Untitled Document [www22.verizon.com]



Service and Product Enhancement Code (SPEC)

Job Aid

Purpose

The purpose of this job aid is to assist with the population of the Service and Product Enhancement Code (SPEC) field on the Access Service Request (ASR).

Definition

The SPEC field identifies a specific product or service offering. Verizon uses this code to validate entries on the ASR based on criteria for the product or service being requested.

TABLE OF CONTENTS

TABLE OF CONTENTS 3

WEST 5

APPLICABLE STATES 5

WEST SPEC CODES 6

FRAME RELAY 6

ASYNCHRONOUS TRANSFER MODE (ATM) 6

IP VPN 6

TRANSPARENT LAN SERVICE (TLS) 7

DEDICATED TRANSIT SERVICE (DTS) 7

METROLAN TRANSPORT FOR DS1 SERVICES 7

FIBERCONNECT 8

NEAR OUT OF FRANCHISE (NOOF) 8

BANDED OPTICAL TRANSPORT 10

DEDICATED SONET RING (DSR) 11

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS) 12

INTELLILIGHT ENTRANCE FACILITY (IEF) 13

ETHERNET PACKET RING SERVICE (EPRS) 13

VERIZON OPTICAL NETWORKING (VZON) 14

UNBUNDLED NETWORK ELEMENTS (UNE) 14

SIGNALING SYSTEM 7 (SS7) 14

SWITCHED SERVICES 14

NORTH 15

APPLICABLE STATES 15

NORTH SPEC CODES 16

FRAME RELAY 16

ASYNCHRONOUS TRANSFER MODE (ATM) 16

ASYNCHRONOUS TRANSFER MODE (ATM IMA) 16

TRANSPARENT LAN SERVICE (TLS) 16

ENTERPRISE 17

FMS 17

LES 17

VZON CONNECTED TO ACCESS AGGREGATION PORT 17

VZON CONNECTED TO A DSR 18

VZON CONNECTED TO IEF STUB HUB OR MID SPAN MEET 18

BANDWIDTH ON DEMAND (BOD) 18

DEDICATED SONET RING (DSR) 19

DEDICATED SONET RING & INTELLILIGHT OPTICAL TRANSPORT SERVICE 19

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS) 20

INTELLILIGHT ENTRANCE FACILITY (IEF) 21

INTELLILIGHT BROADBAND TRANSPORT (IBT) 22

VERIZON INTEGRATED OPTICAL SERVICES (VIOS) 22

VERIZON OPTICAL NETWORK (VZON) 22

UNBUNDLED NETWORK ELEMENTS (UNE) 23

SOUTH 24

APPLICABLE STATES 24

SOUTH SPEC CODES 25

FRAME RELAY 25

ASYNCHRONOUS TRANSFER MODE (ATM) 25

ASYNCHRONOUS TRANSFER MODE (ATM-IMA) 25

TRANSPARENT LAN SERVICE (TLS) 25

ENTERPRISE 26

FAA 26

FMS 26

LAN EXTENSION SERVICE (LES) 26

BANDWIDTH ON DEMAND (BOD) 27

DEDICATED SONET RING (DSR) 27

DEDICATED SONET RING & INTELLILIGHT OPTICAL TRANSPORT SERVICE (DSR & IOTS) 28

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS) 28

INTELLILIGHT ENTRANCE FACILITY (IEF) 29

INTELLILIGHT BROADBAND TRANSPORT (IBT) 31

INTEGRATED OPTICAL SERVICES (IOS) 31

VERIZON OPTICAL NETWORK (VZON) 31

UNBUNDLED NETWORK ELEMENTS (UNE) 32

SWITCHED SERVICES 32

WEST

APPLICABLE STATES

For the purpose of this job aid, the following states are included in the West region:

ARIZONA

CALIFORNIA

FLORIDA

IDAHO

ILLINOIS

INDIANA

MICHIGAN

NEVADA

NORTH CAROLINA

OHIO

OREGON

SOUTH CAROLINA

TEXAS

WASHINGTON

WISCONSIN

WEST SPEC CODES

FRAME RELAY

|SPEC |Description |

|FRSXAL |Port + Access |

|FRSPXX |Port Only |

|FRSFXX |Port Only w/Metrolan |

|PVCFAC |Frame to ATM |

|FRSZ## |Frame Interzone, where ## indicates the # of PVCs ordered |

|FRSEF1, 2, or 3 |Port Only Fiber Transport Priority (Intrastate Only) |

|FRSEP1, 2 or 3 |Port Only Priority (Intrastate Only) |

|FRSEX1, 2 or 3 |Port w/Frame Access Priority (Intrastate Only) |

ASYNCHRONOUS TRANSFER MODE (ATM)

