RFQ for goods/services - Iraq Business News



Section II: Schedule of Requirements eSourcing reference: RFQ/2020/14947Bidders are required to complete the Comparative Data Tables included in Section II: Schedule of Requirements to demonstrate compliance with UNOPS requirements and inserted below. Bidders are NOT allowed to make any change in the “UNOPS requirements” columns of the Comparative Data Tables. Such changes might disqualify your quotation.Technical specifications for goods – Comparative Data TableLOT 1 - LAB Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Micro centrifuge: Purpose: to separate suspended particles from a liquid or to separate liquids of different densitiesHeavy duty and compatible design 11 ? Yes ? NoInsert details of goods offered, including specifications and brand/model offered if applicableROTATIONAL SPEED To reach a maximum of 13000 rpm or more ,With the ability to choose less rotational speed , for DNA-RNA Extraction the minimum working rpm needed is up to 13000 rpm.Number of tubes (type) 24 * ( 1.5 - 2) mlROTORSVerticalTIMER : Range, min 0 to ≥60 with increment ≤ 1minBRAKING TIME, sec variable time (speed)BRUSHLESSYesNOISE LEVEL, dB <70 LID INTERLOCKYesALERT INDICATORSAudible imbalance, leakage current, lid open, end of run LINE POWER,VAC:220-240VAC , 50-60HzEnvironmental requirementsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidityAutomatic breakingair vent on the coverLED display and a keyboardTachometer to indicate the speed in rpm should be availableInner safety lids that fit over the rotor or tube covers that contain the sample material should be availableGaskets with high quality material for tight sealBowl drainsThe centrifuge should allow calibration by phototachometer manner with lid closedShould use at least an 8 cm rotor radius50 μL sample, and a 75 mm capillary tube, inner protective cover over the rotor assembly2Centrifuge16Spins 3ml-15ml test tubes at 0-6000 rpm Minimum 16 tubesEasy cleanout bowl0 - 6000 RPM Digital programmable control and readout Variable speed and time settings Lid safety lock high g-forces for fast separation Rubber feet to prevent slipping Impact-resistant lid Zero-rpm interlocking lid Wide mouth for easy clean-up Metal rotor and tube shieldsBrushless motor Angled and (swinging )tube holder as alternativeFast breakingProgrammable time and speed Rubber feet to prevent slipping POWER REQUIREMENTS :220v ,50 Hz3Water Purification System4Purpose: is used for producing purified water to cover laboratory needs from distilled water.Configuration: Bench top or wall mountingExternal material: epoxy – polyester powder coated heavy duty material Internal material: Stainless steel or Equivalent The unit consists of Boiler & condenser· Microprocessor controlled· Distilled water capacity (20 lit/hr. )· Storage tank capacity : > 20· Alarms: visual or audial Environmental requirements: the equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidityPOWER REQUIREMENTS: 220-240V, 50-60Hz4Photometric Microplate Reader/Washer (ELISA) 2Application: ELISAs assay , Protein Quantitation , Nucleic acid analysis , Cell Viability, Proliferation, and Cytotoxicity, Kinetic assay , Enzyme assay , evaluate the quantity of antigen or antibodies associated with infectious viral diseases (e.g., HIV, measles, herpes, rubella) , other nonviral applications (e.g., mycoplasma pneumoniae) , other to be specified . A - Photometric micro plate readers: PHOTOMETRIC METHOD: yes , manufacturer dependent on OPTICAL SYSTEM : measurement and reference channels required , multiple channel preferredphotometric accuracy : < 2 %measurement range, ABS : between 0 - 3,0, Or better wavelength range, nm : between 400 – 700,Or betterprecision: ±1%resolution, od : ≤ 0.01light source : Tungsten halogen or xenon flashphotodetector : photomultiplier tube(PMT) preferred and other to be specifiedFILTER TYPE :according to manufacturercompatible micro plates : flat or round or bottom , 96 -well platesIsothermal reading chamber : optionalprogrammable assays : preferredAnalysis: Reading speed, sec/plate : ≤ 15/96-wellComputer interface :yesPrinter : yes (external or built-in)Bar-code reader: OptionalRobotics compatible : yesSelf-calibration :yesQuality control:yes B- Microplate Washers:Configuration: full plate washer or other to be specifiedautomatedwashing parameters : wash volume/time, soak time and otheruser programmable: yesPrograms:user definable: yesnumber of cycles : ≥ 8maximum soak time, sec: ≤ 3.600 compatible plates: well plates other to be specifiedcapacity, number of plates: ≥ 1Wash head : multiple interchangeable wash heads of varying configurationsfluid reservoir : capacity, lwash ≤ 4rinse < 4waste ≤ 4liquid-level sensingYesprecision, % cv≤ 3minimum residual volume ?l / well≤ 5maximum dispense volume ml /well ≤ 3 power requirement( for system)220/240 VAC, 50/60 HZEnvironmental requirements: The equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidity5Portable Glucose Analyzer2APPLICATIONmeasure blood glucose concentration using a reagent strip and a drop of capillary blood from a finger puncture PATIENT TYPEAdult , paediatric, neonateMETHODOLOGYElectrochemical or Reflectance photometry( preferred) and otherREAGENT STRIPSYesSPECIMEN TYPEMinimum sample volume, ?LCapillary whole blood, venous blood, arterial blood, neonatal blood ≥ 0.3 MEASUREMENT RANGE, mg/dL20- 500 or better ALTERNATE-SITE TESTINGForearm, palm, upper-armTEST TIME, secBetween 3 to 60METER CALIBRATION YesLOT-SPECIFIC CALIBRATIONYesREADOUTLCDALERT INDICATORS?High/low levels?OtherOut of measuring range, out of temperature rangeHypoglycemia, hyperglycemia, low battery, under-dose detectionAUTOMATIC SHUTOFFAfter 2 -5 minBATTERYYesLife, no. of tests≥ 1,000Environmental conditionsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidity6Immunoassay Analyzer, Automated1ApplicationIt is used in hospital and clinical laboratories to run automated biochemical tests to detect the presence and concentration of substances in the samples. There are many types of tests that immunoassay analyzers can perform, including testing for cancer markers, diagnosing infectious diseases (viral or bacterial toxin determinations), cardiac analysis, therapeutic drug monitoring, allergy testing, Endocrine hormone testing and protein.CONFIGURATIONBench top and floor typeConnectable to LAS trackYesProcessing modesContinuous, random access ,stat THROUGHPUT, max tests/hr ≥ 100SAMPLE CAPACITY≥ 50SAMPLE TYPESerum, plasma ,urine other should be specifiedSAMPLE SIZE, ?L< 250 Smallest is preferredMETHOD USEDChemiluminescence immunoassay or Electrochemiluminescence (ECL) or fluroscence immunoassay(FIA )TEST MENUAnemia , Diabetes ,Cardiac markers, Endocrine function , Immunoglobulin, Toxoplasma, Thyroid markers ,Viruses, Tumor