15 SERIES Single one Mini-Split Inverter System MMHW15A1NA ...

M4MHW1509A-SUB-1B

TAG: _________________________________

SUBMITTAL

Specifications

15 SERIES

MODEL - Heat Pump Only

Single Zone Mini-Split

Inverter System

M4MHW1509A1N0A

M4THS1509A11NA

RATED Volts/PH

Frequency (Hz)

Rated Cooling / Heating Capacity (Btu/h):

Minimum Cooling Capacity (@95F) (Btu/h):

Maximum Cooling Capacity (@95F) (Btu/h):

Minimum Heating Capacity (@47F) (Btu/h):

Maximum Heating Capacity (@47F) (Btu/h):

Maximum Heating Capacity (@17F) (Btu/h):

Total Capacity (W) (High/Standard/Low):

Rated Power Input (W)

Nominal Input Current (A)

SEER / HSPF

Air Flow Volume (CFM) (H/M/L)

Dehumidifying Volume (pt./h)

EER/COP (@95F)

M4HW1509A1 / M4THS1509A1

Cooling

Heating

208 / 230 / 1

60Hz

9000

9500

3100

9600

3100

12000

5600

2800 / 2600 / 900

3500 / 2700 / 900

900

800

4.0

3.6

15.00

9.0

310 / 280 / 240 / 170

1.69

10.0

11.9

Indoor Unit

M4MHW1509A1N0

Fan Motor Speed (r/min) (SH/H/M/L)

1350 / 1200 / 1050 / 750 1350 / 1200 / 1050 / 850

Fan Motor RLA(A)

0.20

Evaporator

Aluminum Fin-Copper Tube

Pipe Diameter (inch)

1/5

Row Fin Gap (inch)

2 - 1/18

Coil length (L) x depth (D) x coil width (W) (inch)

23 7/8 10 1/2

Output of Swing Motor (W)

1.5

Fuse (A)

3.15

Sound Power Level dB (A)(SH/H/M/L)

53 / 49 / 45 / 39

Sound PRESSURE Level dB (A)(SH/H/M/L) 1

43 / 38 / 34 / 28

Uncrated Dimension (W/H/D) (inch)

31 1/9 x 10 5/6 x 7 7/8

Crated Dimension of Package (L/W/H) (inch)

34 x 10 2/3 x 14 4/9

Net Weight /Gross Weight (lbs)

19.8 / 24.2

Outdoor Unit

Compressor Type

Compressor Oil

L.R.A. (A)

Compressor RLA(A)

Compressor Power Input(W)

Throttling Method

Working Temp Range (F)

Condenser

Pipe Diameter (inch)

Row Fin Gap (inch)

Coil length (l) x depth (D) x coil width (W) (inch)

Fan Motor Speed (rpm)

Output of Fan Motor (W)

Fan Motor RLA (A)

Air Flow Volume of Outdoor Unit (CFM)

Fan Diameter (inch)

Defrosting Method

Sound Power Level dB (A)

Sound PRESSURE Level dB (A) 1

Uncrated Dimension (W/H/D) (inch)

Crated Dimension of Package (W/L/H) (inch)

Net Weight /Gross Weight (lbs)

Refrigerant Charge (oz)

MCA

MOP

Connection Pipe

Gas additional charge(oz/ft)

Outer Diameter Liquid Pipe (inch)

Outer Diameter Gas Pipe (inch)

Max Height Distance (ft)

Max Length Distance (ft)

1 Sound PRESSURE Level @ 3.3 ft. dB(A)

? 2017 Ingersoll Rand All Rights Reserved

M4THS1509A11N

Swing Rotary

DAPHNE FVC50K (PVE Oil)

16.50

6.60

845

Capillary

0 - 115

-4 - 75

Aluminum Fin-Copper Tube

2/7

1 - 1/18

28 3/4 20

82020

30

0.37

942

15 3/4

Automatic Defrosting

62

52

30 5/9 x 21 1/4 x 12 3/5

33 1/2 x 14 2/7 x 23 3/7

65.0 / 70.6

24.7

9.0

15.0

0.2

1/4

3/8

65

100

Unit Dimensions

W

D

H

6 5/8

18 3/16

6 5/16

09K

9K

2 3/16

2 3/16

2 1/8

2 1/8

6

3 1/2

Unit: inch

MODEL

09K

12K

W

31 1/8

33 1/4

H

10 5/6

11 3/8

28

12 3/5

30 9/16

11 1/4

21 1/4

10 1/8

D

7 7/8

8 1/4

20

Clearance Requirements

Space to the ceiling

6 in.

or more

Space to the wall

6 in. or more

6 in. or more

Space to the wall

118 in.

or more

Air outlet side

66

in.

or more

Space to the floor

The dimensions of the space necessary for correct

installation of the appliance including the minimum

permissible distances to adjacent structures

20 in. or more

Space to the obstruction

Air inlet side

e

or

12

12 in. or more

Space to the wall

Space to the wall

79

in.

or

in.

m

or

20 in. or more

e

or

m

valve cover

Air outlet side

NOTE:

The maximum recommended height from the floor to the bottom of the indoor unit is 11.5 ft. (3.5 m).