|SPEC |Description |

|ATMPNO |Port Only |

|ATMPT1, 2 or 3 |Port + Access |

IP VPN

|SPEC |Description |

|VPNBGP |iVC Basic or Premier |

|RPXENG |E1 Group |

|RPXOSP |OSPF |

|LANVCE |E-VC |

west spec codes

TRANSPARENT LAN SERVICE (TLS)

|SPEC |Description |

|CSMVRX |CSM |

|TLSERP |ERS Premier |

|TLSERPC |CSM + ERS Premier |

|TLSERSS |ERS Standard |

|TLSEMSR |EMS, EMS-RT Standard |

DEDICATED TRANSIT SERVICE (DTS)

|SPEC |Description |

|COLCOL |PIU= 0 Contracts for DTS |

|COLCCA |PIU = 0 or 100 (Either FCC or Intrastate Tariff) |

METROLAN TRANSPORT FOR DS1 SERVICES

|SPEC |Description |

|SPPFTS |Allows MetroLAN mileage discount where available as described in |

| |FCC tariffs. |

west spec codes

FIBERCONNECT

|SPEC |Description |

|FOL1AZ |FiberConnect at PRILOC & SECLOC |

|FOL1AX |FiberConnect at PRILOC ONLY |

|FOL1ZX |FiberConnect at SECLOC ONLY |

|FOLSPAZ |MetroLAN AND FiberConnect at PRILOC & SECLOC |

|FOLSPAX |MetroLAN AND FiberConnect at PRILOC ONLY |

|FOLSPZX |MetroLAN AND FiberConnect at SECLOC ONLY |

|FOLDSAX |DSR Rider with FiberConnect at PRILOC ONLY (CFA must be DSR) |

|FOLDSZX |DSR Rider with FiberConnect at SECLOC ONLY (CFA must be DSR) |

NEAR OUT OF FRANCHISE (NOOF)

The NOOF SPEC codes listed below are used for ASRs for the following product types:

▪ Custom Connect

▪ Verizon Optical Networking

▪ DS3

▪ DS1

|SPEC |Description |

|OOFBNP |All customers: |

| |Primary location is a NOOF location and the Secondary location is within a Verizon |

| |franchise. |

| | |

| |All facilities provided by Verizon and no Individual Case Basis (ICB) for special |

| |construction applies |

|OOFBCP |All customers: |

| |Primary location is a NOOF location and the Secondary location is within a Verizon |

| |franchise. |

| | |

| |All facilities provided by Verizon and an ICB[1] for special construction at NOOF |

| |location is required. |

|OOFTNP |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is a |

| |NOOF location. |

| | |

| |All facilities provided by Verizon and no ICB for special construction applies. |

west spec codes

NEAR OUT OF FRANCHISE (NOOF)

|OOFTCP |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |a NOOF location. |

| | |

| |All facilities provided by Verizon and an ICB[2] for special construction applies. |

|OOFOLA |All customers: |

| |Primary location is a NOOF to the Secondary location that is in a Verizon franchise |

| |location. |

| | |

| |A portion of the NOOF facilities are provided by a company other than Verizon and no ICB|

| |for special construction applies. |

|OOFTLA |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |a NOOF location. |

| | |

| |A portion of the NOOF facilities at the Primary location is provided by a company other |

| |than Verizon and no ICB for special construction applies. |

|OOFTLZ |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |a NOOF location. |

| | |

| |A portion of the NOOF facilities at the SECLOC is provided by a company other than |

| |Verizon and an ICB¹ for special construction applies. |

|OOFTAZ |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |a NOOF location. |

| | |

| |A portion of the NOOF facilities are provided by a company other than Verizon at both |

| |the Primary and Secondary locations and no ICB for special construction applies. |

| | |

|OOFOCX |All customers: |

| |Primary location is a NOOF location to the Secondary location that is in a Verizon |

| |franchise location. |

| | |

| |All facilities provided by Verizon and only ICB¹ pricing applies at NOOF location. |

west spec codes

NEAR OUT OF FRANCHISE (NOOF)

|OOFOCT |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |in a Verizon franchise location. |

| | |

| |A portion of the NOOF facilities are provided by a company other than Verizon and only |

| |ICB¹ pricing applies at the NOOF location. |

|OOFSTO |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |a NOOF location. |

| | |

| |A portion of the NOOF facilities at the Primary location and/or Secondary location is |

| |provided by a company other than Verizon and only ICB[3] pricing applies. |

|OOFSTP |All customers: |

| |Primary location is a NOOF to the Secondary location and the Secondary location is also |