marker or othersREAGENTS, TYPERefrigerated on boardLiquid, ready-to-use or other typeYesSYSTEM FEATURES: Direct tube samplingLiquid-level sensingClot detectionAuto dilutionAuto calibrationAuto washAll Features should be available DATA MANAGEMENTDisplayLCD , ≥ 15"Results storedYESComputer interfaceYESPrinterYESBar-code readerYESLINE POWER, VAC, Hz220~240 VAC, 50/60 HzBackup power preferred Battery or UPSEnvironmental requirementsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidity7Laboratory Incubator1Purpose: used for growing microorganisms and cells that require oxygen for growth (e.g., bacteriology, virology, cultures) in hospital lab, specialist health center lab. & lab. of Primary health care unit.Configuration: tabletop or Floor TypeInner chamber stainless-steel and out chamber heavy duty materialType door : glass or / & solid doorKey Door lock :yesCapacity , L : 120 – 200 LNumber of Shelves : ≥ 2 , stainless steelTemp is controlled by thermostatTemperature range , °C : 5 to 50 °CTemperature Uniformity +/- 0.5°CAccuracy : ± 1 °CIllumination : internal lightControl system : microprocessor controlled temperature regulation display : digitalAlarms: audio & visual, Temperature, power failureThe heated air circulates through the chamber by fansAll the control switches & Pilot lamps are fitted on the front panelPower requirements: 220-240V, 50-60HzEnvironmental requirements: the equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidity8Light Microscope10Purpose : to provide magnification and resolution of specimens under examinationHeavy duty and compatible designOBSERVATION TUBES Type binocularEyepieces10x,15x, wide field, high-eye pointInterpupillary distance adjustmentmm : ≥( 55 -75), AdjustableNOSEPIECE CONFIGURATIONQuadruple or moreObjectives Magnification(4x,10x,40x,100x) ,other should be specifiedObjectives TypeAchromatic, plan achromatic, plan apochromatic ,or othersTOTAL MAGNIFICATION≥(40x-1000x)CONTRAST METHOD:Brightfield: yesDarkfield: yes Phase: optionalILLUMINATION:Condenser type: Abbe, achromatic &/ or other typeLight source: LED (preferred),halogen, or other STAND:Focusing mechanism: Moving stage, rack and pinionCoarse, fine adjustments: Coaxial, low mounted, ≥ 1? incrementsSTAGE Type:Mechanical or betterTension adjustmentCoaxialStage MotionX-YNumerical aperture0.9 to 1.4Dust coverYesEnvironmental requirementsthe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidityPOWER SUPPLY: 220-240V,50-60Hz9Spectrophotometer: UV VISIBLE SPECTROPHOTOMETER 7Purpose: To determine the absorbance or transmission of characteristic wavelengths of radiant energy by a chemical species in solutionCONFIGURATION:Double beamLAMP TYPE(S)Halogen (Vis), deuterium (UV)WAVELENGTH, nm Range : 190 -1,100 Accuracy:0.3 -1MONOCHROMATORHolographic gratingPATH LENGTH, mm1-100STRAY LIGHTMinimum PHOTODETECTOR Silicon diodeScan speedvariable to at least 300Accuracy±<1%Reproducibility<0.5% @ 0-2 ANoise at 0 A <0.0002 ALinearity ±0.003 A/hrZERO DRIFT <0.0002 A/hrAuto Compensation yesTEST TUBESdifferent volume test tube holderDisplayColor LCD DisplayPRINTER Ink jet, LaserJetUser programmableTemperature controlPC-controlled Windows-based software to provide spectrum processing and storage, complex data calculation routines, Absorbance, factor, concentration, transmittance, scanning, DNA ratio, kinetics, calibration curves, linear and nonlinear, performance validation, multi method/result storage capabilityProtein assay, DNA/RNA purity, concentration by factor method and enzyme kinetics, bacterial density, biocalculationsmultiwavelength, peak picking photometryWavelength scanning, spectral manipulation, time course plot, superimposed plotQuantitative analysis, wavelength scan, time scan, fixed wavelength, baseline correction, absorbance/percent T, peak picking, peak height, peak area, peak width, derivativesMulticell/wavelength measure, peak seek, derivative, autozero, reaction kinetics with plot, histogram plot, gel scanning, curve fit and storage, formula entry, for multi derivativesComputer System interfaceMicrocell holder, test-tube holder10Laboratory Steam Sterilizer (30 L)(Laboratory autoclave)12Type Steam sterilizerTable Top or on Trolley Operating temperatureMax. 134℃ ± 5℃Pressure indicatorHeater: ElectricChamber material: Stainless steelChamber capacity: Approx. 30 LControl: Automatic control from sterilization to dryingNumber of instrument tray: Max. loadable number of offered itemTray RackSafety device: Automatic Door Looking systemPower requirementAC220V, 50Hz, single phase 11Laboratory Water Bath6Applications: sample thawing, bacteriological examinations, warming reagentsHeavy duty and compatible designMaterial: seamless stainless steelExternal: stainless steel, powder coated Temperature range: (10 C above ambient to 100)On off switch and display by thermometer graded for temperatureAccuracy: 0.2?C Temperature preset buttonsCirculation Pump to mix waterMicroprocessor controlledHeater: 1000- 2000 wattsSafety Device for overheating protectionBath Volume: 20 litersWith stainless steel gabled coverThe exterior should remain cool, glass wool insulatorAlarm indicator for overheat limits, low water cutoffPower Requirements 220-240 V, 50/60 Hz12Laboratory Oven 50 L11Temperature range50°C ~ 300°CTemperature control: Thermostatically controlledInside material: Double /Triple walled Construction inner chamber made of Stainless steel with supports on the three sides for two/three adjustable perforated stainless steel shelvesOutside material: - Mild steel sheet painted/powder coated- Insulated stainless steel door with locking and rear zinc-plated steelCapacity> 50 Itr.Safety Alarm- Yes (Audible and visual) - Optional automatically shut down protection circuitAir circulating fanDigital timerPower supply- 220/240 VAC, 50/60 Hz - Over current & over heated protection circuit - Three Pin UK type Plug - Voltage corrector/stabilizer circuit of (Input 160-260 V and output 220-240 V and 50 Hz)Other specification- On/off rocker switch with indicator - Adjustable wire mesh nickel plated trays/aluminum trays- Digital indicator cum controller - The gap between the two walls filled with glass wool insulation - Easy-to-clean interior - Forced air circulation by quiet air turbine/Fan to ensure uniform temperature - Fitted with load indicator and safety thermostat take over indicator lamp. LCD/LED Indicator - Output available for data acquisitionEnvironmental requirementsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidity13Chloride Meter11Easy, intuitive user interface with touch screen and multi-language prompts, which lead the operator through the entire measurement process. Factory calibrated so that manual calibration by lab personnel is not required. It can be equipped with an integrated printer and the results are sent in document-ready format or a PC for data transfer can be connected via USB .Sample volumeApprox. 