LT0256 F3200/NDU/ADU AS4428.1 PROGRAMMING MANUAL



APPENDIX B

ADU CONFIGURATION SHEETS

The following pages are suggested as master forms for programming the ADU. It is recommended that they be photocopied, and a complete set be filled out for each ADU before programming is started.

When programming is complete, the forms should be checked against a database printout.

A copy of the database printout, completed forms and database disk file should be kept in the contract file for each installation.

ADU SYSTEM CONFIGURATION PAGE 1 REF:...............

This set of configuration sheets contains all programmable parameters. Fill in values for all parameters that are being changed from the default settings.

System/project name ................................................................................

ADU site name .............................................................................................

(40 characters max.)

Fault action text ……………………………………………………………

(40 characters max.)

|SYSTEM PARAMETERS |

|Operating mode |NSA / Compact FF | |

|Connection type |Panel-link network / RZDU | |

|Door-switch is wired to input 3 |Yes / No | |

|New Zealand mode |Enable / disable | |

|MCP Zone (Panel-link mode only). (zero is no |0 - 16 | |

|MCP) | | |

|FF OPTIONS |

|FF auto ack enable/disable |Yes / No | |

|FF display cause by default |Yes / No | |

|FF multiple cause updates |Yes / No | |

|FF switch to newest alarm |Yes / No | |

|FF show zone number |Yes / No | |

|FF new cause new alarm |Yes / No | |

|FF show isolated alarms |Yes / No | |

|FF zone alarm shows point text |Yes / No | |

|FF OPTIONS FOR PANEL-LINK CONNECTION TYPE |

|FF zones |MAF only/ all/ none | |

| | | |

|FF OPTIONS FOR RZDU CONNECTION TYPE |

|FF show FIP zone names |Yes / No | |

|FF alarm source messages |LED; LCD; Both | |

|Global ack command |Enable/disable | |

|Global reset command |Enable/disable | |

|Global isolate command |Enable/disable | |

| | | |

ADU SYSTEM CONFIGURATION PAGE 2 REF:...............

|SYSTEM PARAMETERS FOR RZDU CONNECTION TYPE |

|Address |1 - 8 | |

|FF Mode |AS4428.1 / AS1603.4 | |

|Legacy bells |WarnSys, ExtBell, None | |

|Mimic mode |Enable/disable | |

|Protocol type |LCD-A / Non-LCD | |

|MCP connected to input 1 |Yes / No | |

|Capture remote time/date |Enable/disable | |

|Capture FIP zone names from alarms |Enable/disable | |

|Common LEDs show local status |Yes / No | |

|Common LEDs show FIP status |Yes / No | |

|Warning system isolate |Control/ follow/ local | |

|External bell isolate |Control/ follow/ local | |

|Follow FIP alarm buzzer |Yes / No | |

|Follow FIP fault buzzer |Yes / No | |

|BUZZER OPTIONS |

|Zone alarm buzzer enable |Y/N | |Remote sys fault reset silences |Y/N | |

|Zone fault buzzer enable |Y/N | |Remote FF action silences |Y/N | |

|System fault buzzer enable |Y/N | |Remote any command silences |Y/N | |

|Non-MAF zone faults buzzer |Y/N | |Receive network sounder silence |Y/N | |

|Faults resound after 8 hours |Y/N | |Any key TX sounder silence |Y/N | |

|Sounder after 8 hours isolate |Y/N | |Cmd TX sounder silence |Y/N | |

|Sounder “8 hour” resound period | | | | | |

|ACCESS CODES 0 - 9 |

|USER INITIALS |

|0 |1 |2 |3 |4 |5 |6 |7 |8 |9 |

| | | | | | | | | | |

| AUTO TEST | ALARM | | TIME | | DATES | |

ADU SYSTEM CONFIGURATION PAGE 3 REF:...............

KEY ENABLE/DISABLE

|Key |Non-FF Mode Door Open |FF Mode |Non-FF Mode |FF Mode |

| |Key Enabled Y/N |Door Open |Door Closed |Door Closed |

| | |Key Enabled |Key Enabled Y/N |Key Enabled |

| | |Y/N | |Y/N |

|Prev | | | | |

|Next | | | | |

|Ack | | | | |

|Reset | | | | |

|Isolate | | | | |

|External Bell Isol | | | | |

|Warn Sys Isol | | | | |

EVENT LOGGING

|Event printing enable/disable Y/N | |

|Printer lines per page 0 – 250 | |

|Printer baud rate 300 – 9600 | |

|Print relay activate/de-activate events Y/N | |

EVENT TYPES LOGGED TO PRINTER AND HISTORY

| |PRINTER Y/N |HISTORY Y/N |

|ZONES | | |

|SYSTEM | | |

|SYS RUN | | |

|CIRCUIT | | |

|POINT | | |

|RELAY | | |

ADU SYSTEM CONFIGURATION PAGE 4 REF:...............

