VSR Data Sheet - Manning Environmental



|Model VSR Stationary Vacuum Sampler (Refrigerated) | |

| Low Cost of Ownership | |

|Over their useful life, vacuum samplers are the least expensive suction lift samplers to| |

|own. With few moving parts, critical components rated for thousands of operations, and | |

|no regularly scheduled replacement of consumable parts (such as peristaltic pump | |

|tubing), labor and spare parts costs are minimized. It is possible to save hundreds, if| |

|not thousands, of dollars over the useful life of a Model VSR sampler. | |

| Versatile Controller | Durable Construction |

|The sampler’s microprocessor-based controller is housed in an |Manning samplers over twenty years old are still in regular |

|enclosure rated for environmental protection by the National |service. No other sampler company can claim a longevity record |

|Electrical Manufacturers Association as NEMA 4X/NEMA 6. The controller|like that! The VSR is no exception. Its Acrylonitrile Butadiene |

|offers advanced functionality and features, such as data logging, |Styrene (ABS) enclosure protects the electromechanical parts and |

|review of settings and operating status, with a variety of flow and |the stainless steel hardware can withstand corrosive environments. |

|time modes. With its step-by-step menu format, dedicated-button |These features, along with watertight connectors, ensure that no |

|keypad, and large backlit LCD, the controller is simple to set up, |other sampler will last as long as a Manning VSR sampler. |

|even in the dark! Easy to understand prompts and short cut | |

|keys save manpower and time by enabling the operator to quickly change or review programming | Standard Refrigerator |

|and settings, avoiding frustrating navigation through long, complicated menu structures. |The optional 110 or 220 VAC refrigerator is durable, corrosion |

| |resistant, and is offered in a white enamel-coated or stainless |

| |steel finish. Capable of maintaining samples at the EPA |

| |recommended 0(4(C, even in high |

| | |

|Comprehensive, Flexible Programming | |

|The exceptional sampling software is designed to be highly flexible and easy to use. The |ambient temperatures, this industrial-grade refrigerator is built |

|menu-driven system provides many programming features. (See partial listing in Specifications|to handle the toughest environments. Features, such as a |

|reverse side) |corrosion-resistant frame and exterior, |

| Accurate, Repeatable Sample Volumes |refrigerant lines wrapped with asphalt cork tape to resist damaging |

| |environments, with corrosion resistant finish, and a heavy-duty |

| |compressor ensure reliable operation under the harshest conditions. |

|Precise accuracy and repeatability of sample volumes for the SR sampler is within 0.5% of | |

|pre-set volume (versus the ±5% volume typical of a peristaltic sampler). The collected | |

