Design Design Standards (English)
|DESIGN DIVISION (ROADWAY STANDARDS) |
|Vincent J. Parker TxDOT CAD Standards Manager 512 416-2656 |
|LIST UPDATED ON 07/13/2016 |
| See List of Roadway Standards ~ rdwindex.dgn |
| |
| |
| |
|NOTE: Click on (rdwindex.pdf or dgn) to view our complete inventory of Roadway Standards |
| |
| |
| |
|MicroStation V8i (SELECTseries3) plot driver file for Xerox printers ~ xerox-b.pltcfg |
|Supporting files (controld) and (ljetb.pro) must reside in the main directory. |
|Memorandums of Issued / Revised Standards |
|From November 2000 to Present |
|DATE |SUBJECT |FILE NAME |
|07-13-16 |New (Guardrail End Terminal) Standard. |memo0716a.pdf |
| |Applicable to November 2016 | |
|07-01-16 |Updated (Temporary Erosion, Control Measures) Standards. |memo0716.pdf |
| |Applicable to November 2016 | |
|04-12-16 |Updated company contact information for the roadside safety devices. |memo0416.pdf |
| |Applicable to July 2016 | |
|03-22-16 |Revised Roadway StandardsApplicable to June 2016 |memo0316.pdf |
|01-21-16 |Revised Roadway StandardsApplicable to April 2016 |memo0116.pdf |
|02-04-15 |Revised Roadway StandardsApplicable to April 2015 |memo0215.pdf |
|12-03-14 |Revised Roadway StandardsApplicable to March 2015 |memo1214.pdf |
|10-28-14 |Revised Roadway StandardsApplicable as of October 28, 2014 |memo1014.pdf |
|08-25-14 |Revised Roadway Standards |memo0814.pdf |
|07-15-14 |Revised Roadway StandardsApplicable to January 2015 Letting |memo0714.pdf |
|04-15-14 |Revised Roadway StandardsApplicable to October 2014 Letting |memo0414.pdf |
|03-03-14 |Revised Roadway Standards |memo0314.pdf |
|10-23-13 |Revised Roadway Standards |memo1013.pdf |
|07-23-13 |Revised Roadway Standards |memo0713.pdf |
|06-04-13 |Revised Roadway Standards |memo0613.pdf |
|05-22-13 |Revised Roadway Standards |memo0513.pdf |
|01-16-13 |Revised Roadway Standards |memo0113.pdf |
|08-22-12 |Revised Roadway Standards |memo0812.pdf |
|06-14-12 |Revised Roadway Standards |memo0612a.pdf |
|06-05-12 |Revised Roadway Standards |memo0612.pdf |
|04-18-12 |Revised Roadway Standards |memo0412.pdf |
|02-28-12 |Revised Roadway Standards |memo0212.pdf |
|12-22-11 |Revised Roadway Standards |memo1211.pdf |
|10-21-11 |Revised Roadway Standards |memo1011.pdf |
|08-04-11 |Revised Roadway Standards |memo0811.pdf |
|05-20-11 |Revised Roadway Standards |memo0511.pdf |
|04-01-11 |Revised Roadway Standards |memo0411.pdf |
|01-31-11 |Revised Roadway Standards |memo0111.pdf |
|12-30-10 |Revised Roadway Standards |memo1210.pdf |
|10-04-10 |Revised Roadway Standards |memo1010.pdf |
|06-14-10 |Revised Roadway Standards |memo0610.pdf |
|05-20-10 |Revised Roadway Standards |memo0510.pdf |
|03-26-10 |Revised Roadway Standards |memo0310.pdf |
