TEMPERATURE ACTUATED WATER REGULATING VALVES
TEMPERATURE ACTUATED WATER REGULATING VALVES
Type OWR, HWR & XWR
GENERAL DESCRIPTION
? Type OWR: 2-way temp. actuated water regulating valves, open on temperature rise. Type HWR: 2-way temp. actuated water regulating valves, open on temperature decrease. Type XWR: 3-way temp. actuated water regulating valves.
? Temperature sensing element (type OWR, HWR & XWR) Capil. tube: 1000mm2.4
? Body material: Bronze for water and brine, cast iron for water only
TYPE NUMBER SELECTION (SPECIFICATIONS)
Type OWR
Type XWR
TEMPERATURE ACTUATED VALVES 2?WAY
Catalog No.
Valve Body Material
Connection
Size
Style
5004 G
1/2"
5006 G
3/4"
Bronze
Rc
5010 G
1"
Temp. Range
(?C)
Max. Water Temp. (?C)
Max. Water Press.
Max. Bulb Temp. (?C)
Bulb Size (mm)
Unit: MPa {kgf/cm2}
Factory Setting (?C)
Wt. (kg)
1.0 19150
1.2
2.0
5012 G
1?1/4"
30 to 50
80
19320
40
2.2
5014 F
1?1/2"
11.5
OWR? HWR?
5020 F 5024 F 7504 G 7506 G 7510 G
Cast Iron Bronze
2" 2?1/2"
1/2" 3/4" 1"
Flange Rc
60
0.98 {10}
18.3 32350
22.2 1.0
19150 1.2 2.0
7512 G
1?1/4"
50 to 75
100 19320
60
2.2
7514 F
1?1/2"
11.5
7520 F 7524 F
Cast Iron
2" 2?1/2"
Flange
18.3 32350
22.2
Pressure at which valve starts opening. OWR & HWR with flange connection are supplied with JIS 10K (0.98 MPa) round companion flanges (JIS B2220 2239) and bolt/nuts. Capillary tube ... Standard 1 meter, optional 1.5, 2 and 3 meters
TEMPERATURE ACTUATED VALVES 3?WAY
Catalog No.
Valve Body Material
Connection
Style
Size
5004 G
1/2"
5006 G
3/4"
5010 G
1"
XWR?
5012 G 7504 G
Bronze
1?1/4" Rc
1/2"
7506 G
3/4"
7510 G
1"
7512 G
1?1/4"
Pressure at which valve starts opening. Capillary tube ... Standard 1 meter, optional 1.5, 2 and 3 meters
Temp. Range
(?C)
Max. Water Temp. (?C)
Max. Water Press.
30 to 50
60
0.98 {10}
50 to 75
Max. Bulb Temp. (?C)
80
100
Bulb Size (mm)
Unit: MPa {kgf/cm2}
Factory Setting (?C)
Wt. (kg)
1.0 19150
1.5 40
2.5 19320
3.0
1.1 19150
1.5 60
2.5 19320
3.0
VALVE ACTION
Set Point is pressure for valve opening. Each cheractaristic of valves is different as follows.
'MPX 083
'MPX )83
'MPX 983
.BJO-JOF
4FU1PJOU
1SFTT
1SFTT 4FU1PJOU
4FU1PJOU
#ZQBTT-JOF
1SFTT
ADJUSTMENT
One full turn of adjusting screw changes pressure setting as shown below.
Catalog No.
Change in Temp. Setting
04G
OWR?
06G
HWR?
XWR?
10G
12G
Approx. 4.0?C Approx. 3.0?C
14F
OWR? HWR?
20F
24F
Approx. 4.0?C
87
FLOW CAPACITY
Flow Capacity shows respectively opening temp. diff. at horizontal axis and flow rate of cooling water at vertical axis considering water press. diff. before and behind a valve with 0.1 MPa. (press. diff. between inlet and outlet of valve) In case of water press. diff. before and behind a valve is excepting for 0.1MPa, value is calculated multipling by coefficient in compensation table.
Type OWR, HWR
Type XWR
water pressure difference before and behind a valve: 0.1MPa
water pressure difference before and behind a valve: 0.1MPa
(bypass side)
(bypass side)
(bypass side)
(main side) (main side) (main side)
Flow volume
Flow volume
(bypass side)
(main side)
%)FYXJEUIBDSPTTGMBUT
I I
Valve Opening Temp. Diff. (^)
Valve Opening Temp. Diff. means difference between valve opening temp.(Setting Temp.) and actual working temp..
Please avoid to apply to this range constantly. Valve Opening Temp.(Gas temperature when valve opening)
DIMENSIONS
Type OWR, HWR?G $
Type OWR?F, HWR $
)
*OMFU
*OMFU
)
' '
'
%)FYXJEUIBDSPTTGMBUT
I
I
-
$BQJMMBSZ5VCF
Type XWR $
$BQJMMBSZ5VCF
)
*OMFU
0VUMFU
#MJOE1MVH
.BJO
0VUMFU
#ZQBTT
Temp. diff. between operating temp.(^) and value opening tem.
Please avoid to apply to this range constantly. Setting Range(Point)(Valve Opening Temp.)
COMPENSATION COEFFICIENTS
Press. Drop Across Valve:MPa {kgf/cm2}
0.2 {2} 0.1 {1} 0.03 {0.3} 0.05 {0.5} 0.07 {0.7}
Coefficient
1.4 1 0.55 0.7 0.8
Catalog No.
Unit: mm
D
L
H
h C
5004 G
27 70 100
83
42
5006 G
32 80 104
87
5010 G
40 90 116
97
5012 G
50 100 121 102
59
5014 F
-- 148 125 105
5020 F
-- 173
180 155
89
OWR? 5024 F
-- 179
HWR? 7504 G
27 70 100
83
42
7506 G
32 80 104
87
7510 G
40 90 116
97
7512 G
50 100 121 102
59
7514 F
-- 148 125 106
7520 F
173
--
180 155
89
7524 F
179
Catalog No.
Unit: mm
D
L
H
h
h1 C
5004G 27 70 100 31 83 42
5006G 32 80 104 39 87
5010G 40 90 116 44 97 59
5012G 50 100 121 54 102 XWR?
7504G 27 70 100 31 83 42
7506G 32 80 104 39 87
7510G 40 90 116 44 97 59
7512G 50 100 121 54 102
-
Unit: mm
$BQJMMBSZ5VCF
TORONTO, ON TEL: (905) 737-2113 FAX: (905) 737-7319
ecotherm.ca
MONTREAL, QC TEL: (514) 685-5113 FAX: (514) 685-5119
1-866-HVACMAX (482-2629)
VERNON, BC TEL: (250) 549-9162
FAX: (250) 54898-9182
sales@ecotherm.ca
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- v47 series temperature actuated modulating valve catalog
- temperature actuated water regulating valves
- v47 series temperature actuated modulating water valves
- eyewash installation guidelines
- section 22 05 23 general duty valves for plumbing
- section 232500 hvac water treatment
- july 16 1998
- vertical stack water source heat pump specifications
- southern illinois university at edwardsville mechanical
Related searches
- leaking heart valves in women
- leaking heart valves symptoms
- trw valves catalog
- air actuated cylinders for lifting
- density of water temperature calculator
- water density vs temperature table
- 3 heart valves leaking
- leaky valves heart
- bad valves in leg veins
- powers valves mixing valve
- tempering valves for water heater
- water temperature mixing valve