|sample will be exact, ensuring the validity of your sampling data. | |

| Manning VSR Refrigerated Sampler |

|Size (HxWxD): |W 23.875 in. (60.65 cm) x H 50.75 in. (128.9 cm) x |

| |D 24 in. (60.96 cm) |

| |Optional NEMA 3R Sampler Enclosure: W 32 in. (81.3 |

| |cm) x H 74 in. (187.9 cm) x D 30 in. (76.2 cm) |

|Weight: (dry) |Sampler: 17.5 lbs (7.94 kg). |

| |Standard Refrigerator (6.1 cu. ft.): 110 lbs (49.9|

| |kg) |

| |Multi-bottle assembly: 50.5 lbs (22.91 kg) |

| |Single bottles: 15.5 lbs. (7.03 kg) Weights vary |

| |with size and material. All weights are without |

| |packaging or pallets. |

|Environmental Protection |NEMA 4X/NEMA 6 ABS housing around electromechanical|

| |components with all stainless steel hardware |

|Temperature Limits | Standard unit: 32(122(F (0(50(C); unit with |

| |optional NEMA 3R with heater and fan: -40(122(F |

| |(-40(50(C) |

| Sample Pump |Diaphragm vacuum compressor pump, 12 VDC |

|Maximum Lift |28 ft (8.53 m)** |

|Intake Hose |Size: 3/8-inch ID (5/8 inch OD) hose or 5/8 inch ID|

| |(7/8 inch OD) |

| |Hose Type: PVC or Teflon in 10 ft (3 m), 25 ft (7.6|

| |m), 50 ft (15.2 m), or 100 ft (30.4 m) lengths |

|Transport Velocity |With 3/8 inch ID hose: 5.13 ft/sec @ 5 ft of lift |

| |(1.56 m/sec @ 1.5 m of lift) |

|Sample Volume |Large chamber holds 500 ml per cycle; maximum of |

| |2000 ml using multiple chamber fills (max. 4) |

|Accuracy |(0.5% of set volume |

|Repeatability |(0.5% of the average largest and smallest sample |

| |volume in a sample set |

|Membrane Keypad |Hermetically sealed 24-key, multiple function |

| |keypad with 2-line by 20-character alphanumeric |

| |backlit LCD |

|Refrigeration |

|Standard units are capable of maintaining the sample bottle compartment at |

|32(39(F (0(4(C) for ambient temperatures to 120(F (49(C) and are provided |

|with either a white enamel coating or stainless steel exterior. 4.1 cu. ft. |

|units are capable of maintaining the sample bottle compartment at 32(39(F |

|(0(4(C) within an ambient temperature range of 40(110(F (4.4(43.33(C)* and |

|are provided with a white enamel coating only. |

|Sampler Programming |

|Programming features include but are not limited to: |

|Data logging (512-event capacity) |Bottle grouping |

|Flow proportional pacing (contact |Program delay (time or flow) |

|closure) |Sampling based on external device |

|Flow pacing with time override |input |

|capability |Hydrologic level event mode (storm |

|Flow pacing with delay sampling |water sampling) |

|feature |Real-time clock (time and date) |

|Flow pacing with maintained event |Password protection |

|sampling |Manual test cycle feature |

|Totalized flow pacing (analog input) |Activity review log (current and past)|

|Uniform and non-uniform time intervals|Intake fault alert |

|Multiple bottles per sample |Intake line purge |

|Multiple samples per bottle |Automatic shut-off |

|Multiple bottle compositing |Power fail/auto restart |

| | |

| | |

|Power |

|Internal Clock |Indicates real time within 1 minute per month |

| |accuracy |

|Internal Battery Backup |5-year internal lithium battery to maintain program|

| |logic, RAM memory, real-time clock |

|Power Requirement |110 VAC (60 Hz) or, 220 VAC (50 Hz), both with |

| |battery backups available. |

|Refrigerator inside body: |Linear low-density poly-ethylene (LLDPE) |

|Alarm Contacts (optional) |Three SPST contacts rated 5 A 110/220 VAC |

|Input/Output (optional) |Contact closure with or without 4(20-mA input |

| |and/or RS-232 output in various combinations |

|Warranty |

|One year from date of shipment. |

|Ordering Information |

|Model VSR Sampler Spare Parts/Accessories |

|( Replacement Pinch/Discharge Tubing: |( Cables: |

|3/8-inch tubing P/N MS566925B* |3 ft. (1 m) long, 4-pin plug |

|5/8-inch tubing P/N MS566919B* *Please|contact/analog input cable P/N MS818016 |

|specify required length in feet. |10 ft. (3 m) long, 4-pin plug |

|( Replacement Intake Hose |contact/analog input cable P/N MS818018 |

|5/8-inch bulk clear intake hose P/N |Serial Output (RS-232 6-inch Patch Cable)|

|MS566918** |P/N MS810059 |

|5/8-inch bulk nylon-reinforced intake |( Replacement Bottles: |

|hose P/N MS566901** |One 2.5-gallon poly-ethylene bottle w/cap|

|3/8-inch bulk clear intake hose P/N |P/N MS687547 |

|MS566917** |One 4-gallon poly-ethylene bottle w/cap |

|3/8-inch bulk Teflon(-lined intake |P/N MS687551 |

|hose P/N MS566931** |One 5-gallon poly-ethylene bottle w/cap |

|**Please specify required length in |P/N MS687535 |

|feet. |One 2.5-gallon glass bottle w/Teflon( lid|

|( Hose Couplings |liner P/N MS889715 |

|5/8-inch straight female hose coupling|Set of 24 1000-ml poly-ethylene bottles |