| |in a NOOF location. |

| | |

| |Only ICB¹ pricing applies. |

|OOFSPO |Verizon Partner Solutions (non-retail) customers only: |

| | |

| |Prepositioned PORT facility is at a NOOF location and no ICB applies. |

|OOFSPF |VPS customers only: |

| | |

| |Prepositioned PORT facility is at a NOOF location and an ICB¹ applies. |

west spec codes

BANDED OPTICAL TRANSPORT

|SPEC |Description |

|SN1TBC |Banded Optical Transport (riders on Custom Connect, |

| |Express Connect, or Flex Express Connect) |

west spec codes

DEDICATED SONET RING (DSR)

|SPEC |Description |

|SNTESA |DSR Ring – PIU 100 |

| | |

| |DSR Ring with no Optional Pricing – PIU 000 |

|SNTESA |DSR Ring riders PIU 100/0 |

|SPCXXX |DSR Partial Ring rider when one location is a NODE and the other location is an APOI |

| |or ZPOI. |

|OTSBAX |DSR Partial Ring rider when neither the A or Z location is a Verizon location. |

|SNTOAP |Dedicated SONET Ring with Optional Pricing (OAP) PIU 0. |

|DS14PR |ISDN PRI DS1 – PIU 0 |

|DS1OAP |ISDN PRI DS1 with OAP. |

| | |

| |In CA only, used for DWR (PIU 0) |

|SNTDSH |Used to identify APF = SNTDSH for PIU 100 or PIU 0 without OAP. |

|SNTDS2 |Used to identify a rider with an APF at both ends for PIU 100 or PIU 0 without OAP. |

|SNTDOP |Used to identify an Asymmetrical Port Facility with OAP: PIU 0 only. |

|SNTDO2 | Used to identify a rider on two Asymmetrical Port Facilities on the same ring – PIU |

| |0 only. |

|CSMVXX |DSR ring with CSM. Service Level 1 |

| |View Feature – PIU 100 |

|CSMVRX |DSR ring with CSM Service Level 2 |

| |View Feature and generate reports – PIU 100 |

|CSMVRR |DSR ring with CSM Service Level 3 |

| |View Feature, generate reports and Reconfiguration Feature – PIU 100 |

|VXXOAP |DSR ring with CSM Service Level 1 |

| |View Feature with OAP, PIU 0 only |

|VRXOAP |DSR ring with CSM Service Level 2 |

| |View Feature and generate reports with OAP, PIU 0 only |

|VRROAP |DSR ring with CSM Service Level 3 |

| |View Feature, generate reports and Reconfiguration Feature with OAP, PIU 0 only |

west spec codes

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS)

|SPEC |Description |

|OTSLTX |Special Link Termination. Can be ordered at a location on the Primary or the Expansion |

| |Ring IOTS –PIU 100/0 |

|OTSEXX |Expansion Ring Without CSM |

|OTSCSM |IOTS Full Ring with Customer Service Management (CSM) |

|OTSMDW |IOTS Optical Transport channel for service that “Rides” a Multi-Port Facility. |

|OTSLTX |Special Access Link Termination Without Node or Amplification – Primary IOTS Ring |

|OTSEXX |Expansion Node with No Node Amplification. Expansion IOTS Ring. |

|OTSLTX |Special Access Link Termination Without Node or Amplification – Expansion IOTS Ring. |

|OTSPCSM |IOTS Partial Ring with Customer Service Management (CSM) |

|OTSPTLM |IOTS Partial Ring with Direct TL1 Management (DTM) |

|OTSTLM |IOTS Full Ring with DTM |

|OTCMOAP |DWR Full Ring with CSM for OAP, PIU 000 only |

|OTDMOAP |DWR Full Ring with DTM for OAP, PIU 000 only |

|VNOSF |All services for Integrated Optical Service including On and Off the IOS network. |

| |IOS DWDM Ring |

| |IOS Ring on Ring |

| |IOS Point to Point Facility |

| |IOS On Ring riders |

| |IOS Off Ring riders |

|SNTVON |Verizon Optical Network Aggregation Port Facility |

west spec codes

INTELLILIGHT ENTRANCE FACILITY (IEF)

|SPEC |Description |

|SNTHHD |OC3 IEF STUB HUB |

|SNTHHD |OC12 IEF STUB HUB |

|SNTHHD |OC48 MidSpan Meet |

|SNTHHD |OC3/OC3c, OC12/OC12c, DS3, VON Riders on Stub Hub or MSM |

|SALTL4L |OC3/OC3c, OC12/OC12c, DS3, VON Connecting to IEF like-to-like |

| |Interface |

|SALTLCL |OC3/OC3c, OC12/OC12c, DS3, VON, collocation connecting to IEF |

| |like-to-like Interface |

ETHERNET PACKET RING SERVICE (EPRS)

|SPEC |EPRS Ring |

|SNTESA |All Speeds and Bandwidths |

|SPEC |EPRS UNI |

|SNTESA |All Speeds and Bandwidths |

west spec codes

VERIZON OPTICAL NETWORKING (VZON)

