U-Charge® U1-12RT

U-Charge? U1-12RT

12V Battery Module

U-Charge? RT offers a simple `plug-and-play' replacement for typical lead-acid battery applications.

The Lithium Iron Magnesium Phosphate module offers 40Ah with a peak load capability of up to 80A incorporating built-in automatic protection.

Overview

Providing twice the run-time at approximately half the weight of a comparatively sized lead-acid battery, U-Charge? RT is a perfect choice when lower voltage and intrinsic safety are prerequisites.

Thousands of U-Charge? RT modules are currently in service within numerous industrial products. Excellent float and cycle life results in low operating costs, providing high investment returns for end user applications.

Specifications

U1-12RT

Voltage Nominal Capacity (C/5, 23?C) Weight (approximate) kg Weight (approximate) Ibs

Dimension incl. Terminals LxWxH (mm)

12.8 V 40 Ah 6.5 kg 14.3 Ibs 197 x 131 x 183

Dimension incl. Terminals LxWxH (inches) 7.76 x 5.12 x 7.20

BCI Group Number

Terminals, Female-Threaded

Specific Energy

Energy Density

Max. Cont Current

Standard Discharge @ 23?C

Max. 30 sec. Pulse Cut-off Voltage Run-time @ 10A

Run-time @ 30A

Charge Voltage

Standard Charge

Float Recommended

Charge Time*

DC Internal Resistance (Max)

Equivalent Lithium Content Per Module (g)

Part Number

U1R M6x1.0 79 Wh/kg 110 Wh/l 30 A 80 A 10 V 240 min 80 min 14.6 V 13.8 V 20 A 2.5 hrs 15 m 48.6 1004461

*under recommended conditions

Features

Built-in automatic protection for over-charge, overdischarge and over-temperature conditions No battery management system required Series connection up to four (4) batteries (48 V) Intra-module balancing LED battery status indicator Maintenance-free Flame retardant plastics Thousands of cycles, under normal conditions Can be charged using most standard lead-acid chargers

Optional battery discharge indicator ( U-BDI ) for SOC display and fault indication



Common specifications Operating temperature Storage temperature Operating humidity Water/dust resistance Shock and vibration Certifications

Shipping classification

-10?C to +50?C -40?C to +50?C 5% to 95%, non-condensing

IP56 IEC 62133, DIN VG96 924 FCC Class B, CE, IEC 62133 UL 1642 & UL 2054 RoHS UN 3480, Class 9

CapacCiatpyac(ity%(%Rraattede)d)

U-Charge? Discharge Capacity Performance at 23?C Charged CC 20A to 14.6V, CV @14.6 to 1A DiCshacrghedaUCrC1g2-e01A2dtRo T2140D.6ViAs, CcVthoa@r1g41.e60tCo.5a1ApV;aD;cisiCtcyhayPrgceedrlfe2o0drAmto4a1n20c.5eMV;aCtoy2cn3let?dhC42sMonths

100 90 80 70 60 50 40 30 20 10 0 0

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

4,500

5,000

CycleCsycles

U-Charge? Discharge Voltage Profiles at C/2 Discharge Rate Various Ambient Temperatures

U1-12XP Discharge Voltage Profiles at C/2 Discharge Rate and Various Ambient Temperatures

13.5

13

12.5

12

11.5

11

10.5

10 0

50?C 40?C 30?C 20?C 10?C 0?C -10?C

10

20

30

40

50

60

70

80

90

100

CapaCacpaitcyity %(%)

VVoltolatgea (gV)e

Voltage (V) Voltage (V)

V Vololttaagge (eV)V

Accessories

U-BDI ? a wired, remote U-Charge? Battery Discharge Indicator displaying a 10 segment State-of-Charge (SOC).

LED indication bar and battery status indicators. The U-BDI also monitors and controls batteryto-battery balance within a battery string.

U-Charge? Voltage Profiles at Various Rates 23?C Ambient Temperature

UCharge Voltage Profiles at Various Rates and 23?C Ambient Temperature

14

C/8

13.5

C/5

C/3

C/2

13

1C

2C

12.5

12

11.5

11

10.5

10 0

20

40

60

80

100

CaCpaapacciityty(%%)

Typical U-Charge? C/2 Charging Voltage and SOC Profiles 23?C Ambient Temperature

Typical UCharge C/2 Charging Voltage and SOC Profiles at 23?C Ambient Temperature

15

100

90

14.5 80

70 14

60

13.5

50

40

13 30

20 12.5

10

12 0

0

30

60

90

120

150

CharginTgimeT(mimin.)e (min)

State of Charge (%)

State Of Charge (SOC)

Corporate Headquarters

North America Sales

12303 Technology Blvd. Suite 950 Austin, Texas 78727 USA

Tel Fax Email

(888) VALENCE or +1 (512) 527-2900 +1 (512) 527-2910 sales@

EMEA

Sales

Unit 63 Mallusk Enterprise Park Mallusk Co.Antrim Northern Ireland BT36 4GN

Tel Fax Email

+44(0) 28 9084 5400 +44(0) 28 9083 8912 sales@

Performance may vary depending on, but not limited to cell usage and application. If cell is used outside specifications, performance will diminish. All specifications are subject to change without notice. All information provided herein is believed, but not guaranteed, to be current and accurate. Copyright ? 2005-2013 Valence Technology, Inc.

Tell us about your application at:

Jan 2013 U1-12RT Datasheet

................
................