55 ?l, or lessDuration of measurementApprox. 30 secondsReproducibility± 2 digits (20 ?l) at 100 mmol/lMeasurement display0 - 999 mmol/lMeasurement range10 - 299 mmol/lResolution1 mmol/l over the entire measurement rangeIntegrated stirringMagnetic stir bar PTFE, cylindricalPower source220 V (± 30V), 50Hz, 40 VA, The measurement principle is based on color metric impulse titration as an absolute measurement method. Through automated sample recognition, the measurement proceeds fully automatically after the sample is inserted without the need for manual confirmation by the user.14Dry Chemistry Analyzer (Strip)13Application: used for measuring quantitative results of many parameters from whole blood, plasma or serum within short time.Parameters: Bilirubin, Cholesterol, Creatinine, Glucose, Hemoglobin, Cholesterol, Triglycerides Uric Acid, Urea, Alkaline Phosphates, or otherDetecting method : Reflectance photometry, or otherLight source: LEDLight detector : photodiode or betterSample typewhole blood, plasma or serum. Sample volume≥ 25 μlMeasuring time: less than 5 min.Calibration: AutomaticDisplay: yes , LCD type Memory:≥ 40 results with ( time ,date , ID)Built in PrinterData interfaceNoise level: < 50 dBA UPS YES, power back up for ≥ 10 minEnvironmental conditions: The equipment suitable for work in the climate conditions in Iraq in term of temperature & humidity.POWER REQUIREMENTS: 220-240V, 50-60Hz15Hemoglobin Meter7PURPOSE: For hemoglobin estimationDetector: Silicone photodiode other should be specifiedMeasuring: Transmission/AbsorptionPhotometric accuracy: ± 0.002Cuvette types: should accept different type of cuvettes Display: hemoglobin level in g/dl or g/l, date and timeMeasuring range: ? 0 - 25g/dl Hb, or betterDilution ratio: should be stated Sample volume: minimum sample volume should be stated CalibrationQuality control with control cuvetteSample material : Venus ,arterial or capillaryEnvironmental requirementsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidityOpen system Power supply: 220V,50HzSample compartment: should be prepared for the use with cuvettes, integrated cover for the protection of the sample compartment against ambient light and dirt16Bilirubinometer7Application To measure the concentration of bilirubin in the bloodWhere used Stat labs (hospital) ,amedical clinicsCONFIGURATIONBenchtopMETHOD USEDSpectrophotometry (Dual wave lengths) Patient Neonate, optional (adult , pediatric) Bilirubin measuredTotal, optional dirct SAMPLE TYPESerum or whole blood or plasma SAMPLE VOLUME, ?L≤60 Measurement time, sec ≤5 Calibration Automatic(preferred) Computer interface Optional features (computer interface)USB port Output Units: ?mol /L or mg / dLRange, mg /dL: 0-30 or other rang corering this rangeDisplay, typeLED or LCD power220 VAC ,50/60 HZEnvironmental requirementsThe equipment suitable for working in the climate conditions of Iraq in terms of temperature & humidityLOT 2 – DENTAL Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Dental Unit5Pneumatic dental unit with automatic separator.Gearbox motor or hydraulic for dental chairMinimum height of dental chair (35 ~ 38cm).Maximum height of dental chair (75 ~ 80 cm)Adjustable headrest.Light projector with armDentist tray:Hand piece hanging type.Control panel (with X-ray viewer).3-way syringe.3-module Midwest (4-hole).Ultrasonic scalar.2 turbines (Midwest 4 hole, standard head, stainless steel body, ceramic bearing, push button chuck & autoclavable) one with fiber optic and small head and other turbine standard head without fiber optic.Air motor (forward & reverse control) Contra angle (1:1 direct drive, push button chuck, ball bearing, autoclavable, external water spray, non optic). Assistant tray:Control panel.3-way syringe module.LED curing light.Dry-line suction & saliva ejector & sucker & separatorSpittoon section:Spittoon.Cup fillerDental stool.Assistance stool. Distilled water tank.Air compressor with sound proof (cabinet).Air-suction motor.Foot controller.Input power: 220/240 VAC, 50/60 Hz single phase.External voltage regulator.External disposable filter for waterIntra-Oral Camera Environmental Requirements: The supplier confirms that: The equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.2Digital Dental Radiography3TypeDental X-Ray DigitalApplicationX-ray imaging for teeth and periodontiumX-RAY TUBE ANODE- Type : Stationary - Minimum total filtration, mm Al:≤ 2.5- Heat capacity, HU: ≥ 6,000- Focal spot size, mm: ≤ 0.7X-RAY GENERATOR- Type: High-frequency- kV range: ≥ 60- mA range: Range ≤ 2 to ≤ 8 CONTROL PANELAccording to manufacture (Digital)MOUNTINGStand or wallIMAGING METHODTime to process and display image, sec Bit depth IMAGE SIZES, mmPixel size, ?m- Detector type : CCD or CMOS (complementary metal oxide semiconductors), Wire or wireless, water proof≤ 5≥ 12≥ 30 X 20≥ 15IMAGE PROCESSING FEATURESStandard image manipulation toolsNETWORKINGYesPRINTERLaser COMPUTER SYSTEM- up to date system - Monitor size, type : ≥ 17" LCD- Resolution, pixels : ≥ 1024 x 769- Storage : ≥ 500 GB hard disk drivePOWER REQUIREMENTSSMART UPS 220/240 VAC , 50/60Hz, Three pin plug (G type)≥ 15 Minute for Whole System .Environmental Requirements The supplier confirm that: The equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.3Dental Ultrasonic Scaler2Optic or Non-Optic, headpiece with suitable length of cordLCD display preferableSterilization caseHand piece standWide selection of scaling tips, Priced separatelyFrequency: 27KHz -33KHzOutput power: 3-30WContents: control unit, foot control, bottle of water, and AC power cordPower supply: AC (220 -240)v (50-60)Hz4Dental Unit Autoclave2Application: sterilization of solid instruments, hollow instruments, packed instruments & porous loads. Microprocessor controlled.Self-evaluations on the process of sterilization, automatic failure detection report. Instant vaporizer outside the chamber.Inner Chamber capacity: (18~23) liter, stainless steel.Integrated printer (optional).Safety locking systemLCD displayWater supply system: reservoir (≥3.5 L distilled water and ≥ 5L waste reservoir).Possibility of serial connection to a PC, with cycle data recordingTray holder contains ≥2 tray.Vacuum pump performing two stage (pre & post vacuum).Thermal drying system to ensure sterilizing dental instruments without spotsFull water alarm system.Input power: 220/240 VAC, 50/60 Hz single phase. Accessories: tray extraction handle.Replacing the device filters covered in the warranty.Environmental Requirements :The supplier confirm that: The equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.5Light Cure1Application: Solidify all brands of resin materials of light cure.Heavy duty & compatible design.Light source: LED.Light probe: autoclavable.Adjustable working time.Spectrum range: (400 ~ 500nm).Protection fuse.Acoustic signal: acoustical after 10, 20, 40, 60 sec etc.Input power: 220/240 VAC, 50/60 Hz single phase. Accessories: Eye-protecting cover or optic light guide.Additional light probe. LOT 3 – Imagery Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Mobile X-Ray Unit Digital 5APPLICATIONRadiographic imaging of patients who cannot be transported to radiology departmentSYSTEM TYPE Description Mobile digital radiographic systemIntegrated digital (not upgraded from analog to digital)i.e. (not retrofit)TYPE OF POWER SOURCE BatteryCan be directly powered by AC line ?Yes?YesX-RAY TUBE ANODE Heat capacity, HU Cooling, HU/min Maximum output, kVp Range Increments mAs range Rotating ≥ 200,000≥ 20,000≥ 120 ≥ (40-120) Yes ≥ 300 X-RAY GENERATOR Power rating, kW High-frequency generator?