|P/N MS552031 |w/caps P/N MS889117 |

|3/8-inch female quick disconnect |Set of 24 500-ml poly-ethylene bottles |

|fitting P/N MS552104 |w/caps P/N MS889041 |

|3/8-inch male quick disconnect fitting|5-gal container with splashguard & |

|P/N MS552105 |transport lid P/N MS889721 |

|( Pressure Switch |• Strainers: |

|P/N MS638540 |3/8-inch PVC strainer P/N MS889147 |

|( Conversion Kits |3/8-inch Stainless Steel strainer P/N |

|Multi-bottle to single bottle |MS579591 |

|(3/8-inch) P/N MS889774 |5/8-inch PVC strainer P/N MS889148 |

|Multi-bottle to single bottle |5/8-inch Stainless Steel strainer P/N |

|(5/8-inch) P/N MS889775 |MS579584 |

| |( Manual |

| |P/N MAN-VSR |

In the interest of improving and updating its equipment, Manning reserves the right to alter specifications to equipment at any time.

Ordering Information

|MODEL NUMBER |

|VSR3 3/8-inch ID vacuum pump stationary sampler system (requires 3/8-inch sampling hose) |

|VSR5 5/8-inch ID vacuum pump stationary sampler system (requires 5/8-inch sampling hose) |

| |POWER REQUIREMENT |

| |A 110 VAC C Battery backup -- 110 VAC (for sampler only ( not refrigerator) |

| |B 220 VAC D Battery backup -- 220 VAC (for sampler only ( not refrigerator) |

| | |REFRIGERATOR |

| | |1 None 4 Stainless steel -- 110 VAC, 60 Hz |

| | |2 Standard -- 110 VAC, 60 Hz 5 Stainless steel -- 220 VAC, 50 Hz |

| | |3 Standard -- 220 VAC, 50 Hz 8 4.1 cu. ft. – 110 VAC, 60 Hz* |

| | | |

| | |* Recommended for single bottle applications, protected from the elements, indoors, or in a shelter only. Hood option not |

| | |available on this refrigerator. See 4.1 cu. ft. Refrigerator Data Sheet. |

| | | |INPUT/OUTPUT OPTION (3’ input cable included with all units and patch cable for RS-232 output when applicable) |

| | | |A Contact closure input C Contact closure plus Serial output (RS-232) |

| | | |B Contact closure plus analog (4–20-mA) input D Contact closure and Analog (4-20mA) Input |

| | | |plus RS-232 output |

| | | | |BOTTLE CONFIGURATION |

| | | | |A Single bottle (for composite sampling) D Multi-bottle for Discrete Sampling (2 or 4 Bottle |

| | | | |C Multi-bottle (for discrete sampling) Distribution) |

| | | | | |BOTTLE TYPE |

| | | | | |1 None 6 1000-ml poly-ethylene |

| | | | | |2 2.5-gallon poly-ethylene 7 500-ml poly-ethylene |

| | | | | |3 5-gallon poly-ethylene 10 4 ea 2.5 gallon poly-ethylene |

| | | | | |4 4-gallon poly-ethylene 11 2 ea 2.5 gallon poly-ethylene |

| | | | | |2.5-gallon glass w/Teflon( lid liner |

| | | | | |9 5-gal poly-ethylene container with |

| | | | | |snap on lids |

| | | | | | |SAMPLING HOSE TYPE |

| | | | | | |A None |

| | | | | | |B 3/8 inch ID PVC hose -- 10 ft H 5/8-inch ID PVC hose -- 50 ft |

| | | | | | |C 3/8 inch ID PVC hose -- 25 ft J 5/8-inch ID PVC hose -- 100 ft |

| | | | | | |D 3/8 inch ID PVC hose -- 50 ft K Teflon( hose -- 10 ft (3/8 inch ID only) |