|11-23-09 |Revised Roadway Standards |memo1109.pdf |
|09-28-09 |Revised Roadway Standards |memo0909.pdf |
|12-01-06 |Revised Roadway Standards |memo1206.pdf |
|02-01-06 |Revised Roadway Standards (English and Metric) |memo0206.pdf |
|09-01-05 |Revised Roadway Standards (English and Metric) |memo0905.pdf |
|08-02-05 |Revised Roadway Standards (English and Metric) |memo0805.pdf |
|12-01-04 |Revised Roadway Standards (English and Metric) |memo1204.pdf |
|07-01-04 |Revised Roadway Standards (English and Metric) |memo0704.pdf |
|10-10-03 |Revised Roadway Standards (English and Metric) |memo1003.pdf |
|09-03-03 |Revised Roadway Standards (English and Metric) |memo0903.pdf |
|04-01-03 |Revised Roadway Standards (English and Metric) |memo0403.pdf |
|02-03-03 |Revised Roadway Standards (English and Metric) |memo0203.pdf |
|03-01-02 |Revised Roadway Standards (English and Metric) |memo0302.pdf |
|02-01-02 |Revised Roadway Standards (English and Metric) |memo0202.pdf |
|12-03-01 |Revised Roadway Standards (English and Metric) |memo1201.pdf |
|11-01-01 |Revised Roadway Standards (English and Metric) |memo1101.pdf |
|07-31-01 |Revised Roadway Standards (English and Metric) |memo0701.pdf |
|12-29-00 |Revised Roadway Standards (English and Metric) |memo1200.pdf |
|11-30-00 |Revised Roadway Standards (English and Metric) |memo1100.pdf |
| BARRIER (FLEXIBLE) |
|TITLE |DESCRIPTION |FILE NAME |
|GF(31)-14 |Metal Beam Guard Fence |gf3114.dgn |
|GF(31)DAT-14 |Metal Beam Guard Fence(Downstream Anchor Terminal) |gf31dat14.dgn |
|GF(31)LS-14 |Metal Beam Guard Fence(Long Span) |gf31ls14.dgn |
|GF(31)TR-14 |Metal Beam Guard Fence Transition(Thrie Beam Transition) |gf31tr14.dgn |
|GF(31)TL2-11 |Metal Beam Guard Fence Transition(TL2) (Low Speed Transition) |gf31tl211.dgn |
|GF(31)T101-13 |Metal Beam Guard Fence Transition(T101) |gf31t10113.dgn |
|GF(31)T6-14 |Metal Beam Guard Fence Transition(T6) |gf31t614.dgn |
|GF(31)MS-11 |Metal Beam Guard Fence(Mow Strip) |gf31ms11.dgn |
|BED-14 |Bridge End Details(Metal Beam Guard Fence Applications to Rigid Rails) |bed14.dgn |
| |
|BARRIER (RIGID) |
|TITLE |DESCRIPTION |FILE NAME |
|CSB(1)-10 |Concrete Safety Barrier (F-Shape)Precast Barrier (Type 1)2 Sheets |csb110.dgn |
|CSB(2)-13 |Concrete Safety Barrier (F-Shape)Cast-in-Place (Type 1)(Flexible Pavement) |csb213.dgn |
|CSB(3)-16 |Concrete Safety Barrier (F-Shape)Cast-in-Place (Type 1)(Bridge Deck or CRCP) |csb316.dgn |
|CSB(4)-10 |Concrete Safety Barrier (F-Shape)Cast-in-Place (Type 2)At Light Pole |csb410.dgn |
|CSB(6)-10 |Concrete Safety Barrier (F-Shape)Cast-in-Place (Type 3)At Fixed Objects |csb610.dgn |
|CSB(7)-10 |Concrete Safety Barrier (F-Shape)Precast (Type 1)Pinned Placement |csb710.dgn |
