 SECTION 08 80 00GLASSDisplay hidden notes to specifier. (Don't know how? Click Here) Copyright 2018 - 2018 ARCAT, Inc. - All rights reserved** NOTE TO SPECIFIER ** Viracon; architectural glass.This section is based on the products of Viracon, which is located at:800 Park Dr. P. O. Box 990Owatonna, MN 55060Toll Free Tel: 800-533-2080Tel: 507-451-9555Fax: 507-444-3555Email: request info (glass@)Web: [ Click Here ] for additional information.All architectural glass fabricators may start out the same but that's where any similarity ends. It's what each fabricator brings to your project that makes all the difference. From aesthetics, to strict environmental and energy specifications, to critical budget and delivery requirements, our input can make a difference. The fact is, our selection of innovative architectural glazing options combined with specification assistance and technical expertise can help make your vision a reality. Viracon is your single-source resource for innovative products, reliable service, valuable advice and technical expertise for Insulating, High-Performance Coatings, Insulating Laminated, Protective, Edgework, Laminated, Triple Insulating, Spandrel, Acoustical, Holes / Notches, Monolithic, Silk-Screened, Green Design, and Heat-Treated Glass.

GENERAL

SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

Glass Types Including:

Flat glass.

Insulating glass.

Laminated glass.

Sputter-coated vision glass

Ceramic coated glass.

Glass Assemblies Including:

Insulating coated glass.

Laminated coated glass.

Monolithic reflective glass.

Insulating laminated coated glass.

RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

Section 08 41 13 - Aluminum-Framed Entrances and Storefronts.

Section 08 44 16 - Glazed Bronze Curtain Walls.

REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

American National Standards Institute (ANSI):

ANSI Z97.1 - Performance Specifications and Methods of Test for Safety Glazing Materials Used in Buildings.

American Society for Quality Control (ASQC).

ASTM International (ASTM):

ASTM C 1036 - Standard Specification for Flat Glass.

ASTM C 1048 - Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass.

ASTM C 1172 - Standard Specification for Laminated Architectural Flat Glass.

ASTM C 1376 - Standard Specification for Pyrolytic and Vacuum Deposition Coatings on Flat Glass.

ASTM E 546 - Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units.

ASTM E 576 - Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units in the Vertical Position.

ASTM E 1300 - Standard Practice for Determining Load Resistance of Glass in Buildings.

ASTM E 2190 - Standard Specification for Insulating Glass Unit Performance and Evaluation (replaces ASTM E773, E774 CBA, CAN / CGSB 12.8).

British Standard (BS):

BS EN 14179 - Glass in building - Heat-soaked thermally-toughened soda lime silicate safety glass.

Consumer products Safety Council (CPSC):

CPSC 16 CFR 1201 - Safety Standard for Architectural Glazing Materials.

Glass Association of America (GANA).

GANA Glazing Manual.

GANA Engineering Standards Manual.

GANA Laminated Glazing Reference Manual.

International Standards Organization (ISO):

ISO 9001: 2015 - Quality Systems -- Model for Quality Assurance in Production, Installation, and Servicing.

DEFINITIONS

Abbreviations and Acronyms:

AN, Annealed.

FT, Fully Tempered.

HS, Heat-strengthened.

IGCC, Insulating Glass Certification Council.

IGMA, Insulating Glass Manufacturers Alliance.

LBNL, Lawrence Berkeley National Laboratories.

Low-E, Low emissivity.

LSG, Light to Solar Gain.

NFRC, National Fenestration Rating Council.

SHGC, Solar Heat Gain Coefficient.

SC, Shading Coefficient.

VLT, Visible Light Transmittance.

SUBMITTALS

Submit under provisions of Section 01 30 00 - Administrative Requirements.

Product Data:

Manufacturer's data sheets on each product to be used.

Preparation instructions and recommendations.

Storage and handling requirements and recommendations.

Typical installation methods.

Samples: Submit 12 inches (305 mm) long samples of each type of glass indicated except for clear monolithic glass products and make-ups with Viracon Thermal Spacer (VTS), and 12 inches (305 mm) long samples of each color required, except black, for each type of sealant or gasket exposed to view.