| | | | | | |E 3/8 inch ID PVC hose -- 100 ft L Teflon( hose -- 25 ft (3/8 inch ID only) |

| | | | | | |F 5/8 inch ID PVC hose -- 10 ft M Teflon( hose -- 50 ft (3/8 inch ID only) |

| | | | | | |G 5/8 inch ID PVC hose -- 25 ft N Teflon( hose -- 100 ft (3/8 inch ID only) |

| |

Engineering Specification

|The sampler is suitable for automatic collection |Refrigeration: The Standard Refrigerator is |Manual sampling, independent of a programmed |

|and preservation of composite or discrete |composed of carbon steel (with iron phosphate |sequence, is initiated by a keystroke. The |

|non-toxic liquid samples. |pretreatment, covered by white baked acrylic |sampler logs manual collections and is |

|The enclosure is a thick walled ABS with NEMA |enamel) or stainless steel. The refrigerator |selectable to allow taking test samples: |

|4X/NEMA 6 ratings. |condenser is made of carbon steel with a baked |Only when the sampler is not running a program,|

|Minimum internal diameter (ID) of all wetted |enamel finish. Copper refrigerant lines are coated|During a program, but the test sample is not |

|parts is 3/8 inch or 5/8 inch, as ordered. |with asphalt cork tape for protection from hydrogen|counted as a sample, or |

|Non-toxic samples shall be collected using a |sulfide gas attack. The refrigerator thermostat is|During a program and the test sample is counted|

|clear PVC measuring chamber adjustable 20(500-ml |capable of maintaining a temperature of 0(4°C. The|as a sample. |

|sample volume and (0.5% repeatability of preset |evaporator plates have a baked-on, powder coat |In the Time Mode, the interval between samples |

|value. All wetted parts are stainless steel, |paint finish for protection. The fan motor is unit|is adjustable (1 - 5999 min. in 1-minute |

|PVC, or silicone. |bearing. The 440 BTU compressor has a high |increments). In the Flow Mode, the sampler |

|The sampler incorporates vacuum compressor |efficiency fan and condenser arrangement permitting|accepts and totalizes contact closures (1(9999)|

|technology. The sampling mechanism consists of a|reliable operation in high ambient temperatures. |or a 4–20-mA DC analog signal input for |

|heavy-duty vacuum compressor with an aluminum |Foam insulation forms a CFC-free poly-ethylene with|sampling at a user set point. |

|body coated with corrosion-resistant paint. The |an interior of food-grade plastic. The capacity is|The sampler uses a hydrologic event algorithm |

|sample does not pass through a pump. Samplers |6.1 cu. ft. The 4.1 cu. ft. Refrigerator is for |to enable sample programming based on a |

|using technologies requiring regularly scheduled |single bottle use, only when protected from the |combination of parameters, including water |

|parts replacement will not be acceptable. A |elements, or for indoor or sheltered applications. |level, differential (rising and falling) water |

|500-ml precision measuring chamber with ( 0.5% |The exterior is white enamel coated steel. The |levels, and time defaults as established for |

|repeatability of preset volume is used. Multiple|cabinet and door insulation is polyurethane with an|hydrologic events by the U.S. Geological |

|draws (up to 4) are possible for a total sample |interior plastic liner for cabinet and door of |Survey. |

|volume of 2000 ml. There is no need to |food-grade quality. The refrigerator thermostat is|Operating status is reviewed with minimal |