|CSB(8)-10 |Concrete Safety Barrier (F-Shape)Precast (Type 4)(10 Foot, Barrier Segment) |csb810.dgn |
|SSCB(1)-16 |Single Slope Concrete BarrierCast-in-Place (Type 1)(Bridge Deck or CRCP) |sscb116.dgn |
|SSCB(1F)-10 |Single Slope Concrete BarrierCast-in-Place (Type1)(Flexible Pavement) |sscb1f10.dgn |
|SSCB(2)-10 |Single Slope Concrete BarrierPrecast (Type 1)2 Sheets |sscb210.dgn |
|SSCB(3)-10 |Single Slope Concrete BarrierCast-in-Place (Type 3)At Fixed Objects |sscb310.dgn |
|SSCB(4)-10 |Single Slope Concrete BarrierCast-in-Place (Type 4)At Light Pole |sscb410.dgn |
|SSCB(5)-10 |Single Slope Concrete BarrierPrecast (Type 1)Pinned Placement |sscb510.dgn |
|LPCB-13 |Low Profile Concrete BarrierPrecast (Type 1) and (Type 2)2 Sheets |lpcb13.dgn |
|FSLP(TR)-10 |F-Shape to Low ProfilePrecast Barrier Transition (Type T)2 Sheets |fslptr10.dgn |
|BG-11 |Barrier Gate2 Sheets |bg11.dgn |
| |
|BARRIER (STEEL) |
|TITLE |DESCRIPTION |FILE NAME |
|BARRIERGUARD-14 |BarrierGuard 800 System (Steel Barrier) |barrierguard14.dgn |
|VULCAN-14 |Vulcan System (Steel Barrier) |vulcan14.dgn |
|ZONEGUARD-14 |ZoneGuard System (Steel Barrier) |zoneguard14.dgn |
| |
|GUARDRAIL END TREATMENTS |
|TITLE |
|DESCRIPTION |
|FILE NAME |
| |
|SGT(8)31-14 |
|Single Guardrail Terminal (SKT 350)(Wood Post) |
|sgt83114.dgn |
| |
|SGT(8S)31-14 |
|Single Guardrail Terminal (SKT 350)(Hinged Steel Post) |
|sgt8s3114.dgn |
| |
|SGT(9S)31-14 |
|Single Guardrail Terminal (X-LITE)(Steel Post) |
|sgt9s3114.dgn |
| |
|SGT(10S)31-16 |
|Single Guardrail Terminal (SOFTSTOP)(Steel Post) |
|sgt10s3116.dgn |
| |
| |
|ATTENUATORS / CRASH CUSHIONS |
|TITLE |DESCRIPTION |FILE NAME |
|SSCC-16 |Single Sided Crash Cushion(BEAT-SSCC) |sscc16.dgn |
|CATCB(1)-16 |Crash Cushion Attenuating Terminal Details2 Sheets |catcb16.dgn |
|CATGR(1)-16 |Crash Cushion Attenuating Terminal Details2 Sheets |catgr16.dgn |
|QUAD(N)-16 |Quadguard II System(Narrow) |quadn16.dgn |
|QUAD(W)-16 |Quadguard II System(Wide) |quadw16.dgn |
|QUEST-16 |Quest System |quest16.dgn |
|QGELITE(N)-16 |Quadguard (ELITE) System(Narrow) |qgeltn16.dgn |
|QGELITE(W)-16 |Quadguard (ELITE) System(Wide) |qgeltw16.dgn |
|REACT(N)-16 |Reusable Energy Absorbing Crash Terminal(REACT 350 & REACT 350 II)(Narrow) |reactn16.dgn |
|REACT(W)-16 |Reusable Energy Absorbing Crash Terminal(REACT 350)(Wide) |reactw16.dgn |
|SMTC(N)-16 |Smart Cushion(Narrow) |smtcn16.dgn |
|SMTC(W)-16 |Smart Cushion(Wide) |smtcw16.dgn |
|TRACC(N)-16 |Trinity Attenuating Crash Cushion(Narrow TRACC Systems)(FASTRACC, TRACC, SHORTRACC) |traccn16.dgn |
|TRACC(W)-16 |Trinity Attenuating Crash Cushion(Wide TRACC Systems)(FASTRACC, TRACC, SHORTRACC) |traccw16.dgn |
|HEART-16 |Hybrid Energy Absorbing Terminal |heart16.dgn |
|TAU-II(N)-16 |Barrier Systems Attenuating Crash Cushion(Narrow) |tauiin16.dgn |
