24W Switching Power Adapter - Circuit Test

24W

Switching Power Adapter

SPECIFICATIONS

Model No. £º

RPR-2401A0-P5

Description £º

24 Volts / 1.0 Amps

Version

£º

1.0

Date

£º

28-Aug.-2008

8061 North Fraser Way

Burnaby, BC, Canada V5J 5M8

Phone: 604-482-5210 ? Fax: 604-738-3002

? info@

Page 1 of 8

CIRCUIT-TEST

ELECTRONICS

1. Feature£º

Input

£º Universal 100 ~ 240 Vac / 47 ~ 63 Hz Input, without any slide switch.

Output

£º +24V / 0~1 A

Case Dimension

£º 72(L) * 34 (W) * 69 (H) mm

Efficiency

£º Eff (av)

Safety

£º UL / CUL / PSE / BSMI

EMI

£º FCC

Protection

£º

>

=

78.6 % Min.

Class B £» Conduction £¦ Radiation Met.

OVP (Over Voltage Protection) SCP (Short Circuit Protection)

OCP (Over Current Protection)

High frequency design£¬less power consumption.

Suitable for usage at Telecommunication, Computer, Industrial Controller, & OA System.

Meet CEC Specification .

2. Input£º

2.1

Voltage

Universal 100~240Vac, single phase

2.2

Frequency

47 ~ 63 Hz

2.3

Current

2.4

Inrush Current

0.58A Max.

30A Max. / 100Vac £» 45A Max. / 240Vac

(Cold Start At 25 ?C£¬Full Load)

2.5

Efficiency

Eff (av)

2.6

Power Consumption

Pi

£½

78.6 % Min. (At 115 Vac & 230 Vac)

0.5 W ( At 240Vac & No Load)

E1 + E2 + E3 + E4

E1=efficiency with 25% rated load ; E2= efficiency with 50% rated load

4

E3=efficiency with 75% rated load ; E4= efficiency with 100% rated load

3. Output£º

3.1

DC Output

Voltage

+24V ¡À 5%

Current

1.0A Max.

Regulation

22.8Vmin. ~ 24.0Vtyp. ~ 25.2Vmax.

Ripple & Noise

100 mV Max.

Total Power

24W Max.

Remark : For ripple & noise measurement, use a 20MHz bandwidth frequency oscilloscope, and add a 0.1?F multilayer Cap. and a

Low ESR Electrolytic Cap. (10 ?F ) at output connector terminals. (At nominal line voltage, Full Load)

Page 2 of 8

CIRCUIT-TEST

ELECTRONICS

4. Protection :

4.1

Over Voltage Protection (OVP)

27V ( Max. )

4.2

Short Circuit Protection (SCP)

Automatic recovery after short-circuit fault being removed

4.3

Over Current Protection(OCP)

2.5A (MAX)

Remark £º When Short Circuit Protection or Over Current Protection is activated,the power supply will shutdown automatically.

Once the abnormal condition resulting in the failure being removed, the power supply will restart accordingly. When

Over Voltage Protection is activated, the power supply will shutdown forever.

5. Safety EMI and EMC Requirement£º

5.1 Safety Requirement

a. Safety

b. Dielectric Strength

£º UL / CUL / PSE / BSMI

£º 10mA Max. Cut off current

(1)

Primary to Secondary

3000Vac

for 1 Minute

(2)

Primary to Frame Ground

1500Vac

for 1 Minute

c. Insulation Resistance

£º

(1)

Primary to Secondary

10 M Ohm

for 500Vdc

(2)

Primary to Frame Ground

10 M Ohm

for 500Vdc

5.2 EMI Requirement

£º FCC

Class B £» Conduction £¦ Radiation Met.

5.3 Leakage Current

£º Less than 0.25mA

6. Operation and Environment Performance£º

6.1 Temperature Range

Operating

Storage

+ 0?C ~

+ 40?C

- 20 ?C

~

+ 70 ?C

15%

~

95% RH

5%

~

95% RH

6.2 Humidity Range(Non-condensing)

Operating

Storage

6.3 Cooling£ºBy natural air

7. M.T.B.F.£º100,000 Hrs.( At 25?C£¬Full Load )

Page 3 of 8

CIRCUIT-TEST

ELECTRONICS

Page 4 of 8

CIRCUIT-TEST

ELECTRONICS

Page 5 of 8

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download