≥ 30ALUMINUM FILTER, mm Yes SID RANGE, cm According to manufacturerINDICATOR METERS Type kVp mAs ?Digital Digital?Digital TUBE MOVEMENT Horizontal, cm Vertical, cm Rotation :Z-axis, °X-axis, ° Applicable for the need of different radiological examination?Yes (specified by the manufacturer)Yes (specified by the manufacturer)?Yes (specified by the manufacturer)Yes (specified by the manufacturer)HANDHELD CONTROL Cord length, m Yes Wire or wireless DIGITAL DETECTOR Type Pixel size Wireless Size, cm Size of built-in display monitor Type of network connectionProcessing (analyses) toolsFilm storage capacity?DR?CSI≤ 160 ?m Yes?≥ 35X43≥ 15" color screen LCD medical monitorDICOM 3.0Specified by the manufacturer ≥ 120 GBPATIENT-CENTERING/ COLLIMATOR LIGHT Yes Power supply Line voltage - Medical Approved power supply board - 220/240 VAC , 50/60 Hz single phase,- Three pin UK type plug2Portable Ultrasound3Scanning?mode?Convex/Linear/Micro-convexDisplay?modes?B,B+B,B+M,M,4BScanning?depth240mmGray?scales?256Cine-loop?≥ 500?frames?Image?permanent?storage?≥ 64?framesImage?conversionup/down,?left/rightLocal?zoom2?times?both?in?real-time?and?frozenMeasurementDistance,?circumference,?area, volume,?,?heart?rateOB?measurementBPD,?CRL,?FL,?AD,?HC,AC,?EDD,?GA,?FWProbe?connector?≥ 3Monitor≥ 15?inch?Wide?application?Abdominal,?OB/GYN,?urology, Doppler, cardiology,?small?parts?examination,?…etcProbesStandard?configuration approx 2-5 MHz convex probe ,transvaginal 4-8 MHz Optional?configuration?optional probe ( 5-10MHz Linear,Probe)Power Supply- 220/240 VAC, 50/60 Hz - Over current & over heated protection circuit - Three Pin G type Plug- Voltage corrector/stabilizer circuit of (Input 160-260 V and output 220-240 V and 50 Hz)-UPS (Rechargeable battery) of suitable rating with voltage regulation and spike protection for ≥ 15 minutes back upLOT 4 - MEDItem NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Otoscope5Offering clear, live and still images of the ear canal and tympanic membraneChrome Plate handleStandard, heavy duty rechargeable batteries.Reusable and disposables specula different sizesSoft pouch or hard Plastic caseRheostat for adjustment of illuminationFiber optic for cool, obstruction free light transmissionMagnification z(2.5-≥3) X.Bulb: LED typeEnvironmental requirements: the equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity2Fetal Heart Detector, Ultrasonic8TYPE/CONFIGURATIONHandheldAPPLICATIONSDetect fetal heartbeat measure FHRFHR DISPLAY RANGE, bpm≤ 60 - ≥199 PROBEFrequency, MHzOutput, mW/cm?≥ 12 to 3< 20OUTPUTSSpeakerHeadphonesYESOptionalDisplayDisplay variablesLCD , LED or better FHRCONTROLSVolume, power on/offPOWER REQUIREMENTSBattery, typeOperating time, hrLow-battery indicatorRechargeable preferred or Alkaline or dry cell ≥ 2YESAccessories Ac adapter for rechargeable battery CaseGel (start up qty.)Environmental requirements:The supplier should be confirmed that: The Equipment is suitable for work in climate conditions of Iraq in terms of temperature and humidity.3General Surgical Operating Table2ApplicationGeneral TABLE POSITIONS(Degrees from horizontal)TrendelenburgReverse TrendelenburgLateral tilt≥25≥25≥18Vertical range, cm (in)Height adjustment with mattress(750-980) mmTABLE SECTIONSHead section (removable), Back section, seat section, Split Leg section (Removable)Back section(+85 Degree, -45 Degree)Foot/leg section(+20 to -90 )Head sectionVariableACCESSORY SIDERAILYesPERINEAL CUTOUTYesMAXIMUM PATIENT CAPACITY, kg (lb) Max. dynamic load capacity ≥ 200CONTROLSTypeManual overrideWired remote control and Foot controlElectric or Electrohydraulic or Electromechanical YesRadiolucent tabletopC-arm accessibleYesYesACCESSORIES2 arm board 2D Left & Right with attachment clamp, pair of shoulder support with attachment clamp , Body straps, Anesthesia screenDIMENSIONS, H x W x L, cm (in)Fully extended(width , Length 4 section) W 500mm or less , L 2000mm or moreColumn housingStainless steelCaster lockYes POWER REQUIREMENTSBatteryPower input 220-240VAC, 50Hz.YES Environmental requirement The supplier should be confirmed that: The Equipment is suitable for work in climate conditions of Iraq in terms of temperature and humidity.4Infant Incubator11Application Used for providing a closed controlled environmental that warms an infant by circulating heated air over the infant skin.Operating modesAir temperature control.Skin temperature control (servo controlled)MOBILEYes, castors( size≥ 10 cm) with breaksTEMPERATURE CONTROL RANGE, °C:Air (Increment: 0.1°)Skin (Increment: 0.1°)Min:(20-25°) Max: (37- 39°)°Min:(33-35)° Max:(37-38)°TEMPERATURE DISPLAY (air & skin)Digital or LCD(LED) ALARMSHigh air tempLow air tempHigh skin tempLow skin tempFan failureSensor failurePower failureBACKUP THERMOSTATYESHEATER POWER INDICATORYESHAND PORTS≥4TUBING PORTS≥5O2 SOURCEInlet PortsControllersAlarm ≥1servo controller preferred ( 21%-60%)YESSupplemental HumidityAdjustable Water tank for humidity control YESYES (Digital controller)Shall be removable and sterilizeableInternal Noise, dB≤ 60Double WallYESMattress Water proof Trendelenburg + 12 degreeAccessories IV pole.Drawersin-bed scaleintegrated x-ray trayDisposable temperature sensors (25 pcs)Options:Battery up for alarms & Trends to 1 hr.Variable-height stand.Environmental requirementsThe equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.Disinfection:According to manufacturer The manufacturer should specify the types of disinfectant suitable to the incubator.Should be not affect the incubator coating & environment. 