|SPEC |Description |

|SNTVON |VzON Access Aggregation Port |

|OOFBNP |VzON NOOF to In-franchise |

|AGGOAP |VzON Aggregation Port with Optional Pricing, PIU 0 only |

|OOFBCP |VzON NOOF to In-franchise with Construction ICB |

|OOFTNP |VzON NOOF to NOOF |

|OOFTCP |VzON NOOF to NOOF with Construction ICB |

UNBUNDLED NETWORK ELEMENTS (UNE)

|SPEC |Description |

|UNBALL |UNE IOFand Dark Fiber |

|UNB1OT |Enhanced Extended Loop (EEL) |

Switched Services (including ss7)

|SPEC |Description |

|ONSXXX |SS7 OffNet |

|SS7MW |SS7 Message Waiting Indicator (MWI) |

|GATEWAY |SS7 Gateway Access Service (Initial ASR) |

|GTWY# (where # = 1, 2, 3, etc.) |SS7 Gateway Access Service (Subsequent ASRs incremented) |

|POVNAC |Point of Interface on VZ Network (POVN) Access Transport |

|OFNMSF |Local Interconnection Services (PIU 0) Mid Span Fiber Meet |

NORTH

APPLICABLE STATES

For the purpose of this job aid, the following states are included in the North region:

CONNECTICUT

MAINE

MASSACHUSETTS

NEW HAMPSHIRE

NEW YORK

RHODE ISLAND

VERMONT

NORTH SPEC CODES

FRAME RELAY

|SPEC |Description |

|FRDS### |Port + Access Subrate DS3 |

|ENSDTS |Enterprise Port Only 56K** |

|ENSPK1 |Enterprise Port Only |

|FRSTPP |FRS DS3 Packet Switch |

|FRSTPA |FRS DS2 Access Point |

|FRSTPF |FRS DS3 All Other |

ASYNCHRONOUS TRANSFER MODE (ATM)

|SPEC |Description |

|ATMFUX, 1UX, SPX |Port Only |

|ATMFUX, 1UX, SPX, FUP, 1UP , SPP |Port + Access |

ASYNCHRONOUS TRANSFER MODE (ATM IMA)

|SPEC |Description |

|ATMFUX |Port + Access |

TRANSPARENT LAN SERVICE (TLS)

|SPEC |Description |

|CSMVRX |CSM |

|TLSERP |ERS Premier |

|TLSERPC |CSM + ERS Premier |

|LANVCX |Corridor |

|TLSEMCC |Corridor + CSM |

|TLSERC |ERS Premier + Corridor |

|TLSERCC |ERS Premier + Corridor + CSM |

|TLSERSS |ERS Standard |

|TLSEMSR |EMS, EMS-RT |

north spec codes

ENTERPRISE

|SPEC |Description |

|ENSPK1 |Standard Enterprise Service |

|ENSDCS |ES DS0 Prime Service |

|ENSDTS |ES DS0 Standard Service |

|ENSCOR |ES multiplexed/groomed and point to point service in the New |

| |York/New Jersey Corridor region |

Facility Management Service (FMS)

|SPEC |Description |

|FMSXXX |Facility Management Service – Telco Managed Engineering & Design |

| |of Network |

|FMSXX3 |Facility Management Service – Telco Managed Engineering & Design |

| |of Network – three (3) year plan |

|FMSXX5 |Facility Management Service – Telco Managed Engineering & Design |

| |of Network – five (5) year plan |

LAN Extension Service (LNS)

|SPEC |Description |

|LAX1GB |LAN Extension Service – Fiber Transport |

VZON CONNECTED TO ACCESS AGGREGATION PORT

|SPEC |Description |

|SNTVON |Used to order an OC3, OC12, and OC48 VzON Access Aggregation Port|

| |as well as the derived circuits. |

north spec codes

VZON CONNECTED TO A DSR

|SPEC |Description |

|SNTESA |Channels derived from a DSR – No asymmetrical ports. |

| | |

| |Configurations are Native to Sonet mapped for all VzON. In |

| |addition: for GigE Ethernet, FICON and Fibre Channel, it is |

| |available in Native-Native configuration as well. |

|SNTDSH |Derived from DSR – with asymmetrical ports |

VZON CONNECTED TO IEF STUB HUB OR MID SPAN MEET

|SPEC |Description |

|SNTHHD |Derived from an asymmetrical port |

BANDWIDTH ON DEMAND (BOD)

|SPEC |Description |

|BODFAC |Bandwidth On Demand (BOD) Facility (used for facilities and |

| |off-ring riders) |

|BODORC |Bandwidth On Demand (BOD) on-ring channel |

north spec codes

DEDICATED SONET RING (DSR)