|TAU-II(W)-16 |Barrier Systems Attenuating Crash Cushion(Wide) |tauiiw16.dgn |
|TAU-II-R(N)-16 |Barrier Systems Attenuating Crash Cushion(R-Narrow) |tauiirn16.dgn |
|TAU-II-R(W)-16 |Barrier Systems Attenuating Crash Cushion(R-Wide) |tauiirw16.dgn |
|ABSORB-16 |Barrier Systems Attenuating Crash Cushion(ABSORB 350 System)(FOR TEMPORARY WORK ZONE|absorb16.dgn |
| |USE ONLY) | |
|ACZ(350)-16 |Energy Absorption Crash Cushion(ACZ 350 System)(FOR TEMPORARY WORK ZONE USE ONLY) |acz35016.dgn |
|SLED-14 |SLED Crash Cushion(FOR TEMPORARY WORK ZONE USE ONLY) |sled14.dgn |
|VIA(SFPM)-13 |Vehicle Impact Attenuator(SAND FILLED PLASTIC MODULES) |viasfpm13.dgn |
| |
|CABLE BARRIER SYSTEMS |
| |
| |
| |
|TITLE |
|DESCRIPTION |
|FILE NAME |
| |
|BRIFEN(TL4)-14 |
|Brifen Wire Rope Safety Fence (TL-4)3 Sheets |
|brifentl414.dgn |
| |
|CASS(TL3)-14 |
|Trinity Cable Safety System (TL-3) |
|casstl314.dgn |
| |
|CASS(TL4)-14 |
|Trinity Cable Safety System (TL-4) |
|casstl414.dgn |
| |
|GBRLTR(TL3)-14 |
|Gibraltar Cable Barrier System (TL-3) |
|gbrltrtl314.dgn |
| |
|GBRLTR(TL4)-14 |
|Gibraltar Cable Barrier System (TL-4) |
|gbrltrtl414.dgn |
| |
|NU-CABLE(TL3)-14 |
|NU-Cable Barrier System (TL-3) (3 OR 4 Cable)2 Sheets |
|nucabletl314.dgn |
| |
|NU-CABLE(TL4)-14 |
|NU-Cable Barrier System (TL-4) (4 Cable)2 Sheets |
|nucabletl414.dgn |
| |
| |
| |
|PAVEMENTS |
|TITLE |DESCRIPTION |FILE NAME |
|TE(HMAC)-11 |Tapered Edge Details HMAC Pavement |tehmac11.dgn |
|TWT-04 |Thin Whitetopping Details |twt04.dgn |
|CRCP(1)-13 |Continuously Reinforced Concrete PavementOne Layer Steel Bar Placement2 Sheets |crcp113.dgn |
|CRCP(2)-13 |Continuously Reinforced Concrete PavementTwo Layer Steel Bar Placement2 Sheets |crcp213.dgn |
|REPCP-14 |Repair of Concrete Pavement2 Sheets |repcp14.dgn |
|CPCD-14 |Concrete Pavement Details, Contraction Design2 Sheets |cpcd14.dgn |
|JS-14 |Concrete Paving Details, Joint Seals |js14.dgn |
| |
|TEMPORARY EROSION |
|TITLE |DESCRIPTION |FILE NAME |
|EC(1)-16 |Temporary Erosion, Control Measures(Fence & Vertical Tracking) |ec116.dgn |
|EC(2)-16 |Temporary Erosion, Control Measures(Rock Filter Dams) |ec216.dgn |
|EC(3)-16 |Temporary Erosion, Control Measures(Construction Exits) |ec316.dgn |
|EC(4)-16 |Temporary Erosion, Control Measures(Dikes, Earthwork for Erosion Control) |ec416.dgn |
|EC(5)-16 |Temporary Erosion, Control Measures(Swales, Earthwork for Erosion Control) |ec516.dgn |
|EC(6)-16 |Temporary Erosion, Control Measures(Sediment Basins & Traps, Earthwork for Erosion |ec616.dgn |
| |Control) | |
|EC(7)-16 |Temporary Erosion, Control Measures(Temporary Pipe Slope Drains) |ec716.dgn |
|EC(8)-16 |Temporary Erosion, Control Measures(Temporary Paved Flumes) |ec816.dgn |