5Infant Scale6Material & Design1)Ergonomic tray provides secure support with a robust plastic tray for easy and hygienic cleaning 2)Secure and non-slip positioning with rubber feetPower supply- 220/240 VAC, 50/60 Hz - Over current protection circuit - Three Pin UK type Plug - Voltage corrector/stabilizer circuit of (Input 160-260 V and output 220-240 V and 50 Hz) - Can work using ( alkaline or chargeable) battery(s) - Battery Life > 200 hours for not chargeable type of batteriesOther specification1) simple and convenient 1-key operation 2) Automatic Data Hold Function Batteries includedWeighing range>10KgWeighing accuracy0.01 KgDisplayDigitaldimensions(W x D x H) mmTo be mentioned 6Infusion Pump2ApplicationAccurately deliver liquids through intravenous (IV) or epidural routes for therapeutic and/or diagnostic purposesCONFIGURATION Number of channels ?≥1?DISPLAY Data displayed ?Alarms, drug name, pumping status, volume infused, VTBPUMP CAPABILITIES Flow range, mL/hr Increments, mL KVO rate, mL/hr Accuracy, % VTBI Selector, mL Automatic piggybacking Fluid resistant Front-panel lockout ?≤ 1- ≥999 0.1-100 mL/hr 1-≥3±5 Yes(1-9,999) Yes( if number of channels > 1).Yes YesType of systemOPEN SYSTEM, the pump must be able to operate using standard (non-dedicated) IV set from multiple manufacturersIV SET Free-flow protection Air-trapping capabilityNeedleless IV connection ??YesYesYes ALARMS & INDICATORS Occlusion upstream Occlusion downstream Detection mechanism Pressure, psi Real-time display Air in line System malfunction Set loaded improperlyDoor open Infusion complete Low battery Depleted battery Clinical advisory messages?Yes Yes Yes?≤15 YesYes Yes YesYes Yes Yes Yes YesAUDIBLE ALARM Volume control Momentary silence ?YesYes??DOSE ERROR REDUCTION SYSTEM (smart technology)Defaults to DERS on startupLibrary sizeNo. of care areasNo. of drug entities per care areaDATA PORTYesYes≥ 100≥10≥100YesEVENT LOG Events stored Yes , by InterfaceKey presses, program settings, alarms, volume infused, dose limit warnings*Power supply Line voltage BatteryLife, hr @ flow of 100 mL/hrRecharge time, hrMedical Approved power supply board 220/240VAC,50/60Hz, Three pin (G type) plug YES≥5<87Mobile Surgical Light4Application Surgical lights illuminate the surgical site for optimal visualization of small, low-contrast objects at varying depths in incisions and body cavitiesLIGHT SOURCE, TYPE Number of light heads Number of LED s Volts Service Life, hr LED Single Should be specified According to LED type ≥ 30,000 COLOR TEMPERATURE, K Adjustable 4,000-5,000 YesCOLOR RENDERING INDEX R9 value ≥ 94≥ 90 (higher preferred)FIELD SIZE, cm Diameter Depth≥16 ≥ 80 FOCAL LENGTH, cm ≥ 65 ILLUMINATION LEVEL, maximum lux at 1 m ≥ 100,000 MOUNTING mobile floor standCONTROLS Dimmer Focus Field size On sterile handle ?YesAdjustableAdjustableYes?2 for each unitREFLECTOR MATERIAL According to manufacturer Light head diameter, cm To be mentioned Power supply- 220/240 VAC, 50/60 Hz- Three pin G type plug- ≥ 1 hours back up battery(s) with automatic charging and change over circuits 8Phototherapy, Free Stand 8 TYPEFreestandingANGLE ADJUST, °AdjustableIRRADIANCE @ 420 to 480 nm, ?W/cm?/nm400-550 (any value between) FAULT PROTECTIONFuse or breakerLIGHT SOURCES LEDType: LED Number needed: To be specified by manufacturerExpected life, hr≥ 8,000HOUR METERYesPROCEDURE TIMERPROCEDURE TIMERHeight adjustYes ≥ (107- 150) or wider range RadiometerOptional Others The unit should be mobile with swivel castors fixed to a base to be accommodated beneath incubator /cot.Accessories: glasses for eye protection & UV filter cover.Power & Environmental Requirements Input power: 220/240 VAC, 50 Hz single phase, minimum length of the wire (3m). Three Pin G type Plug, Voltage stabilizing and over current protection circuit.The supplier should be confirmed that: The Equipment is suitable for work in climate9Sphygmomanometer49Stationary blood pressure measurement device..The precision pressure gauge is recessed in a premium, impact-resistant, is easy to clean the ABS housing.The easy to use spiral hose, inflation bulb with precision adjustable threaded discharge valve and optimized readability on the oversize scale through anti-glare glass guarantee ultimate functionality.10StethoscopeAcoustic sensitivity and durability.Traditional bell. 44The device has conventional combination of two-sided chest piece. One side of the device has tunable diaphragm and on the other side it hasThe headset is anatomically designed. black tube colors.11Surgical Suction Unit14Application: suctioning to remove blood and irrigating fluids that accumulate in the operative field and obstruct the surgeon's view, used in OR, Wards , ICU, and others.CONFIGURATION: Mobile on cart with castorsPUMP TYPE: Piston, or Diaphragm, Others to be specifiedNumber of pumps: ≥ 1VACUUM LIMIT, mm Hg, (cmH2O): ≥ 500 , (679.75)Free airflow, L/min ≥25VACUUM CONTROLYESCOLLECTION CANISTER(S)Reusable &DisposableNumber≥2Capacity limit line, mL≥2000Overflow protectionYESFILTER TYPEBacterial, hydrophobicSTANDARD ACCESSORIES(Included in Warranty) Collection bottle.Filters.Cart.Optional **footswitchElectrical Ratings- Power Supply -220/240VAC- Rated Frequency 50/60HzEnvironmentalThe supplier should be confirmed that: The Equipment is suitable for work in climate conditions of Iraq in terms of temperature and humidity.12Ophthalmoscope4ApplicationDiagnosis of eyeComponentInterchangeable handleOphthalmoscope headBattery (dry cell or rechargeable )Power requirementAc Adapter be 220-240VAC, 50Hz.For rechargeable battery Corrective power rangeFrom- 20 to +20 or wider rangeAperture: 5 apertures or moreFilterred-free , others to be specified Light source LEDcolor rendering index > 95Number of Lenses≥ 18Environmental requirements:The supplier should be confirmed that: The Equipment is suitable for work in climate conditions of Iraq in terms of temperature and humidity.13Digital Scale11ElectronicLCD displaycolumn typewith BMI calculationkg (496.04 lb) \0.1 kg (0.22 lb) or morewaist-level digital physician scales LCD display with Body Mass Index calculation powered by 6 AA batteries or equivalent or optional AC adapter (neither included). Height rod available.500 lb x 0.2 lb / 225 kg x 0.1 kg capacity. or more14Oxygen Cylinder5The Steel "M" medical oxygen cylinder back up units or to use to supply oxygen filling system. The Steel "M" cylinder can supply up to 3540 liters of oxygen. The cylinder comes standard with a CGA540 valve and can be conveniently stored using our STANDM60T01-A adjustable cylinder stand.15Surgical Curettage Set3All should be stainless steel – each set should contain the followings: DRESSING FORCEPS, 25 CM1pc.setTOWEL FORCEPS, BACKHAUS, SHARP, 9 CM4pcs.setSPONGE FORCEPS, BOZEMANN, S-SHAPE, 26 CM1pc.setSPONGE FORCEPS, RAMPLEY, STR., 24.5 CM2pcs.setCATHETER F. WOMEN, CVD., 14 CH, 15 CM1pc.setVAGINAL SPECULUM, SIMS, 65X25/70X30 MM1pc.setVAGINAL SPECULUM, SIMS, 70X30/70X35 MM1pc.setVAGINAL SPECULUM, AUVARD, 75X43 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 3/4 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 5/6 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 7/8 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 9/10 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 11/12 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 13/14 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 15/16 MM1pc.setUTERINE DILATOR, HEGAR, DOUBLE, 17/18 MM1pc.setUTERINE PROBE, SIMS, MALLEABLE, 33 CM1pc.setTENAC. FCPS., SCHROEDER, 1X1 T., 25.5 CM2pcs.setUTER. CURETTE, 6 MM, SH., RIG., 30.5 CM1pc.setUTER. CURETTE, 11 MM, SH., RIG., 31 CM1pc.setUTER. CURETTE, 14 MM, SH., RIG., 31.5 CM1pc.setUTER. CURETTE, 6 MM, BL., RIG., 30.5 CM1pc.setUTER. CURETTE, 11 MM, BL., RIG., 31 CM1pc.setUTER. CURETTE, 14 MM, BL., RIG., 31 CM1pc.setOVUM FORCEPS, WINTER, CVD., N. 2, 28 CM1pc.setTissue forceps2pcs.setRetractor, small1pc.setRetractor, medium1pc.setScalp handler, 3, 7 and 3L one each1setsetSterilizing Case1pc.set16Lead Barrier 3mm Lead 1x2 M9Small Window X-ray Mobile BarrierDimensions (80*190CM).