Test and Evaluation Reports: Glazing contractor shall obtain compatibility and adhesion test reports from sealant manufacturer indicating that glazing materials were tested for compatibility and adhesion with glazing sealant as well as other glazing materials including insulating units.

** NOTE TO SPECIFIER ** Delete if not required.

Sustainable Design Submittals: Submit manufacturer's documentation verifying product content, origin or other attributes for projects requiring special sustainability provisions, to meet the USGBC's LEED requirements or other sustainable goals.

QUALITY ASSURANCE

Manufacturers: Fabrication processes, including low emissivity and reflective coatings, insulating, laminated, silk-screening and tempering shall be manufactured by a single manufacturer with a minimum of ten years of fabrication experience and meet ISO 9001: 2015.

Installer Qualifications: Company specializing in performing Work of this section withminimum two years documented experience with projects of similar scope and complexity.

Publications: Comply with recommendations in the publications below, except where more stringent requirements are indicated. Refer to these publications for glazing terms not otherwise defined in this section or in Article 1.3 References.

GANA Glazing Manual.

GANA Engineering Standards Manual.

GANA Laminated Glazing Reference Manual.

Source Limitations: Obtain glass and glazing materials from one source for each product indicated. Coatings and finished assemblies, such as insulating units and laminated units, shall be manufactured by the same fabricator in order to have a common source of warranty.

** NOTE TO SPECIFIER ** Include mock-up if the project size or quality warrant the expense. The following is one example of how a mock-up on might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project. Delete if not required.

Mock-ups: Before glazing, build mockups for each glass product indicated in the Product Schedule to verify selections and to demonstrate aesthetic effects and qualities of materials and execution.

Construction: Build mockups with glass and glazing systems specified for the project, including typical lite size, framing systems and glazing methods.

Scheduling: Notify architect seven days in advance of dates and times when mockups will be available for viewing.

Quality Assurance: Maintain mockups during construction in an undisturbed condition as a standard for judging the completed work. Accepted mockups may become part of the completed work if undisturbed at the time of substantial completion.

PRE-INSTALLATION CONFERENCE

Convene a conference approximately two weeks before scheduled commencement of the Work. Attendees shall include Architect, Contractor and trades involved. Agenda shall include schedule, responsibilities, critical path items and approvals.

DELIVERY, STORAGE, AND HANDLING

Store and handle in strict compliance with manufacturer's written instructions and recommendations.

Protect glass from edge damage during handling. For insulating units exposed to substantial altitude changes, comply with insulating glass manufacturers written recommendations for venting and sealing to avoid hermetic seal ruptures.

Storage and Protection: Protect glazing materials according to manufacturer's written instructions and as needed to prevent damage to glass and glazing materials from condensation, temperature changes, direct exposure to sun or other causes.

Protect from damage due to weather, excessive temperature, and construction operations.

PROJECT CONDITIONS

Ambient Conditions: Do not proceed with glazing when ambient and substrate temperature conditions are outside limits permitted by the glazing material manufacturers and when glazing channel substrates are wet from rain, frost, condensation or other causes.

Do not install liquid glazing sealants when ambient and substrate temperature conditions are outside limits permitted by glazing sealant manufacturer or below 40 degrees F (4.4 degrees C).

SEQUENCING

Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

WARRANTY

Manufacturer's Warranty: Provide manufacturer's standard limited warranty.

Warranties:

** NOTE TO SPECIFIER ** Delete warranty options not required based on glass types and assemblies specified.

Heat-Soaked Tempered Glass: Provide a written 10-year warranty from date of manufacture for fully tempered glass that has been Heat Soaked. Warrants that heat soaked tempered glass will not break spontaneously as a result of Nickel Sulfide (NiS) inclusions at a rate exceeding 0.3 percent (3/1000) for a period of 10 years from the date of manufacture.

Laminated Glass: Provide a written 10-year warranty from date of manufacture for laminated glass. Warranty covers deterioration due to normal conditions of use and not to handling, installing, and cleaning practices contrary to the glass manufacturer's published instructions.