|SPEC |Description |

|SNTDOR |SONET- Dedicated Ring – on-ring channel |

|SNTDS2 |Service is derived from asymmetrical SONET ports (stub-hubs) at |

| |both ends (riders on different rings w/asymmetrical ports at each|

| |end of circuit) |

|SNTDSH |SONET- Dedicated Ring- Stub-Hub (used for ordering asymmetrical |

| |port & off-ring riders) |

|SNTESA |Enhanced IntelliLight Dedicated SONET Ring (IDSR), special |

| |access; ring & off-ring riders |

|SNTESW |Enhanced IntelliLight Dedicated SONET Ring (IDSR), switched |

| |access; ring and off-ring riders |

|SPCXXX |Single port charge (rider on partial-ring DSR, getting on/off at |

| |fiber meet) |

|CSMVXX |CSM Level I: View |

|CSMVRX |CSM Level II: View and Report |

|CSMVRR |CSM Level III: View, Report, and Reconfigure |

DEDICATED SONET RING & INTELLILIGHT OPTICAL TRANSPORT SERVICE

|SPEC |Description |

|PARTRNG |Partial Ring Service |

north spec codes

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS)

|SPEC |Description |

|DTMXXX |Direct TL1 Monitoring on DSR for Dedicated Wavelength Ring |

|OTSBAX |Optical Transport Service – Service Originates and Terminates in |

| |LATA B but traverses LATA A |

|OTSCSM |IntelliLight Optical Transport Service (IOTS) with Customer |

| |Service Management (CSM) |

|OTSDRS |Optical Transport Service – Dense wave Division Multiplexing Ring|

| |for Switched Access |

|OTSDSR |Switched DSR ring riding IOTS |

|OTSMDW |Optical Transport Service Derived from a Sub-Rate Multiplexed |

| |DWDM (Dense Wavelength Division Multiplexing) Platform (MPIC |

| |facility and on-ring rider) |

|OTSPCSM |Partial IntelliLight Optical Transport Service (IOTS) with |

| |Customer Service Management (CSM) |

|OTSPTLM |Partial IntelliLight Optical Transport Service (IOTS) with Direct|

| |TL1 Management (DTM) |

|OTSTLM |IntelliLight Optical Transport Service (IOTS) with Direct TL1 |

| |Management (DTM) |

|PARCSMN |Partial Ring with Customer Service Management - View, Customer |

| |Generated Network Performance Reports & Network Reconfiguration |

|PARCSMR |Partial Ring with Customer Service Management – View & Customer |

| |Generated Network Performance Reports |

|PARCSMV |Partial Ring with Customer Service Management – View Only |

north spec codes

INTELLILIGHT ENTRANCE FACILITY (IEF)

|SPEC |Description |

|SALTAX |SONET Access Loop Termination – Point to Point DS3 ordered over |

| |IEF like-to-like arrangement |

|SALTBX |SONET Access Loop Termination – Muxed DS3 ordered over IEF |

| |like-to-like arrangement |

|SALTC2 |SONET Access Loop Termination – record Order STS1 Circuit – |

| |Billing Only (for use with DS1 like-to-like) |

|SALTEX |SONET Access Loop Termination – Muxed STS1 |

|SALTFX |SONET Access Loop Termination – OC03/OC03c riding OC12 stub-hub |

| |or OC48 mid-span meet at PRILOC or SECLOC |

|SALTGX |SONET Access Loop Termination – OC12/OC12c riding OC48 mid-span |

| |meet at PRILOC or SECLOC |

|SALTHX |SONET Access Loop Termination – Point to Point DS1 Electrical |

| |Interface – associated with record order STS1 |

|SALTY2 |SONET Access Loop Termination – OC03/OC03c like-to-like at SECLOC|

| |– no entrance facility at PRILOC |

|SALTYX |SONET Access Loop Termination – OC03/OC03c like-to-like at PRILOC|

| |– no entrance facility at SECLOC |

|SALTZ2 |SONET Access Loop Termination – OC12/OC12c like-to-like at SECLOC|

| |– no entrance facility at PRILOC |

|SALTZX |SONET Access Loop Termination – OC12/OC12c like-to-like at PRILOC|

| |– no entrance facility at SECLOC |

|SNTHHD |SONET – self-healing – hubbed drop – used to order IEF |

| |stub-hub/mid-span meet |

|SNTRN2 |ISDN Riding SONET (DS1 PRI derived from IntelliLight Entrance |

| |Facility (IEF) |

|SNTRN3 |ISDN Riding SONET (DS1 PRI derived from IntelliLight Broadband |

| |Transport (IBT) |

north spec codes

INTELLILIGHT BROADBAND TRANSPORT (IBT)