(W*L) ,Or better Thickness of 2mm or better Powder coated steel frames, precision TIG welded for years of trouble-free service completely enclosing the leaded glass panel for increased durability and safetyLead glass or lead acrylic options available3 mm lead equivalent opaque base covered in “Sintra” plastic for easy cleaning and durabilityModular parts can be easily replaced, including the glass if needed.Stainless steel or coated metal finish. Swivel casters.Window OptionsLead: 2 mm Pb equivalencyAcrylic: .50 mm Pb equivalencyLOT 5 – MEDICAL Furniture Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Bedside Cabinet5With metallic drawer and cupboard.Upper board made of plywood with antis hock edges in ABS plastic.Feet with non-slip ends.Made of epoxy coated sheet steelDIMENSIONSApprox. 390 x 480 x 880 mm2Examination Couch With Steps23Backrest adjustable by self-locking system with bilateral controlThick foam with high quality vinyl fabric upholstery, at least 65 mm thickPaper roll holder with one rollWelded tube reinforcementTips of pads adjustableTubular stainless steel frame ? 30 mm or better Non slippery, two level stepladder made up of stainless steel Or coated metal with a tubular frameApproximate dimensions (L x W): 1800 x 600 mm3Drug Trolley4Transport, multi-function2 detachable 2 pressed trays or more, with dimensions of minimum 600 x 400 x 60 mm.Two drawers or moreHandle to facilitate movements?80 mm casters or more, with bumpers (two with brakes).Slide removable basketMade of stainless steel Minimum Dimensions: 950 x 420 x 830 mm4Stainless Steel Paravane22Folding 3-section screen panel for hospital useConstructed of stainless steelWashable curtains (White color fabric)Each screen panel folds independentlyWith rolling wheels Dimensions: Hight: 180 cm approx.Width (for each section): 60 cm approx.Total width: 180 cm approx5Delivery Bed2Application: used for birthing cases. Table’s upper flat surface has ≥3 sections.Frame: powder coated or stainless steel bed frame.Mattress: dynamic surfaces (multi-layer plywood, foam & leather).Height, back rest, Trendelenburg, table’s head & foot parts are controlled by controller buttons within the side rail.Type: electro-hydraulic.Dimensions:L×W: Pease specify H: (≥60 cm) ,(+.-)10cm4 Castors(size ≥12.5 cm) with 2 breaks.Patient weight: (≥175kg).Drain pan: yes.Number of motors: (≥2).Bumpers: yes.Input power: 220/240 VAC, 50/60 Hz single phase.Movements:Adjustable backrest.Adjustable leg section.Adjustable Trendelenburg & reverse TrendelenburgAdjustable height.Adjustable foot section.Standard accessoriesLeg rest (knee crutches).Foot rest.Side rails.Lifting pole.IV pole (2 or 4 hooks).Labour / squatting bar.Monitor tray.Arm rest.Battery backup.Optional accessories:Removable headboardEnvironmental requirements: the equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.6Phlebotomy Chair4Functions movement: up/down, back section turn, and leg section turn.castors :NOMaterial: high quality (strength).Easy to clean seamless cushions, Antimicrobial fabricAllows right or left-sided proceduresChair dimension : To be mentioned Arm board swing out : 0~≥ 45oArm board height adjustment : ≥ 70mmArm board slide ≥80 mmArm board dimension : To be mentioned Capacity(loading):≥140 kg7IV Pole11The minimum features of the intravenous pole shall be:Material of IV pole: stainless steel (grade: 304)Number of IV hooks: 4Minimum payload capacity of each hook: 2 kgMaterial of hooks: stainless steel (grade: 304)Height: shall be with adjustable rod height (approx.. 120 to 200 cm)IV pole base: with 5 anti-static swivelling castorsIV pole base design: the base shall be with low center of gravity to ensure stability8Wheelchair5Aluminium footrestFolding manual wheelchair.Varnished steel. Max load at least 120 Kg.Manual wheelchair in varnished steel with removable rear wheels quick-release 12" PU.Removable footrests.Leather upholstery and flip-open armrests. Wheels for narrow passages. Head rest with stands 9Stretcher Stainless Steel4Pneumatic back raiseHi-lo adjustment by torque release handleAluminium or steel frameVinyl leather mattressRemovable stretcher aluminium plate platformOxygen cylinder holderFold-down safety side railsIV PoleDimensions : 550W x 1905L x 666~1016mm H150mm caster with total locking system10Dressing Trolley28Transport, multi-functionTwo detachable 2 pressed trays with dimensions of minimum 600 x 400 x 60 mm. ≥ Two drawers. Handle to facilitate movements. ≥ ?80 mm casters, with bumpers (two with brakes). Slide removable basket Made of stainless steel Minimum Dimensions:800 x 420 x 830 mm LOT 6 – MONITORING Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1ECG21MEDICAL APPLICATIONDetect the electrical signals associated with cardiac activity and produce an ECG, a graphic record of the voltage versus time to diagnose and assist in treating some types of heart disease and arrhythmias. PATIENT TYPEAdult, paediatricType Open System CONFIGURATIONCARTPortableYes with ECG cable holderLEADSSwitchingSensitivity, mm/mVCalibration signalFrequency range, HzDiagnosticFilteredCMRR @ 60 Hz, dBLeads-off indicator?Automatic, optional manual ≥ 3 values ex. (5, 10, 20)Automatic, optional manual?Range ≥ (0.05-150)HzYes ≥ 100YesRECORDERNo. of channelsRecordingmethodPrinterPaper sizeLead markerTiming markerEvent markerChart speed, mm/secChannels acquired simultaneouslyChannels printed simultaneously12 leadsThermal arrayIntegratedAccording to manufacturer YesYesAccording to manufacturer Minimum ≤ 25, Maximum ≥ 50(steps should specified by the manufacturer) ≥ 12≥ 12NO. WAVEFORMS DISPLAYED≥ 12NO. WAVEFORMS STOREDSpecified by the manufacturerECG TRANSMISSION TO ECG DATA MANAGEMENT SYSTEMYesPROGRAMSAdult resting ECG, other specified by the manufacturer USER INTERFACEKeyboard or TouchscreenSTORAGENormal, no. ECGs?