DAYLIGHT SAVING PARAMETERS

| |START |END |

|MONTH | | |

|HOUR | | |

|MINUTE | | |

|DAY: (one of next 1,2,3) | | |

|1: LAST WEEKDAY OF | | |

|(MON-SUN) | | |

|2: Nth WEEKDAY OF | | |

|(MON-SUN) | | |

|3: DATE | | |

|TIME DIFFERENCE: | | |

| HOUR | | |

| MINUTE | | |

FF ZONE GLOBAL OPTIONS

|Map |Alm |Multi |Ack |Ack |Loc |Reset |Iso |

|FF |Sndr |Alm |Tx |Rx |Ack |FF |FF |

|Y/N |Y/N |Y/N |Y/N |Y/N |Y/N |Y/N |Y/N |

| | | | | | | | |

|Hide |Log |Total |Alarm |Fault |Output | | |

|Y/N |Y/N |Y/N |test |test |type | | |

| | | |Y/N |Y/N |Y/N | | |

| | | | | | | | |

ADU CONFIGURATION REF:...............

FF ZONE OPTIONS

|SID | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

| | | | | | | | | |

ADU ZONE CONFIGURATION REF:...............

PANEL-LINK MODE

| |ZONE PROGRAMMING |ZONE NAME |

| | | |

| | | |

|ZONE NO | | |

| |LATCH|MAF |ANC1 |WARN |EXT |LED | |

| | | | |SYS |BELL | | |

|Defaults |L |M |M |M |M |ZONE | |

| | | | | | |NO. | |

| |1 | | | | | | | |

| |2 | | | | | | | |

| |3 | | | | | | | |

|1 |4 | | | | | | | |

| |5 | | | | | | | |

| |6 | | | | | | | |

| |7 | | | | | | | |

| |8 | | | | | | | |

| |9 | | | | | | | |

| |10 | | | | | | | |

| |11 | | | | | | | |

|2 |12 | | | | | | | |

| |13 | | | | | | | |

| |14 | | | | | | | |

| |15 | | | | | | | |

| |16 | | | | | | | |

ADU TIMERS, VARIABLES, REF:...............

NETWORK VARIABLES &

ZONE ISOLATE/DEISOLATE/RESET EQUATIONS

|TIMER/VARIABLE/ | |

|NETVARS/ZONE CMD |LOGIC EQUATION |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

ADU PANEL-LINK NETWORK CONFIGURATION REF:...............

FILL IN VALUES FOR ALL PARAMETERS THAT ARE BEING CHANGED FROM DEFAULT.

|NETWORK SETUP |

|NETWORK ENABLED (Y/N) | |POINT ACCESS (Y/N) | | | |

|LOCAL SID NUMBER | |NIC Y/N | |RX TIMEOUT | |

|TX DELAY | |ACK TIME | |DUP TIME | |

|LEADING FF | |TRAILING FF | |LINK TX Y/N | |

|LINK TX TIME | |LINK RX TIME | |GROUPS | |

|ACK BROADCASTS Y/N | |BAUD RATE | |RETRIES | |

|SLOTS | |MODE B 0 – 7 | |ACK BROADCASTS | |

|MODE: MULTIDROP/POINT TO POINT M/P | |TO SPECIFIC SID | |

| |

|NETWORK COMMAND CONFIG |

|ACK TIME | |WORK TIME | |RX NET TIME/DATE Y/N | |

|TX NET TIME/DATE Y/N | | |

| |

|NETWORK FF CONFIG |

|TX ALARMS Y/N | |DEDICATED TX SID | | | |

| |

|NETWORK EVENT CONFIG |

|TRANSMIT EVENTS Y/N | |TRANSMIT EVENT UPDATES Y/N | |

|TRANSMIT RELAY OPERATES Y/N | |ZONE/RELAY CMD TEXT TX Y/N | |

|ZONE/RLY EVENT TEXT TX Y/N | |SYSTEM EVENT TEXT TX Y/N | |

| |

|NETWORK VARIABLE CONFIG |

|TX ENABLED Y/N | |TX REFRESH RATE | |MAX COS TX RATE | |

| |

|NETWORK STATUS REFRESH CONFIG |

|REFRESH ENABLED Y/N | |TX REFRESH RATE | |FAST TX RATE | |

ADU CONFIGURATION REF:...............

ZONE NAMES (RZDU CONNECTION MODE)

|ZONE NUMBER |ZONE NAME (MAX 30 CHARACTERS) |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

| | |

THIS PAGE INTENTIONALLY LEFT BLANK

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download