|SPEC |Description |

|SNTLBT1 |Derived from IntelliLight Broadband Transport (IBT) with a single|

| |multiplexer on premise |

|SNTLBT2 |Derived from IntelliLight Broadband Transport (IBT) with a single|

| |multiplexer at Central Office (CO) |

|SNTLBT3 |Derived from IntelliLight Broadband Transport (IBT) with |

| |multiplexers at both Central Office (CO) and premise locations |

|SNTLBT4 |Derived from IntelliLight Broadband Transport (IBT) with |

| |multiplexers at both premises |

|SNTMUX |SONET – based switched access/special access wire center or |

| |customer premises multiplexing |

|SNTMUY |SONET – based switched access/special access wire center and |

| |customer premises multiplexing |

VERIZON INTEGRATED OPTICAL SERVICES (VIOS)

|SPEC |Description |

|VNOSF |Verizon Integrated Optical Service (VIOS) facility |

| |(rings/point-to-point optical facilities & off-ring riders) |

|VNOSORC |Verizon Integrated Optical Service (VIOS) on-ring channel |

VERIZON OPTICAL NETWORK (VZON)

|SPEC |Description |

|SNTVON |VzON (Verizon Optical Network) Ethernet aggregation port (for |

| |ordering both the port and the rider) |

north spec codes

UNBUNDLED NETWORK ELEMENTS (UNE)

|SPEC |Description |

|UNB1OT |UNE EEL |

|UNBALL |UNE IOF, Dark Fiber & Loop |

SWITCHED SERVICES (including ss7)

|SPEC |Description |

|CMPMRE |CLEC MOU MEET POINT A (End Office) |

|CMPMRT |CLEC MOU MEET POINT B (Tandem) |

|CMPMUE |CLEC MOU MEET POINT A (End Office) |

|CMPMUT |CLEC MOU MEET POINT B (Tandem) |

|OFNMSF |Local Interconnection Services (PIU 0) Mid Span Fiber Meet |

|ONSXXX |SS7 OffNET |

|POVNAC |Point of Interface on VZ Network (POVN) Access Transport |

|SNTESW |Derived from DSR–No asymmetrical ports. Configurations are |

| |Native-to-Sonet-mapped for all VzON, in addition:for GigE |

| |Ethernet, FICON and Fibre Channel, it is available in |

| |Native-Native configuration as well. |

|SRASGR |Subsequent Gateway Access Service |

|SRASGW |Original Gateway Access Service |

|SS7MW |SS7 Message Waiting Indicator |

SOUTH

APPLICABLE STATES

For the purpose of this job aid, the following states are included in the South region :

DELAWARE

DISTRICT OF COLUMBIA

MARYLAND

NEW JERSEY

PENNSYLVANIA*

VIRGINIA*

WEST VIRGINIA

*Includes former GTE or ConTel areas of Pennsylvania or Virginia.

SOUTH SPEC CODES

FRAME RELAY

|SPEC |Description |

|FRSA## |Frame Relay Service – Additional Permanent Virtual Circuits |

ASYNCHRONOUS TRANSFER MODE (ATM)

|SPEC |Description |

|ATMFUX, 1UX, SPX |Port Only |

|ATMFUX, 1UX, SPX, FUP, 1UP , SPP |Port + Access |

ASYNCHRONOUS TRANSFER MODE IMA (2-6 DS1s) - 3 Mbps to 9Mbps (Full bandwidth only)

|SPEC |Description |

|ATMFUX |Port + Access |

TRANSPARENT LAN SERVICE (TLS)

|SPEC |Description |

|CSMVRX |CSM – View & Customer Generated Network Performance Reports |

|TLSEMCC |Corridor + CSM |

|TLSERP |Transparent LAN Service - Ethernet Relay Service - Premier UNI |

|TLSERPC |Transparent LAN Service (TLS) Ethernet Relay (ERS) Premier with |

| |CSM |

|TLSERSS |ERS Standard |

|TLSEMSR |EMS, EMS-RT |

south spec codes

ENTERPRISE

|SPEC |Description |

|ENSCOR |ES multiplexed/groomed and point to point service in the New |

| |York/New Jersey Corridor (LATA 132) |

Federal Aviation Administration (FAA)

|SPEC |Description |

|FAATT |FAA Telecommunications Infrastructure |

FACILITY MANAGEMENT SERVICE (FMS)

|SPEC |Description |

|FMSXXX |Facility Management Service – Telco Managed Engineering & Design |

| |of Network |

|FMSXX3 |Facility Management Service – Telco Managed Engineering & Design |

| |of Network – three (3) year plan |

|FMSXX5 |Facility Management Service – Telco Managed Engineering & Design |

| |of Network – five (5) year plan |

LAN EXTENSION SERVICE (LES)