≥ 50PATIENT DATAName, sex, age, others (specified by the manufacturer)MEASUREMENTS Arrhythmia IDOther printoutsYes HR, PR,QT and others YesOptional (Specified by the manufacturer)4.8.1ST segment analysisYes INTERPRETATIONAnalyzed waveformAnalysis window (sec)YesSpecified by the manufacturer≥10 PREVIEW SCREENYesDISPLAY TYPE≥ 7 in. LCD or TFT or betterVISUAL INDICATORSSpecified by the manufacturerDEFIBRILLATOR OVERLOAD PROTECTIONYesReusable vElectrodes for startupsAt least 5 sets BATTERY OPERATIONBattery type (No.)According to manufacturer (device should be able to work on direct AC line)Specified by the manufacturerPower supply Line voltage Medical Approved power supply board - 220/240 VAC , 50/60 Hz single phase, Three pin G type plug2Defibrillator- Monitor With AED4Acuity AreaOR. , ICU. PICU , CCU , wardsEnergy selection -External: (≤ 2 -≥200)J BiphasicPaediatric / Neonatal: (2-20) J.-Internal: MAX. 50 JPaddles (adult + paediatric)ExternalInternalPaddle controlsCharge, discharge, Others to be specifiedSynchronizerYes AED modeYes with disposable pads start up qty for at least 100 patientsCPRmeasurement and feedbackECG MONITOR- Color LCD or better- Screen, (in): ≥ 6- Sweep speed, mm/sec: ≤ 50 selectable.- Lead configuration: ≥ 3. Through-the-paddles monitoring- HR display- HR alarms- Lead-fault indicatorReusable ElectrodesDisposable electrodesAdult and paediatric , start-up Qty (should be specified)start-up Qty for at least 200 patientSelf-testYesExternal pacemaker- Pacing mode: demand and fixed.- Pacing rate (ppm): ≤(40-210)ECG RecorderAnnotation- Thermal printer.Time, date, lead, gain, heart rate, operating mode.Other Monitored Parameters- SpO2- NIBPCartYesPower220-240VAC, 50Hz,G type Plug.Battery PowerOperating time, hrFull Recharge time, hr.Rechargeable≥ 2 continuous ECG monitoring or ≥ 100 discharges.≤ 4>protectionAgainst harmful ingress of water:IP24, IP21Against electrical shock: Type Class IequipmentEnvironmental requirements:The equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.Acuity AreaOR. , ICU. PICU , CCU , wardsEnergy selection -External: (≤ 2 -≥200)J BiphasicPaediatric / Neonatal: (2-20) J.-Internal: MAX. 50 JLOT 7 – VENT Equ. Item NoUNOPS minimum technical requirementsQty.Is quotation compliant? Bidder to completeDetails of goods offered. Bidder to complete1Anaesthesia Machine3MEDICAL APPLICATIONDispense a mixture of gases and vapors and vary the proportions to control a patient's level of consciousness and/or analgesia during surgical procedure. PATIENT TYPEAdult, pediatricPipeline gas inlet 3 (N2O, O2, air), including hoses with probes to outlets, probe to be compatible with the type of outlets in the hospitalGas cylinder yokes(O2, N2O, air), including hoses to connect to backup cylinders with regulatorsVaporizers agentsNumberInterlock Agent level indicatorIsoflurane, sevoflurane≥ 2Yes Yes O2-fail safeYes Hypoxic mixture fail-safeYes Automatic ventilatorBellows size or otherVentilation modesTidal volume (cc)Minute volume (L/min)Frequency (Bpm)Inspiratory flow (L/min)Pressure limit (cm H2O)PEEP (cm H2O)Yes -Adult, pediatric-Manual / spontaneous, VCV, PCV, SIMV or pressure support & pressure control volume guaranted-Minimum (≤20) and for neonatal option (≤5 by pressure control or volume control), Maximum (≥1400)-≤ (0-100)-≤ (2-100)-≤ (0-200)-≤ 125 (adjustable)-≤ (0-50)System checksYes Scavenging system PassiveBreathing circuitStartup kit with CO2 absorption canister (soda lime or barium lime)Monitors Air way pressureWhere measured High pressure alarmSubatmospheric pressure alarmContinuing pressure alarmLow pressure/apnea Expiratory volume/flowType of sensorWhere measured Apnea alarmReverse-flow alarmHigh/low minute volumeHigh/low flowCapnograph O2 concentrationType of sensorResponse time (sec)CO2 concentrationApnea alarmYes Inspiratory limb or expiratory limbYesYes Yes Yes Yes According to manufacture Expiratory and/or inspiratory limbYes Yes Yes Yes Yes Yes According to manufacture≤ 35Yes Yes N2O Agent monitorsType of agentAuto IDAgent concentration alarmYes Yes Isoflurane, sevofluraneYesYes Display NOType size- ≥1- color LCD or better≥12?User interfaceAccording to manufactureEvent logTrack alarmsTime and date stampedYes Yes Yes Accessories-Reusable patient circuits for adult, pediatric and neonates-Reusable anaesthesia masks for adult, pediatric and neonates -Reusable re-breathing bags for adult, pediatric and neonates -Reusable flow and oxygen sensor-Disposable microbial filters with heat & moisture exchangers (HME) for adult, pediatric and neonates-Test lungs -Soda Lime-Articulating patient circuit holder/armPower supply Input powerBack up battery220/240VAC,50/60Hz, Three pin (G type) plug, voltage stabilizing and over current protection circuitYes, ≥ 0.5 (hr)2CPAP , Neonate5Application- Deliver air or a mixture of air and oxygen (O2) through a nasal mask or nasal tubing to the patient’s airways- Non – invasiveMODESCPAP &Optional Bi-level CPAP (other modes should be specified)MASKConfigurationMaterialNo.Size Nasal prongs , nasal mask (neonatal size)Any except (PVC), latex freeStart-up kit (Qty: should be specified )neonateCONTROLSInspiratoryPressure, cm H2OExpiratoryPressure, cm H2ORate, bpmTrigger sensitivityMin ≤ 6MAX. ≤40 according to operating modes. MIN ≤ 4 MAX≤ 25≥ (1-30) optional according to operation modeAutomatic or adjustableMONITORED PARAMETERSRespiratory rateFlow rangeLeakPEEP / or PIPOtherOptional according to available modesYesYesYesShould be specifiedPC COMPATIBLEYesSoftwareYesEQUIPMENT ALARMS:Power failureFaultMask alarm or pressureLow batteryPreferredYesYes YesDISPLAY TYPELED or LCD or betterNOISE LEVEL, dBA≤ 45Air/O2 supplyYESHumidifierYESCompressor or turbineYESOxygen analyzerYESAIR FILTERYes (changing filter the responsibility of the supplier during the warranty and maintenance period).TUBING Length, cm (in)MaterialYes ( start-up Qty should be specified )≥ 180Any except (PVC)ACCESSORIESComplete manufacturer line of accessories (Should be specified )Bonnets for single-use ( start-up qty should be specified )BATTERYRechargeableOperating time, hrChargerYes≥ 1 hrYesPower supply- Medical approved power supply board- 220/240 VAC, 50/60 Hz, Three pin G type plugEnvironmental requirements Manufacturer confirms that the equipment suitable for work in the climate conditions in Iraq in terms of temperature & humidity.3Nebulizer20Method of Nebulization?Ultrasonic VibrationUltrasonic frequency1.7MHz+-10%Maximum pressure?200kPaFrequency≥ 2.5MHZ Oscillation rateContinuous working time≥ 4 hours Operating Humidity & Temperature Range?10°C- 40°C | 30%-95%RHStorage Humidity & Temperature Range?0°C - 70°C | 30%-95%RHParticle Size?diameter0.5-5.5 (MMAD-3.8 Microns) Max nebulizing≥ 4ml/minDroplet diameter1~5 μmCapacity of cupsSmall cup ≥ 100mlLarge cup ≥350 mlMechanical timingStep less adjustable 0-60minWater