Insulating Glass: Provide a written 10-year warranty from date of manufacture for insulating glass. Warranty covers deterioration due to normal conditions of use and not to handling, installing, protecting and maintaining practices contrary to the glass manufacturer's published instructions.

Insulating Glass with Thermal Spacer: Provide a written 12-year warranty from date of manufacture for insulating glass with a Viracon Thermal Spacer (VTS). Warranty covers deterioration due to normal conditions of use and not to handling, installing, protecting and maintaining practices contrary to the glass manufacturer's published instructions.

Sputter Coated Glass: Provide a written 10-year warranty from date of manufacture for sputter coated glass. Warranty covers deterioration due to normal conditions of use and not to handling, installing, and cleaning practices contrary to the glass manufacturer's published instructions.

Ceramic Frit on Glass: Provide a written 10-year warranty from date of manufacture for Viraspan ceramic frit including Digital Distinctions digitally printed ceramic ink. Warranty covers deterioration due to normal conditions of use and not to handling, installing, and cleaning practices contrary to the glass manufacturer's published instructions.

PRODUCTS

MANUFACTURERS

Acceptable Manufacturer: Viracon, which is located at: 800 Park Dr. P. O. Box 990; Owatonna, MN 55060; Toll Free Tel: 800-533-2080; Tel: 507-451-9555; Fax: 507-444-3555; Email: request info (glass@); Web:

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

Substitutions: Not permitted.

Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

PERFORMANCE AND DESIGN REQUIREMENTS

Performance: Provide glazing systems capable of withstanding normal thermal movements, wind loads and impact loads, without failure, including loss due to defective manufacture, fabrication and installation; deterioration of glazing materials; and other defects in construction.

Glass Strength: Analysis shall comply with ASTM E 1300 Determining Load Resistance of Glass in Buildings. Provide glass products in the thickness and strengths (annealed or heat-treated) required to meet or exceed the following criteria based on project loads and in-service conditions.

Minimum thickness of annealed or heat-treated glass products to be selected so the worst case probability of failure does not exceed the following:

Breaks: 8 breaks per 1000 for glass installed vertically or not 15 degrees or more from the vertical plane and under wind action.

Breaks: 1 break per 1000 for glass installed 15 degrees or more from the vertical plane and under action of wind and/or snow.

Deflection: Limited to prevent disengagement from the frame and be less than or equal to 1 inch (25 mm).

Thermal and Optical Performance: Provide glass products with performance properties specified in the Product Schedule. Performance properties to be manufacturer's published data as determined according to the following procedures:

Center of glass U-Value: NFRC 100 methodology using LBNL WINDOW 7 computer program.

Center of glass solar heat gain coefficient: NFRC 200 methodology using LBNL-35298 WINDOW 7 computer program.

Solar optical properties: NFRC 300.

FABRlCATlON

** NOTE TO SPECIFIER ** Always retain flat glass paragraph.

Flat Glass:

Shall comply with ASTM C1036 Standard Specification for Flat Glass, Type 1, Class 1 (clear) or Class 2 (tinted, heat-absorbing and light reducing) and Quality q3

** NOTE TO SPECIFIER ** Delete ASTM C 1048 if annealed glass is being specified.

Shall comply with ASTM C 1048 Heat Treated Flat Glass, Kind HS or FT, Condition A (uncoated), B (spandrel glass, one surface coated), or C (other coated glass).

Heat Treated Flat Glass manufactured by horizontal (roller hearth) process with inherent roller wave distortion parallel to the bottom edge of the glass as installed, except in the following applications: glass units with ceramic frit and base dimensions greater than 84 inches (2134 mm), 1/2 inch (12 mm) thick glass and base dimensions greater than 84 inches (2134 mm) and all other configurations with base dimensions greater than 96 inches (2438 mm).

Maximum peak to valley roller wave 0.003 inch (0.08 mm) in the central area and 0.008 inch (0.20 mm) within 11.3 inch (287 mm) of the leading and trailing edge.