|SPEC |Description |

|LANVCX |Virtual Local Area Network (VLAN) Connection |

|LAX1GB |LAN Extension Service – Fiber Transport |

south spec codes

BANDWIDTH ON DEMAND (BOD)

|SPEC |Description |

|BODFAC |Bandwidth On Demand (BOD) Facility (used for facilities and |

| |off-ring riders) |

|BODORC |Bandwidth On Demand (BOD) on-ring channel |

DEDICATED SONET RING (DSR)

|SPEC |Description |

|SNTDOR |SONET Dedicated Ring – on-ring channel |

|SNTDS2 |Service derived from asymmetrical SONET ports (stub-hubs) at both|

| |ends (riders on different rings w/asymmetrical ports at each end |

| |of circuit) |

|SNTDSH |SONET Dedicated Ring- Stub-Hub (used for ordering asymmetrical |

| |port & off-ring riders) |

|SNTESA |Enhanced IntelliLight Dedicated SONET Ring (IDSR), special |

| |access; ring & off-ring riders |

|SNTESW |Enhanced IntelliLight Dedicated SONET Ring (IDSR), switched |

| |access; ring and off-ring riders |

|SPCXXX |Single port charge – Rider that originate/terminate at Partial |

| |Ring Fiber Meet |

|CSMVXX |CSM Level I: View |

|CSMVRX |CSM Level II: View and Report |

|CSMVRR |CSM Level III: View, Report, and Reconfigure |

south spec codes

DEDICATED SONET RING & INTELLILIGHT OPTICAL TRANSPORT SERVICE (DSR & IOTS)

|SPEC |Description |

|PARTRNG |Partial Ring Service |

INTELLILIGHT OPTICAL TRANSPORT SERVICE (IOTS)

|SPEC |Description |

|DTMXXX |Direct TL1 Monitoring on DSR for Dedicated Wavelength Ring |

|OTSBAX |Optical Transport Service – Service Originates and Terminates in |

| |LATA B but traverses LATA A |

|OTSCSM |IntelliLight Optical Transport Service (IOTS) with Customer |

| |Service Management (CSM) |

|OTSDRS |Optical Transport Service – Dense wave Division Multiplexing Ring|

| |for Switched Access |

|OTSDSR |Switched DSR ring riding IOTS |

|OTSMDW |Optical Transport Service Derived from a Sub-Rate Multiplexed |

| |DWDM (Dense Wavelength Division Multiplexing) Platform (MPIC |

| |facility and on-ring rider) |

|OTSPCSM |Partial IntelliLight Optical Transport Service (IOTS) with |

| |Customer Service Management (CSM) |

|OTSPTLM |Partial IntelliLight Optical Transport Service (IOTS) with Direct|

| |TL1 Management (DTM) |

|OTSTLM |IntelliLight Optical Transport Service (IOTS) with Direct TL1 |

| |Management (DTM) |

|PARCSMN |Partial Ring with Customer Service Management - View, Customer |

| |Generated Network Performance Reports & Network Reconfiguration |

|PARCSMR |Partial Ring with Customer Service Management – View & Customer |

| |Generated Network Performance Reports |

|PARCSMV |Partial Ring with Customer Service Management – View Only |

south spec codes

INTELLILIGHT ENTRANCE FACILITY (IEF)

|SPEC |Description |

|SALTAX |SONET Access Loop Termination - Point to Point DS3 ordered over |

| |IEF like-to-like arrangement |

|SALTBX |SONET Access Loop Termination - Muxed DS3 ordered over IEF |

| |like-to-like arrangement |

|SALTC2 |SONET Access Loop Termination - Record Order STS1 Circuit - |

| |Billing Only (for use with DS1 like-to-like) |

|SALTEX |SONET Access Loop Termination - Muxed STS1 |

|SALTFX |SONET Access Loop Termination - OC03/OC03c riding OC12 stub-hub |

| |or OC48 mid-span meet at PRILOC or SECLOC |

|SALTGX |SONET Access Loop Termination - OC12/OC12c riding OC48 mid-span |

| |meet at PRILOC or SECLOC |

|SALTHX |SONET Access Loop Termination - Point to Point DS1 Electrical |

| |Interface - assoc. with record order STS1 |

|SALTHX |SONET Access Loop Termination – Point to Point DS1 Electrical |

| |Interface – associated with record order STS1 |

|SALTSX |SONET Access Loop Termination - STS1 Entrance Facility Loop with |

| |VT1.5 Grooming (associated with separated DS1s) |

|SALTY2 |SONET Access Loop Termination - OC03/OC03c like-to-like at SECLOC|

| |- no entrance facility at PRILOC |

|SALTYX |SONET Access Loop Termination - OC03/OC03c like-to-like at PRILOC|

| |- no entrance facility at SECLOC |

|SALTZ2 |SONET Access Loop Termination - OC12/OC12c like-to-like at SECLOC|

| |- no entrance facility at PRILOC |

south spec codes

INTELLILIGHT ENTRANCE FACILITY (IEF)

