Cisco Connected Grid Ethernet Switch Module Interface Card ...

Cisco Connected Grid Ethernet Switch Module Interface Card Getting Started Guide

First Published: May 2012 Last Updated: January 2014 Part Number: OL-23421-02

Cisco Systems, Inc.

Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at go/offices.

Text Part Number: OL-23421-02

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB's public domain version of the UNIX operating system. All rights reserved. Copyright ? 1981, Regents of the University of California.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED "AS IS" WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

CCDE, CCENT, Cisco Eos, Cisco HealthPresence, the Cisco logo, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, Cisco WebEx, DCE, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, iQuick Study, IronPort, the IronPort logo, LightStream, Linksys, MediaTone, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet, Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

No combinations are authorized or intended under this document.

Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.

? 2012?2014 Cisco Systems, Inc. All rights reserved.

CONTENTS

1 C H A P T E R

2 C H A P T E R 3 C H A P T E R

OL-23421-02

Preface iii Purpose iii Document Conventions iii Related Publications iv Obtaining Documentation and Submitting a Service Request iv

Product Overview 1-1 Switch Models 1-1 Ports 1-2 Port Locations 1-2 Port Labeling 1-3 10/100BASE-T Ports 1-4 PoE and PoE+ Ports 1-4 10/100 Mb/s SFP Module Slots 1-5 100/1000 Mb/s SFP Module Slots 1-5 Dual-Purpose Gigabit Ethernet Ports 1-5 Supported SFPs 1-6 LEDs 1-7 Router Compact Flash Memory Cards 1-9

Installation 2-1 Pre-Installation 2-1 Installation Warning Statements 2-1 Installation 2-2 Connecting to the Network 2-5 Connecting the Copper Switch Module 2-5 Connecting the Fiber Switch Module 2-6 Removing the Switch Module 2-7

Express Setup 3-1 System Requirements 3-1 Express Setup 3-1

Cisco Connected Grid Ethernet Switch Module Interface Card Getting Started Guide

1

Contents

4 C H A P T E R A A P P E N D I X

Troubleshooting Express Setup 3-5 Resetting the Switch Module 3-5

Managing the Switch Module 4-1 Using the Device Manager 4-1 Cisco Configuration Professional 4-1 Other Management Options 4-2 Accessing the Switch Module 4-2 Disconnecting from the Switch Module 4-3 Connecting Devices to the Switch Module 4-4 10/100BASE-T Ports 4-4 SFP Module Slots 4-5 Dual-Purpose Port with RJ-45 and SFP Connectors 4-7 Verifying Port Connectivity 4-9

Cable and Connectors A-1 Connector Specifications A-1 10/100BASE-T Ports A-1 SFP Module Connectors A-1 Dual-Purpose Ports A-2 Cables and Adapters A-2 SFP Module Cables A-2 Cable Pinouts A-4

Cisco Connected Grid Ethernet Switch Module Interface Card Getting Started Guide

2

OL-23421-02

Preface

Purpose

This guide describes the hardware features of the Cisco Connected Grid Ethernet Switch Module Interface Card (switch module). It describes how to install the switch module in the Cisco 2010 Connected Grid Router, and how to configure it. This guide also describes how to: ? Access the switch module from the host router ? Connect devices to the switch module ports ? Manage the switch module ? Perform Express Setup troubleshooting

Document Conventions

Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual.

Caution Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.