For clear or low-iron glass 1/4 to 3/8 inch (6 to 10 mm) thick without ceramic frit or ink, maximum plus or minus 100 mD (millidiopter) over 95 percent of the glass surface.

Maximum bow and warp 1/32 inch per lineal foot (0.79 mm).

Tempered architectural safety glass shall conform with ANSI Z97.1 and CPSC 16 CFR 1201.

For fully tempered glass, provide heat soak testing conforming to EN14179 which includes a 2 hour dwell at 554 degrees F, plus or minus 18 degrees F (290 degrees C, plus or minus 10 degrees C).

** NOTE TO SPECIFIER ** Delete if not required.

Insulating Glass:

Shall comply with ASTM E 2190 Standard Specification for Insulating Glass Unit Performance and Evaluation.

Units shall be certified for compliance by the IGCC in accordance with the above ASTM test method.

Unit Overall Thickness Tolerance: Minus 1/16 inch (1.6 mm) to 1/32 inch (0.8 mm) for a 1 inch (25 mm) two ply insulating unit. Unit constructed with patterned or laminated glass shall be plus or minus 1/16 inch (1.6 mm).

Shall comply with ASTM E 546 Standard Test Method for Frost Point of Sealed Insulating Glass Units

Shall comply with ASTM E 576 Standard Test Method for Frost Point of Sealed Insulating Glass Units in the Vertical Position

Sealed Insulating Glass Units to be double sealed with a primary seal of polyisobutylene or VTS and a secondary seal of silicone.

The minimum thickness of the secondary seal shall be 1/16 inch (1.6 mm) for metal spacers and 5/32 inch (4 mm) for VTS.

The target width of the primary polyisobutylene seal shall be 5/32 inch (4 mm) and the target width of VTS shall be 1/4 inch (6 mm).

There shall be no voids or skips in the primary seal.

Up to a maximum of 3/32 inch (2.4 mm) of the spacer may be visible above the primary polyisobutylene sealant.

Gaps or skips between primary and secondary sealant are permitted to a maximum width of 1/16 inch (1.6 mm) by maximum length of 2 inches (51 mm) with gaps separated by at least 18 inches (457 mm) and a maximum width of 1/16 inch (1.6 mm) by maximum length of 6 inches (152 mm) along the VTS splice. Continuous contact between the primary seal and the secondary seal is desired.

To provide a hermetically sealed and dehydrated space, lites shall be separated by a boxed spacer with bent corners and straight butyl injected zinc plated steel straight key joints or an extruded VTS thermal plastic spacer.

** NOTE TO SPECIFIER ** Delete if not required.

Laminated Glass:

Shall comply with ASTM 1172 Standard Specification for Laminated Architectural Flat Glass.

All laminated architectural safety glass shall conform with ANSI Z97.1 and CPSC 16 CFR 1201.

Laminated Glass products to be fabricated free of foreign substances and air or glass pockets in autoclave with heat plus pressure.

** NOTE TO SPECIFIER ** Delete if not required.

Sputter-Coated Vision Glass:

Shall comply with ASTM C 1376 Standard for Pyrolytic and Vacuum Deposition Coatings on Glass.

Coated products to be magnetically sputtered vacuum deposition (MSVD)

Edge Deletion - When low-e coatings are used within an insulating unit, coating shall be edge deleted to completely seal the coating within the unit.

The edge deletion should be uniform in appearance (visually straight) and remove 95 percent of the coating.

** NOTE TO SPECIFIER ** Delete if not required.

Ceramic Coated Glass:

Shall comply with ASTM C 1048 Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated, Condition B.

Silk-screen pattern should be no more than 0.0625 inch (1.588 mm) off parallel from locating glass edge and no more than 0.125 inch (3.18 mm) from edges other than locating glass edge.

Silk-screen pattern shall have a maximum of a 0.0313 inch (0.795 mm) variation in dot, hole or line location.

Digital print should be no more than 1/16 inch (1.6 mm) off parallel from locating glass edge and no more than 1/8 inch (3 mm) from edges other than locating glass edge.

