetic or electronic trip units starting from 100 A)

¨C circuit breakers with adjustable magnetic only trip units for motor protection (MCP: Motor Control Protection)

¨C molded case switches for use as isolators or switching devices for lines, busbars or parts of a plant (MCS:

Molded Case Switch)

With the introduction of the new Tmax UL series, a single-pole circuit breaker with interrupting rating of 18 kA

at 277 V AC is available on the American market for the first time.

480 V

All ABB circuit breakers in accordance with the

UL 489 and CSA C22.2 Standard can be

used in installations with wye or delta

distribution systems since use of the circuit

breaker at 480 V AC is guaranteed, even

for the smallest Tmax T1 size.

C O M PA C T D I M E N S I O N S

ABB molded case circuit breakers ensure

high performances in extremely small and

compact dimensions. Standardization of

the depth of the smaller sizes allows more

rational and less deep enclosure to be used

than in the past.

D O U B L E I N S U L AT I O N

Thanks to the double insulation technique,

with all ABB molded case circuit breakers*

the electrical accessories can be mounted

directly on field with the circuit breaker

installed: this allows considerable savings in

time and therefore in costs.

* Except for Isomax S8.

................
................