|EC(9)-16 |Temporary Erosion, Control Measures(Erosion Control Log)3 Sheets |ec916.dgn |
| |
|MISCELLANEOUS |
|TITLE |DESCRIPTION |FILE NAME |
|CCCG-12 |CONCRETE CURB AND CURB AND GUTTER |cccg12.dgn |
|PED-12A |PEDESTRIAN FACILITIES4 SHEETS |ped12a.dgn |
|PRD-13 |PEDESTRIAN HANDRAIL DETAILS3 SHEETS |prd13.dgn |
|M-10 |RIGHT-OF-WAY MARKER |m10.dgn |
|CLF-10 |CHAIN LINK FENCE |clf10.dgn |
|WF(1)-10 |BARBED WIRE FENCE AND WOVEN WIRE FENCE(WOOD POSTS) |wf110.dgn |
|WF(2)-10 |BARBED WIRE FENCE AND WOVEN WIRE FENCE(STEEL POSTS) |wf210.dgn |
| |
|INTERIM (28 INCH) BARRIER (FLEXIBLE) |
|TITLE |
|DESCRIPTION |
|FILE NAME |
| |
|MBGF-11 |
|METAL BEAM GUARD FENCE |
|mbgf11.dgn |
| |
|MBGF(SR)-11 |
|METAL BEAM GUARD FENCE(SHORT RADIUS) |
|mbgfsr11.dgn |
| |
|MBGF(TR)-11 |
|METAL BEAM GUARD FENCE TRANSITION(THRIE BEAM TRANSITION) |
|mbgftr11.dgn |
| |
|MBGF(TL2)-11 |
|METAL BEAM GUARD FENCE TRANSITION(TL2) (LOW SPEED TRANSITION) |
|mbgtl211.dgn |
| |
|MBGF(T101)-11 |
|METAL BEAM GUARD FENCE TRANSITION(T101 BRIDGE RAIL) |
|mbgft111.dgn |
| |
|MBGF(MS)-11 |
|METAL BEAM GUARD FENCE(MOW STRIP) |
|mbgfms11.dgn |
| |
|BED(28)-11 |
|BRIDGE END DETAILS(28” METAL BEAM GUARD FENCE APPLICATIONS TO RIGID RAILS) |
|bed2811.dgn |
| |
|SGT(8)-14 |
|SINGLE GUARDRAIL TERMINAL (SKT 350)(WOOD POST) |
|sgt814.dgn |
| |
|SGT(8)H-14 |
|SINGLE GUARDRAIL TERMINAL (SKT 350)(HINGED STEEL POST) |
|sgt8h14.dgn |
| |
|SGT(9S)-14 |
|SINGLE GUARDRAIL TERMINAL (X-LITE)(STEEL POST) |
|sgt9s14.dgn |
| |
| |
|DESIGN DETAILS |
|TITLE |DESCRIPTION |FILE NAME |
|1990 MAILBOX TURNOUT DETAIL |mbtrnout.dgn |
|2015 ENVIRONMENTAL PERMITS, ISSUES AND COMMITMENTS |epic.dgn |
|2012 ENVIRONMENTAL MANAGEMENT SYSTEM GUIDANCE DOCUMENT |epic(guide).pdf |
|2014 SEAL COAT MATERIAL SELECTION TABLE |sctable.dgn |
|2011 BARRIER GATE (FABRICATION DETAILS) |bg(fd).pdf |
|2013 CRASH CUSHION SUMMARY SHEET |ccss.dgn |
Vincent J. Parker TxDOT Roadway Standards CAD Manager
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- roadway design checklist tennessee
- design review checklist ldrc
- design design standards english
- minnesota department of transportation mndot
- attachment to bts letter transportation
- wsdot design manual chapter revision
- transportation research board
- home us forest service
- sp11 r002 ncdot
- transportation enhancement activities georgia
Related searches
- joint commission standards time out
- standards for the teaching profession
- birth to five standards louisiana
- hud minimum property standards 2019
- highest standards synonym
- third grade ela standards california
- set high standards synonyms
- common core standards ela 3rd grade
- cms standards for verbal orders
- high standards synonym
- early learning standards louisiana
- having high standards meaning