Digital print shall have a maximum of a 1/32 inch (0.8 mm) variation in dot, hole or line location.

Digital print may have an indefinite boarder of up to 1/32 inch (0.8 mm).

ACCESSORlES

Glazing Materials: Select glazing sealants, tapes, gaskets and additional glazing materials of proven compatibility with other materials they will contact, including glass products, seals of insulating glass units and glazing channel substrates, under conditions of installation and service, as demonstrated by testing and field experience.

Setting blocks to be 100 percent silicone with a durometer hardness of 85 plus or minus 5.

** NOTE TO SPECIFIER ** If multiple glass types for a glass construction are required, repeat the glass construction by copy and paste, select the glass and accessories for each glass type and identify with label coordinated with drawings.

PRODUCT SCHEDULE

General: All products shall comply with ASTM Standards and requirements in previous sections.

** NOTE TO SPECIFIER ** Delete if not required.

Insulating Coated Glass:

** NOTE TO SPECIFIER ** Select construction requirements for glass types selected. Identify glass types and provide performance for each.

Insulating Coated Glass as manufactured by Viracon.

** NOTE TO SPECIFIER ** Delete exterior glass plys not required.

Exterior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Green (2).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Gray (3).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Bronze (4).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Blue-Green (6).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Azuria (7).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiblue (18).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalGray (19).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Solarblue (26).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Pacifica (27).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optigray (30).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalBlue (32).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Majestic Grey (33).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

** NOTE TO SPECIFIER ** Delete coating options not required.

Coating: VE-85.

Coating: VE-2M.

Coating: VE-48.

Coating: VE-45.

Coating: VE-42.

Coating: VNE-63.

Coating: VNE-53.

Coating: VRE-65.

Coating: VRE-59.

Coating: VRE-54.

Coating: VRE-46.

Coating: VRE-43.

Coating: VRE-38.

Coating: VUE-50.

Coating: VUE-40.

Coating: VUE-30.

Coating: VS-08.

Coating: VS-14.

Coating: VS-20.

Coating: VP-13.

Coating: VP-18.

Coating: VP-22.

Coating: VZRE-65.

Coating: VZRE-59.

Coating: VZRE-54.

Coating: VZRE-46.

Coating: VZRE-38.

Coating: VZE-48.

Coating: VZE-42 on No. 2 Surface.

** NOTE TO SPECIFIER ** Select one, delete the rest of spacer options.

Spacer: 1/2 inch (13.2 mm) Aluminum - mill finish - air filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - mill finish - argon filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - black - air filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - black - argon filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - mill finish - air filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - mill finish - argon filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - black - air filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - black - argon filled.

Spacer: 1/2 inch (13.2 mm) VTS - black - argon filled.

** NOTE TO SPECIFIER ** Select one, delete the rest of silicone color options.

Silicone: Black.

Silicone: Gray.

** NOTE TO SPECIFIER ** Delete interior glass ply options not required. Delete heat treatment not required.

Interior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Clear Roomside Low-E No. 4.

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Performance Requirements:

** NOTE TO SPECIFIER ** Delete options not required.

Visible Light Transmittance: ______ percent.

Visible Light Transmittance: As indicated on the drawings.

Exterior Reflectance: ______ percent.

Exterior Reflectance: As indicated on the drawings.

Winter U-Value: ______.

Winter U-Value: As indicated on the drawings.

Summer U-Value: ______.

Summer U-Value: As indicated on the drawings.

Shading Coefficient: ______.

Shading Coefficient: As indicated on the drawings.

Solar Heat Gain Coefficient: ______.

Solar Heat Gain Coefficient: As indicated on the drawings.

Light to Solar Gain Ratio: ______.

Light to Solar Gain Ratio: As indicated on the drawings.

** NOTE TO SPECIFIER ** Delete if not required.

Laminated Coated Glass:

** NOTE TO SPECIFIER ** Select construction requirements for glass types selected. Identify glass types and provide performance for each.

Laminated Coated Glass as manufactured by Viracon.