tank≥ 300 mL observed by water level lineAccessoriesportable battery pack, pediatric mask, adult mask, AC adapter, nozzle, air filter and mouthpiece, closed water chamber system, timer and air flow adjuster, 9-12 VDC DC adapter, carrying bagPower supply - 200/240 VAC 50/60 Hz , 9-12VDC- Typical solid state, over – current circuit protectionBatteryRechargeable ≥ 3 hours backup battery Other specificationSilent operation(totally noiseless), compact design and one hand use makesTreatment times are 50% less than a motor driven nebulizerSafe – Low battery indicatorOverheat protectionDistilled water or drinking water can be used4O2 Regulator, Low Pressure10Application:For use on MEDICAL oxygen cylindersHave a 20-micron, sintered-bronze inlet filter.All flows are tested to accuracy within +/- 15 percent tolerances.Brass components in high-pressure areas and relief valve zones.Standard Liter Flow Options: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, and 15Inlet Pressure: approx. (200-3000) PSIGeneral requirements:All medical equipment shall be 100% new and from current manufacturer production lines. It must NOT be refurbished. It must NOT be discontinued at the time of signing the Contract.All medical equipment must be CE, FDA, and/or TUV certified (or equivalent). Quality assurance test certificates shall be submitted to UNOPS, whenever requested.Full functionalityThe offered medical equipment shall include a full set of compatible parts, components, accessories, software, hardware, start-up consumables and howsoever required to put the medical equipment into fully operational condition to the satisfaction of UNOPS.Any parts, components, adapters, software, hardware etc, that are NOT mentioned in the technical requirements or technical offer, but required to put the equipment into fully operational condition shall be deemed part of the awarded medical equipment and must be provided by the Supplier at no additional cost.All electrically operated equipment must be designed to run on the standard AC power (voltages and frequencies) in Iraq. Equipment operated at 110V (with and without transformers) shall NOT be acceptable.Pre-installation requirements:All medical equipment, or its component, that will be permanently built-in or mounted on floor, wall or ceiling shall include all needed fixtures, supports, arms, mounting parts/interfaces, finishing seals, and howsoever required to mount the unit and complete the installation.?All ceiling suspended equipment must include the design, supply and installation of the interface steel structure between the false-ceiling and concrete ceiling.Packaging, Shipping, Storage and Delivery:The equipment package shall be well labeled, with instructions for handling, lifting, etc. The equipment package shall be labeled with the Supplier name, Manufacturer, model number, and date of manufacture.The equipment shall be packaged in a way to withstand handling, loading, unloading, temperature, humidity and other extremes likely to be encountered during shipping and transport to Iraq.?The Supplier shall be responsible for shipping and delivery of the equipment within the time frame stipulated in the Invitation to Bid.The supplier is responsible for delivering the medical equipment to the specific locations as mentioned in the Invitation To Bid. The Supplier is responsible for loading, unloading, rigging and inside delivery of the medical equipment to its final destination room inside the building.?Installation?The Supplier shall assemble, mount, install, configure, calibrate, test and commission the medical equipment as per published manufacturer’s instructions, applicable international & local standards, to the satisfaction of UNOPS.Any materials or work found to be defective, not in conformity to the requirements herein, or damaged shall be removed immediately, and new materials or work substituted without delay.Installation inspectionInstallation Inspection shall demonstrate proper and safe installation and operation of the medical equipment as per the published manufacturer’s specifications, applicable standards, and to the satisfaction of UNOPS. Whenever deemed necessary by UNOPS, the Supplier shall provide calibrated testing equipment, analyzers etc to verify proper function/performance of the equipment as per the published manufacturer’s specifications.?The Supplier shall provide 2 original user manuals and 2 original technical service manuals. Soft copy of user and service manuals (on CD) shall be also provided. Technical service manuals shall include spare parts lists, electronic circuits schematic diagrams, and detailed troubleshooting guides (where applicable).Warranty and Maintenance:The Supplier shall provide full warranty, for the period stipulated in the Invitation to Bid. The warranty shall cover free maintenance/labor and free spare parts throughout the warranty period.All maintenance and services must be provided by qualified and certified staff.?The Supplier shall conduct scheduled Preventive Maintenance (PM) according to the manufacturer recommendations and applicable standards.?The Supplier shall fix malfunctioning equipment within a maximum of 4 days from the date of notification.?The Supplier shall replace or repair all defective equipment and software, and shall correct any defects -without charges for parts or labor- both during and after regular working hours, during the warranty period.The Supplier shall provide -without charges for parts or labor- an equivalent replacement of any defective part that cannot be repaired or corrected to the satisfaction of UNOPS/MOH during the warranty period.The Supplier must guarantee an uptime of 95% calculated yearly during warranty, unless otherwise requested by MOH to follow current protocols applied by MOH.All warranties and rights shall be transferrable from UNOPS to the Ministry Of Health (MOH) upon transfer of ownership, the date of which shall be agreed between UNOPS and the MOH.Delivery requirements –– Comparative Data TableUNOPS RequirementsIs quotation compliant? Bidder to completeDetails Bidder to completeDelivery timeBidder shall deliver the goods 4 - 6 months after Contract signature.? Yes ? NoInsert details Delivery place and Incoterms rulesDAP Incoterms rules as per Incoterms 2020.as per Annex I distribution plan ? Yes ? NoInsert details Consignee detailsTBC? Yes ? NoInsert details UNOPS Right to vary requirementsAt the time the Contract is awarded, UNOPS reserves the right to vary the quantity of the goods and associated services?specified above, provided this does not exceed +/- 35%, without any change in the unit prices or other terms and conditions of the RFQ.? Yes ? NoInsert details 00ax: +45 45 33 75 0100ax: +45 45 33 75 01 ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download