MRI CryoProbe Site Planning User Manual
MRI CryoProbe
Bruker User Manual Site Planning
Version 001
MRI
Innovation with Integrity
Copyright ? by Bruker Corporation
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means without the prior consent of the publisher. Product names used are trademarks or registered trademarks of their respective holders.
This manual was written by
R. Mudra, M. Sacher, S.Zwick & D. Marek
? July 13, 2012: Bruker Corporation
F?llanden, Switzerland
P/N: Z31824 DWG-Nr.: Z4D10381
For further technical assistance on the MRI CryoProbe unit, please do not hesitate to contact your nearest BRUKER dealer or contact us directly at:
BRUKER Corporation am Silberstreifen D-76287 Rheinstetten Germany Phone:+ 49 721 5161 0 FAX:+ 49 721 5171 01 E-mail:service@bruker.de Internet:
Contents
Contents
1 About ..............................................................................................................5
1.1
This Manual............................................................................................................ 5
1.2
Policy Statement .................................................................................................... 5
1.3
Symbols and Conventions...................................................................................... 5
2 Introduction....................................................................................................7
2.1
How to Use this Ordering Information .................................................................... 7
3 System overview/ Requirements .................................................................9
3.1
General Information................................................................................................ 9
3.1.1
The CryoProbe Prodigy (CPP) ............................................................................. 10
3.1.2
The CryoPlatform Prodigy ................................................................................... 10
3.1.3
The Prodigy Unit .................................................................................................. 10
3.1.4
The LN2 vessel, vessel adapter & transferline..................................................... 10
3.2
Transport dewar ................................................................................................... 11
3.3
AVANCE compatibility.......................................................................................... 11
3.4
General requirements........................................................................................... 12
3.5
Safety in the Lab .................................................................................................. 16
4 Site Planning Questionnaire.......................................................................19
4.1
Site Planning Checklist......................................................................................... 19
4.2
Special Site Planning Checklist for Existing Magnets .......................................... 25
5 Ordering Information...................................................................................29
5.1
Ordering Procedure.............................................................................................. 29
5.2
General System Requirements ............................................................................ 29
5.3
General Ordering Structure of the CryoProbe Prodigy System............................ 30
5.4
CryoProbe Prodigy (CPP) and Accessories......................................................... 31
5.5
Prodigy CryoProbe Mounting Hardware............................................................... 31
5.6
Shimsystem.......................................................................................................... 32
5.6.1
Variable Temperature (VT) Gas -> CET: OI V008 abwarten .............................. 32
5.7
Sample Protection ................................................................................................ 33
5.8
Required Magnet Modifications for Prodigy CryoProbe Installations ................... 34
5.9
Separator & Air dryer............................................................................................ 34
5.10
Optional: Cold Dismount Kit ................................................................................. 34
5.11
Order Checklist..................................................................................................... 35
6 Contact .........................................................................................................37
Z31824 / Rev.: 01
3
Contents
4
Z31824 / Rev.: 01
1 About
1.1 This Manual
This manual is intended to be a reference guide for operators and service technicians. It provides detailed information about the user level maintenance and service and overall use of the Bruker device. The figures shown in this manual are designed to be general and informative and may not represent the specific Bruker model, component or software/firmware version you are working with. Options and accessories may or may not be illustrated in each figure. Carefully read all relevant chapters before working on the device! This manual describes parts and procedures relevant to the device version it is delivered with. For older hardware, please refer to the manual supplied at the time.
1.2 Policy Statement
It is the policy of Bruker to improve products as new techniques and components become available. Bruker reserves the right to change specifications at any time. Every effort has been made to avoid errors in text and figure presentation in this publication. In order to produce useful and appropriate documentation, we welcome your comments on this publication. Support engineers are advised to regularly check with Bruker for updated information. Bruker is committed to providing customers with inventive, high quality products and services that are environmentally sound.
1.3 Symbols and Conventions
Safety instructions in this manual are marked with symbols. The safety instructions are introduced using indicative words which express the extent of the hazard. In order to avoid accidents, personal injury or damage to property, always observe safety instructions and proceed with care.
DANGER
This combination of symbol and signal word indicates an immediately hazardous situation which could result in death or serious injury unless avoided.
Z31824 / Rev.:001
5
About
WARNING
This combination of symbol and signal word indicates a potentially hazardous situation which could result in death or serious injury unless avoided.
CAUTION
This combination of symbol and signal word indicates a possibly hazardous situation which could result in minor or slight injury unless avoided.
NOTICE
This combination of symbol and signal word indicates a possibly hazardous situation which could result in damage to property or the environment unless avoided.
i This symbol highlights useful tips and recommendations as well as information designed to ensure efficient and smooth operation.
6
Z31824 / Rev.:001
3 Introduction
BRUKER MRI CryoProbesTM offer a dramatic increase in the signal-to-noise ratio (SNR) by reducing the operating temperature of the NMR coil assembly and the preamplifier. An automatic closed-cycle cooling system controls all functions and guarantees excellent stability during short and long-term experiments. As a result, the system is easy to handle. MRI CryoProbes open new fields for MRI/MRS applications where SNR, the spatial resolution or measurement time are critical.
3.1 How to use this Site Planning Guide
This MRI CryoProbe Site Planning Guide provides information about a MRI CryoProbe system which can be used with an already existing or a new MRI system. With the information of this document the Bruker BioSpin service representative can perform a Site Planning with the customer. After the Site Planning all information should be available to prepare a successful installation of the MRI CryoProbe system. First an overview about the main parts of the MRI CryoProbe system with technical details is given in Chapter 3. The specifications of the MRI CryoProbe system is given within Chapter 4. In Chapter 5 is the Site Planning procedure in 7 steps described which allows to check if an installation is possible. With the Questionnaire of Chapter 6 all details necessary for a successful installation are checked at the customer site. This information has to be send back to Bruker to allow for the final check. Finally, the checklist is given, where the customer has to declare, that he provided the necessary infrastructure for an MRI CryoProbe installation.
Z31824 / Rev.: 01
7
Introduction
8
Z31824 / Rev.: 01
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- excel user manual pdf
- excel 2016 user manual pdf
- excel user manual free download
- microsoft project user manual pdf
- sap user manual pdf
- microsoft flight simulator 2020 user manual pdf
- unity user manual pdf
- apple iphone 11 user manual pdf
- onenote user manual pdf
- user manual for iphone 11 pro
- kindle user manual pdf
- android user manual free download