** NOTE TO SPECIFIER ** Delete exterior glass plys not required.

Exterior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Green (2).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Gray (3).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Bronze (4).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Blue-Green (6).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Azuria (7).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiblue (18).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalGray (19).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Solarblue (26).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Pacifica (27).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optigray (30).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalBlue (32).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Majestic Grey (33).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

** NOTE TO SPECIFIER ** Delete coating options not required.

Coating: VE-85.

Coating: VLE-70.

Coating: VE-48.

Coating: VE-42.

Coating: VLE-57.

Coating: VLE-51.

Coating: VLE-47.

Coating: VLE-39.

Coating: VS-08.

Coating: VS-14.

Coating: VS-20.

Coating: VP-13.

Coating: VP-18.

Coating: VP-22 on No. 2 Surface.

Interlayer: 0.060 inch (1.52 mm) Clear PVB.

** NOTE TO SPECIFIER ** Delete interior glass ply options not required. Delete heat treatment not required.

Interior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply: 1/4 inch (6 mm) Clear Roomside Low-E No. 4.

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Performance Requirements:

** NOTE TO SPECIFIER ** Delete options not required.

Visible Light Transmittance: ______ percent.

Visible Light Transmittance: As indicated on the drawings.

Exterior Reflectance: ______ percent.

Exterior Reflectance: As indicated on the drawings.

Winter U-Value: ______.

Winter U-Value: As indicated on the drawings.

Summer U-Value: ______.

Summer U-Value: As indicated on the drawings.

Shading Coefficient: ______.

Shading Coefficient: As indicated on the drawings.

Solar Heat Gain Coefficient: ______.

Solar Heat Gain Coefficient: As indicated on the drawings.

Light to Solar Gain Ratio: ______.

Light to Solar Gain Ratio: As indicated on the drawings.

** NOTE TO SPECIFIER ** Delete if not required.

Monolithic Reflective Glass:

** NOTE TO SPECIFIER ** Select construction requirements for glass types selected. Identify glass types and provide performance for each.

Monolithic Reflective Glass as manufactured by Viracon.

** NOTE TO SPECIFIER ** Delete exterior glass plys not required.

Exterior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Green (2).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Gray (3).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Bronze (4).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Blue-Green (6).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Azuria (7).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiblue (18).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalGray (19).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Solarblue (26).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Pacifica (27).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optigray (30).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalBlue (32).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Majestic Grey (33).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

** NOTE TO SPECIFIER ** Delete coating options not required.

Coating: VS-08.

Coating: VS-14.

Coating: VS-20.

Coating: VP-13.

Coating: VP-18.

Coating: VP-22 on No. 2 Surface.

Performance Requirements:

** NOTE TO SPECIFIER ** Delete options not required.

Visible Light Transmittance: ______ percent.

Visible Light Transmittance: As indicated on the drawings.

Exterior Reflectance: ______ percent.

Exterior Reflectance: As indicated on the drawings.

Winter U-Value: ______.

Winter U-Value: As indicated on the drawings.

Summer U-Value: ______.

Summer U-Value: As indicated on the drawings.

Shading Coefficient: ______.

Shading Coefficient: As indicated on the drawings.

Solar Heat Gain Coefficient: ______.

Solar Heat Gain Coefficient: As indicated on the drawings.

Light to Solar Gain Ratio: ______.

Light to Solar Gain Ratio: As indicated on the drawings.

** NOTE TO SPECIFIER ** Delete if not required.

Insulating Laminated Coated Glass:

** NOTE TO SPECIFIER ** Select construction requirements for glass types selected. Identify glass types and provide performance for each.

Insulating Laminated Coated Glass as manufactured by Viracon.

** NOTE TO SPECIFIER ** Delete exterior glass plys not required.

Exterior Glass Ply: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Green (2).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Gray (3).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Bronze (4).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Blue-Green (6).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Azuria (7).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiblue (18).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalGray (19).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Solarblue (26).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Pacifica (27).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Optigray (30).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) CrystalBlue (32).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Majestic Grey (33).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Exterior Glass Ply: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

** NOTE TO SPECIFIER ** Delete coating options not required.

Coating: VE-85.

