Surge-Trap® POP + SPD Type 2 – For Contactor
[Pages:2]Surge-Trap? POP + SPD Type 2 ? For Contactor
Surge-Trap? POP + SPD Type 2 ? For Contactor
POWER FREQUENCY OVERVOLTAGE PROTECTION FOR POWER LINES
COMBINED SPD + POP
POP CT is the series of combined power frequency overvoltage protection (POP) and surge protection device for discharging surge current in the first step of protection according to EN/IEC 61643-11.
Intended for actuation on the contactor of an installation (not included). Suitable for the first stage of protection in commercial or other applications not exposed to direct strikes and with no external lightning protection system. These devices are suitable for installation in lighting panels.
TECHNICAL DATA OVERVIEW
Class
Type 2 / Class II
Un
230/400V
Uc
400 V
Imax
40 kA
In (8/20)
15 kA
Body Material
PC+FG; V-0
Number of Poles
4
Format
Monobloc
Temperature range -5 ... 40 ? C
Icc
25 kA
IP Code
20
Back-up fuse
80 A gG
Maximum break time 0,2 s - (400V) / 15 s - (275V)
Stranded wire Section 6 ... 25 mm?
Rigid wire Section
6 ... 35 mm?
FEATURES & BENEFITS
? Maximum discharge current (8/20s): 40kA per phase
? Nominal discharge current (8/20s): 15kA per phase
? Un(L+N/L-L): 230/400V ? DIN-rail mountable, monobloc for-
mat ? Visual and remote end of life indica-
tors ? Back-up fuse: 80 A gG ? Maximum break time (400V): 0,2 s ? Maximum break time (275V): 15 s ? Back-up fuse: 80 A gG
APPLICATIONS
? Industry and automation ? LED outdoor lighting
STANDARDS
? IEC 61643-11 ? EN 61643-11
MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.
Power Frequency Overvoltage Protection for Power Lines / DS-SPDPT240C-03-0519_EN
EP.
1
Surge-Trap? POP + SPD Type 2 ? For Contactor
PRODUCT RANGE
4 Poles
Catalog number
Item number
Un
POP-40K230V-CT-4P 83060100 230/400 VAC POP-40K230V-CT-4PM 83060101 230/400 VAC
ELECTRICAL DIAGRAMS
(3Ph+N)-4P
Uc
400 V 400 V
Imax (8/20)
40 kA 40 kA
In (8/20)
15 kA 15 kA
Up at In
1.8 kV 1.8 kV
Remote
No Yes
DIMENSIONS
4 Poles
MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet.
Power Frequency Overvoltage Protection for Power Lines / DS-SPDPT240C-03-0519_EN
EP.
2
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- ep2050ee high performance filter and spd for your home
- surge protection of power supply spd type 2 for ac power
- org
- download power rangers spd full episodes in hindigolkes
- download power rangers spd full episodes in hindi
- aaron j nelson
- what is the surge trap spd
- full episodes of power rangers spd in hindi
- surge protection of power supply spd type 3 for ac power
- power rangers spd full episodes free download in tamil
Related searches
- crps type 2 versus type 1
- type 1 type 2 difference
- type 1 diabetes vs type 2 diabetes
- recommended daily carbs for type 2 diabetes
- type 1 vs type 2 myocardial infarction
- type 1 and type 2 diabetes
- type 1 vs type 2 diabetes
- type 1 vs type 2 diabetes chart
- type 1 vs type 2 nstemi
- bedtime snacks for type 2 diabetes
- compare type 1 and type 2 diabetes
- differentiate type 1 and type 2 diabetes