|compensate for changes in draw height or intake |capable of maintaining the EPA-recommended |effort and includes: |

|line length. |temperature of 0(4°C provided the ambient |Program status, |

|The sampler enables field conversion from |temperature is within the specifications listed in |Time and date program started, |

|multiple to single bottle sampling to collect |the 4.1 cu. ft. Refrigerator data sheet. The |Minutes or flow signals remaining to the next |

|non-toxic liquids by using a parts kit which does|capacity is |sample, |

|not require special tools. |4.1 cu. ft. Please see the 4.1 cu. ft. |Bottle number, |

|The sampler collects composite and/or discrete |Refrigerator Data Sheet for more specifications. |Number of samples collected, |

|samples. For composite sampling, an overflow |No unique symbols or codes for programming, or to |Number of samples remaining, |

|protection mechanism shall automatically |indicate operating conditions, are used. The |Volume collected, and |

|terminate any further sampling. Discrete |software is menu driven; prompting input of |Volume remaining. |

|sampling can be multiple bottles of the same |requested information by using the keypad. The |All program settings are reviewed followed by a|

|sample or multiple samples in multiple bottles. |display indicates each programming step. After |review of the completed program. |

|Bottle-full condition is detected using a |entering data, the system automatically advances to|The entire refrigerated sampler is enclosed in |

|stainless steel sensor located in the bottleneck.|the next programming step. |an optional weather-resistant, NEMA 3R outdoor |

|It is easily removable for cleaning or |A password feature is used to restrict access to |enclosure made of fiberglass-reinforced |

|replacement without using special tools. |authorized persons only. |polyester and insulated with 0.75 in. (19.05 |

|The sampler is capable of collecting 20(2000-ml |A sampling program can be delayed by entering the |mm) thick polyurethane. It is equipped with a |

|samples through a 3/8-inch ID sample line at a |number of hours and minutes for the sampler to |full-sized gasketed door with lockable latch, |

|minimum transport velocity of 2.5 ft/sec at 20 ft|count down (up to 99 hrs, 59 min), or the number of|duplex electrical outlet, air vents, and access|

|of lift using a 25-foot sampling hose, and 5.13 |contact closures to occur. The delay is |holes for the sampling hose. It also includes |

|ft/sec at 5 ft of lift using a 15-foot hose. |independent of the sampling interval. |any or all of the following: an optional heater|

|An optional weighted sampling strainer of PVC or |The sampler purges the sampler hose immediately |with thermostat suitable for sampler operation |

|stainless steel is used. |prior to and following each sample. Purge duration|to -40ºF (-40ºC) outside temperature, an |

|A hermetically sealed 24-button keypad and a |is selectable from 3(99 seconds. |optional light and/or optional fan. See the |

|2-line by 20-character alphanumeric backlit LCD |If a sample is not obtained on the first attempt, |NEMA 3R data sheet for more information. |

|is linked to a programmable CPU. |the sampler immediately retries to collect the |The sampler is a Manning Model VSR series. |

| |sample. If a sample still cannot be collected, the| |

| |sampler will omit that sample and continue the | |

| |sampling sequence. | |

Data Sheet: VSR

10/01/2012

V:11.0

Headquarters and Sales:

|Manning Environmental, Inc. |Phone: (800) 863-9337 |

|101 Bar T Dr. |Fax: (254) 793-9965 |

|Florence, Texas 76527 |Email: sales@manning- |

| |Web: |

In the interest of improving and updating its equipment, Manning reserves the right to alter specifications to equipment at any time.

-----------------------

Environmental Inc

For single

bottle only

For multi- bottle only

Manning Environmental, Inc.

101 Bar T Dr.

Florence, Texas 76527 USA

Office: (800) 863-9337

Fax: (254) 793-9965

E-Mail: sales@manning-

Web:

Only for 24 bottle sampler

[pic]

................
................

In order to avoid copyright disputes, this page is only a partial summary.