Coating: VE-2M.

Coating: VE-48.

Coating: VE-45.

Coating: VE-42.

Coating: VNE-63.

Coating: VNE-53.

Coating: VRE-65.

Coating: VRE-59.

Coating: VRE-54.

Coating: VRE-46.

Coating: VRE-43.

Coating: VRE-38.

Coating: VUE-50.

Coating: VUE-40.

Coating: VUE-30.

Coating: VS-08.

Coating: VS-14.

Coating: VS-20.

Coating: VP-13.

Coating: VP-18.

Coating: VP-22.

Coating: VZRE-65.

Coating: VZRE-59.

Coating: VZRE-54.

Coating: VZRE-46.

Coating: VZRE-38.

Coating: VZE-48

Coating: VZE-42 on No. 2 Surface.

** NOTE TO SPECIFIER ** Select one, delete the rest of spacer options.

Spacer: 1/2 inch (13.2 mm) Aluminum - mill finish - air filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - mill finish - argon filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - black - air filled.

Spacer: 1/2 inch (13.2 mm) Aluminum - black - argon filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - mill finish - air filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - mill finish - argon filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - black - air filled.

Spacer: 1/2 inch (13.2 mm) Stainless Steel - black - argon filled.

Spacer: 1/2 inch (13.2 mm) VTS - black - argon filled.

** NOTE TO SPECIFIER ** Select one, delete the rest of silicone color options.

Silicone: Black.

Silicone: Gray.

** NOTE TO SPECIFIER ** Delete interior glass ply options (1) not required. Delete heat treatment not required.

Interior Glass Ply 1: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 1: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 1: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 1: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interlayer: 0.060 inch (1.52 mm) Clear PVB.

** NOTE TO SPECIFIER ** Delete interior glass ply options (2) not required. Delete heat treatment not required.

Interior Glass Ply 2: 1/4 inch (6 mm) Clear (1).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 2: 1/4 inch (6 mm) Starphire (13).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 2: 1/4 inch (6 mm) Optiwhite (24).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 2: 1/4 inch (6 mm) Acuity (34).

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Interior Glass Ply 2: 1/4 inch (6 mm) Clear Roomside Low-E No. 4.

Heat Treatment: AN.

Heat Treatment: HS.

Heat treatment: FT.

Heat Treatment: FT Heat Soak.

Performance Requirements:

** NOTE TO SPECIFIER ** Delete options not required.

Visible Light Transmittance: ______ percent.

Visible Light Transmittance: As indicated on the drawings.

Exterior Reflectance: ______ percent.

Exterior Reflectance: As indicated on the drawings.

Winter U-Value: ______.

Winter U-Value: As indicated on the drawings.

Summer U-Value: ______.

Summer U-Value: As indicated on the drawings.

Shading Coefficient: ______.

Shading Coefficient: As indicated on the drawings.

Solar Heat Gain Coefficient: ______.

Solar Heat Gain Coefficient: As indicated on the drawings.

Light to Solar Gain Ratio: ______.

Light to Solar Gain Ratio: As indicated on the drawings.

EXECUTION

EXAMINATION

Verification of Conditions:

Verify prepared openings for glazing are correctly sized and within tolerance. Verify that the minimum required face and edge clearances are being followed.

Verify that a functioning weep system is present.

Do not proceed with glazing until unsatisfactory conditions have been corrected.

PREPARATION

Surface Preparation: Immediately before glazing, clean glazing channels and other framing members receiving glass. Remove coatings not firmly bonded to substrates.

Demolition and Removal: Remove and replace glass that is broken, chipped, cracked or damaged in any way.

INSTALLATION

Install products using the recommendations of manufacturers of glass, sealants, gaskets and other glazing materials including those in the GANA Glazing Manual except where more stringent requirements are indicated.

Prevent glass from contact with contaminating substances that result from construction operations such as weld splatter, fire-safing or plastering.

CLEANING

Clean excess sealant or compound from glass and framing members immediately after application using solvents or cleaners recommended by manufacturers.

END OF SECTION ................
................