Air Velocity Patterns for High Wall

Max Horizontal Distance

Unit: ft. (m)

Model

M4MHW1509A

Cooling Mode

Heating Mode

13.1 (4)

13.1 (4)

Performance Data

COOLING PERFORMANCE

Outdoor

Coil air

DB F

DB C

0

5

14

23

32

41

50

59

68

77

86

95

104

113

\18

\15

\10

\5

0

5

10

15

20

25

30

35

40

45

M4MHW1509A

M4THS1509A

68F DB (20C)

57F WB (14C)

TC

SHC

4400

3550

4900

3900

5600

4400

6100

4900

6450

5100

6650

5250

6950

5450

7500

6100

8500

6950

8500

6950

8000

6650

7650

6300

7150

6100

6800

5800

HEATING PERFORMANCE

DB F

80F DB (27C)

67F WB (19C)

TC

SHC

5250

4250

5800

4600

6800

5450

7650

6100

7650

6100

8000

6300

8350

6650

8850

7150

9700

8000

9550

7800

9350

7650

8850

7500

8700

7300

8350

6950

82F DB (28C)

68F WB (20C)

TC

SHC

5600

4400

5950

4750

6950

5600

8000

6450

8000

6300

8350

6650

8700

6800

9700

7800

10400

8500

10200

8350

10050

8350

9700

8150

9350

7800

9000

7650

M4MHW1509A

M4THS1509A

Heating 9k

Outdoor

Coil air

DB C

\4

0

6

10

16

19

24

32

41

43

47

53

59

64

70

75

73F DB (23C)

61F WB (16C)

TC

SHC

4750

3750

5100

4050

5950

4750

6650

5250

6800

5450

6950

5600

7300

5800

8000

6450

9000

7500

9000

7300

8500

7150

8150

6800

7650

6450

7300

6300

\20

\18

\14

\12

\9

\7

\4

0

5

6

8

12

15

18

21

24

68F DB (20C) 73F DB (23C) 80F DB (27C) 82F DB (28C)

57F WB (14C) 61F WB (16C) 67F WB (19C) 68F WB (20C)

TC

TC

TC

TC

4900

4850

4750

4650

5300

5250

5150

5000

5600

5500

5400

5300

5850

5750

5650

5500

6050

5950

5800

5700

6150

6050

5950

5800

6850

6750

6600

6500

7650

7550

7450

7300

8800

8700

8600

8450

9550

9400

9200

9000

9650

9500

9300

9100

9900

9700

9500

9300

10100

9900

9700

9500

10300

10100

9900

9650

10450

10250

10050

9800

10550

10350

10150

9900

Capacities in these performance tables reflect normal operation at the temperatures indicated. See

specification tables for certified values under prescribed test conditions.

Mechanical Specifications

Mini-Split Outdoor Unit

General

Refrigerant Controls

Condenser Coil

This unit is fully charged from the factory for

up to 25 feet of piping. This unit is designed

to operate at outdoor ambient temperatures

as high as 115F. Cooling capacities with the

mini-split air handler shown in the catalog are

AHRI certified. The unit is ETL listed for outdoor application.

Refrigeration system controls include

condenser fan and compressor relay.

High and low pressure controls are inherent to the compressor. A suction line

multi function service valve is standard

The coil shall consist of aluminum finned

coils brazed to copper tubing. The coil

provides air flow resistance and efficient

heat transfer. The coil is protected by the

casing.

Compressor

Low Ambient Cooling

The compressor features internal over

temperature and pressure protection;

total dipped hermetic motor windings.

Other features include: centrifugal oil

pump and low vibration and noise.

Matched Ameristar ductless products,

have cooling capabilities at outdoor ambient temperatures as low as 0 F.

General

Discharge Airflow and Distribution

System

Remote Controller

The High Wall mounted type air handler

shall be completely factory assembled

including coil, condensate drain pan, fan

motor, washable filter, air purifying filter and

electric controls to be used with a wireless

remote controller. Unit shall be shipped with

a unit mounting plate. Unit shall be matched

with an Ameristar outdoor unit, rated and

tested in accordance with AHRI standard.

Unit shall be ETL listed.

Unit shall have auto swing, dual horizontal blades to optimize the aperture outlet

for vertical airflow and air distribution.

Blade shall close automatically when the

air conditioner is turned off to minimize

dust entering the unit. Five-Step preset

program on the remote controller shall be

available to control the blade angle.

Unit Casing

The unit casing is constructed of heavy

gauge, galvanized steel and painted with a

weather-resistant powder paint.

Mini-Split Indoor High Wall

Unit Casing

Casing shall be provided with knockouts on

the right, and left of the unit to facilitate piping and electrical connection on either side of

the unit. An electrical service cover shall be

provided to permit easy access to the electrical terminal strip.

Manually adjusted wide-angle louvers

shall be provided to adjust the coverage

and direction of airflow.

The unit shall have a wireless infrared remote controller with easy reading digital

display panel to start, stop and regulate

the air conditioner from a distance.

The wireless controller is included with

all units.

Healthy Filters

The unit shall have an active carbon and

catechin filter with the unit.The filters

need to be cleaned at least once a year.

Controls

Units shall have the capability to be controlled remotely through wall-mounted

wired options (sold separately) as well

as a wireless remote option.

06/17

The manufacturer has a policy of continuous product and product data improvement and it reserves the right

to change design and specifications without notice.

................
................

In order to avoid copyright disputes, this page is only a partial summary.