|SPEC |DESCRIPTION |

|SALTZX |SONET Access Loop Termination - OC12/OC12c like-to-like at PRILOC|

| |- no entrance facility at SECLOC |

|SNTHHD |SONET - self-healing - hubbed drop--used to order IEF |

| |stub-hub/mid-span meet |

|SNTRN2 |ISDN Riding SONET (DS1 PRI derived from Intellilight Entrance |

| |Facility (IEF)) |

|SNTRN3 |ISDN Riding SONET (DS1 PRI derived from Intellilight Broadband |

| |Transport (IBT) multiplexing) |

south spec codes

INTELLILIGHT BROADBAND TRANSPORT (IBT)

|SPEC |Description |

|SNTLBT1 |Derived from IntelliLight Broadband Transport (IBT) with a single|

| |multiplexer on premise |

|SNTLBT2 |Derived from IntelliLight Broadband Transport (IBT) with a single|

| |multiplexer at Central Office (CO) |

|SNTLBT3 |Derived from IntelliLight Broadband Transport (IBT) with |

| |multiplexers at both Central Office (CO) and customer premises |

| |locations |

|SNTLBT4 |Derived from IntelliLight Broadband Transport (IBT) with |

| |multiplexers at both premises |

|SNTMUX |SONET – based switched access/special access wire center or |

| |customer premises multiplexing |

|SNTMUY |SONET – based switched access/special access wire center and |

| |customer premises multiplexing |

INTEGRATED OPTICAL SERVICES (IOS)

|SPEC |Description |

|VNOSF |Integrated Optical Service (IOS) facility (rings/point-to-point |

| |optical facilities & off-ring riders) |

|VNOSORC |Integrated Optical Service (IOS) on-ring channel |

VERIZON OPTICAL NETWORK (VZON)

|SPEC |Description |

|SNTVON |Verizon Optical Network (VzON) Ethernet aggregation port (for |

| |ordering both the port and the rider) |

south spec codes

UNBUNDLED NETWORK ELEMENTS (UNE)

|SPEC |Description |

|UNB1OT |UNE EEL |

|UNBALL |UNE IOF, Dark Fiber and Loop |

SWITCHED SERVICES (including ss7)

| |Description |

|SPEC | |

|CMPM1X |CLEC Interconnection/Meet Point Termination – Minutes of Use Rate |

| |Schedule – 1-way Terminating Facility |

|CMPMRE |CLEC MOU MEET POINT A (End Office) |

|CMPMRT |CLEC Interconnection/Meet Point Termination – Minutes of Use Rate |

| |Schedule –– Tandem – Trunk Connection – 2 way Trunk Service |

|CMPMUE |CLEC Two way trunks – No Collocation involved |

|CMPMUT |CLEC Interconnection/Meet Point Termination - Minutes of Use Rate |

| |Schedule – Tandem |

|GATEWAY |Original Gateway Access Service |

|GTWY# (where # = an actual number) |Subsequent Gateway Access Service |

|LSPSET |Local Service Provider – Facility Billed via Settlement Process |

|OFNMSF |Local Interconnection Services (PIU 0) Mid Span Fiber Meet |

|ONSXXX |SS7 OffNET |

|PHDS1M |Physical Collocation – Two way trunks - DS1 interface |

|PHDS3M |Physical Collocation – Two way trunks - DS3 interface |

|POVNAC |Point of Interface on VZ Network (POVN) Access Transport |

|SPOLATA |Single Point of Presence (SPOP) in LATA in support of Local |

| |Interconnection Service (LIS). Service can cross Public Utility |

| |Commission (PUC) defined Local Calling Area (LCA) boundary |

|SS7MW |SS7 Message Waiting Indicator |

|VTDS1M |Virtual Collocation – Two way trunks - DS1 interface |

|VTDS3M |Virtual Collocation – Two way trunks - DS3 interface |

|WPAGE |Wireless Paging Service |

-----------------------

[1] When an ICB applies the following remarks are required on the ASR: ICB# xxxxxx;;ICB USOC xxxxx; If more than one USOC then use: ICB# xxxxxx;;ICB USOC xxxxx, xxxxx.

[2] ¹When an ICB applies the following remarks are required on the ASR: ICB# xxxxxx;;ICB USOC xxxxx; If more than one USOC then use: ICB# xxxxxx;;ICB USOC xxxxx, xxxxx.

[3] When an ICB applies, the following remarks are required on the ASR: ICB# xxxxxx: ICB USOC xxxxx: If more than one USOC then use: ICB# xxxxxx: ICB USOC xxxxx, xxxxx.

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download