24W Switching Power Adapter - Circuit Test
24W
Switching Power Adapter
SPECIFICATIONS
Model No. £º
RPR-2401A0-P5
Description £º
24 Volts / 1.0 Amps
Version
£º
1.0
Date
£º
28-Aug.-2008
8061 North Fraser Way
Burnaby, BC, Canada V5J 5M8
Phone: 604-482-5210 ? Fax: 604-738-3002
? info@
Page 1 of 8
CIRCUIT-TEST
ELECTRONICS
1. Feature£º
Input
£º Universal 100 ~ 240 Vac / 47 ~ 63 Hz Input, without any slide switch.
Output
£º +24V / 0~1 A
Case Dimension
£º 72(L) * 34 (W) * 69 (H) mm
Efficiency
£º Eff (av)
Safety
£º UL / CUL / PSE / BSMI
EMI
£º FCC
Protection
£º
>
=
78.6 % Min.
Class B £» Conduction £¦ Radiation Met.
OVP (Over Voltage Protection) SCP (Short Circuit Protection)
OCP (Over Current Protection)
High frequency design£¬less power consumption.
Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System.
Meet CEC Specification .
2. Input£º
2.1
Voltage
Universal 100~240Vac, single phase
2.2
Frequency
47 ~ 63 Hz
2.3
Current
2.4
Inrush Current
0.58A Max.
30A Max. / 100Vac £» 45A Max. / 240Vac
(Cold Start At 25 ?C£¬Full Load)
2.5
Efficiency
Eff (av)
2.6
Power Consumption
Pi
£½
78.6 % Min. (At 115 Vac & 230 Vac)
0.5 W ( At 240Vac & No Load)
E1 + E2 + E3 + E4
E1=efficiency with 25% rated load ; E2= efficiency with 50% rated load
4
E3=efficiency with 75% rated load ; E4= efficiency with 100% rated load
3. Output£º
3.1
DC Output
Voltage
+24V ¡À 5%
Current
1.0A Max.
Regulation
22.8Vmin. ~ 24.0Vtyp. ~ 25.2Vmax.
Ripple & Noise
100 mV Max.
Total Power
24W Max.
Remark : For ripple & noise measurement, use a 20MHz bandwidth frequency oscilloscope, and add a 0.1?F multilayer Cap. and a
Low ESR Electrolytic Cap. (10 ?F ) at output connector terminals. (At nominal line voltage, Full Load)
Page 2 of 8
CIRCUIT-TEST
ELECTRONICS
4. Protection :
4.1
Over Voltage Protection (OVP)
27V ( Max. )
4.2
Short Circuit Protection (SCP)
Automatic recovery after short-circuit fault being removed
4.3
Over Current Protection(OCP)
2.5A (MAX)
Remark £º When Short Circuit Protection or Over Current Protection is activated,the power supply will shutdown automatically.
Once the abnormal condition resulting in the failure being removed, the power supply will restart accordingly. When
Over Voltage Protection is activated, the power supply will shutdown forever.
5. Safety EMI and EMC Requirement£º
5.1 Safety Requirement
a. Safety
b. Dielectric Strength
£º UL / CUL / PSE / BSMI
£º 10mA Max. Cut off current
(1)
Primary to Secondary
3000Vac
for 1 Minute
(2)
Primary to Frame Ground
1500Vac
for 1 Minute
c. Insulation Resistance
£º
(1)
Primary to Secondary
10 M Ohm
for 500Vdc
(2)
Primary to Frame Ground
10 M Ohm
for 500Vdc
5.2 EMI Requirement
£º FCC
Class B £» Conduction £¦ Radiation Met.
5.3 Leakage Current
£º Less than 0.25mA
6. Operation and Environment Performance£º
6.1 Temperature Range
Operating
Storage
+ 0?C ~
+ 40?C
- 20 ?C
~
+ 70 ?C
15%
~
95% RH
5%
~
95% RH
6.2 Humidity Range(Non-condensing)
Operating
Storage
6.3 Cooling£ºBy natural air
7. M.T.B.F.£º100,000 Hrs.( At 25?C£¬Full Load )
Page 3 of 8
CIRCUIT-TEST
ELECTRONICS
Page 4 of 8
CIRCUIT-TEST
ELECTRONICS
Page 5 of 8
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- medite global 5w switch mode power adapter
- switch on semiconductor
- switching power supply technical manual
- switching power supply
- powering electronics from the usb port
- poe adapters datasheet
- midway power supply upgrade kit
- 24w switching power adapter circuit test
- ac dc switch mode power supply design guide
- product sheet adapter fsp150 xxxn3 v2
Related searches
- power in a circuit formula
- power in circuit formula
- parallel circuit power calculator
- ac adapter power supply cord
- 24v ac adapter power supply
- ac dc switching power supply
- what is a switching adapter used for
- 12v dc adapter power supply
- switching adapter 100 240v
- 24v switching power supply
- constant current switching power supply
- power of the test calculator