TRICON Systems Inc.
Car controller specification
Foreword
Document revision date: 06/01/10
Please fill all ten pages completely. It is very important to include ALL information to assure an accurate price quote and controller configuration. The standard indicator voltages are 24VDC or 110VDC, high side outputs.
Note: Cars having different speed, capacity, motor data or openings require separate data sheets.
Note: CE Micro Com driver supplied by MCE for Tricon will operate a maximum of four displays. If five or more displays are used, Heavy Duty CE provisions are required at additional charge. If you are providing a digital display driver, the inputs will be +24VDC, binary starting with one at the bottom floor.
General data Elevator Safety Code Compliance
Date:
Customer
|Company Name: |
|Contact / Survey by: |
|Phone: Fax: |
|Approval Signature: Date: |
Job
|Job name | |
|Job address | |
|Car name | |
|Delivery date | |
Shipping Address
Controller to be picked up at MCE Yes No
Shipping address same as your office Yes No
|Company Name: |
|Ship Address: |
| |
|Phone / Contact: |
|Lift Gate Required Yes No |
|Flat bed Truck Required Yes No |
|Notice Required 24-Hr 48-Hr Other |
Specification
| Not provided Yes, Number of pages: |
|Consultant Company: |
|Name: |
|Phone: Fax: |
Elevator type
Passenger Simplex Simplex W/ Emg Power
Service Freight Car Switch
Group car w/Sep dispatcher box
Car speed: Fpm Load Capacity: Lbs
Note: All multi car groups and simplex cars with emergency power or Hospital Code Blue require a separate dispatcher box.
|Project Type: New construction Modernization |
|Measurements: U.S./English S.I./Metric |
| |
|Compliance |
| ASME A17.1-2007 A17.1-2004 A17.1-2000 |
| ASME A17.1-1996/98 (If 98 addendum on multi-car installation, provide |
|details on machine room/hoistway configuration page 6 or on a separate sheet |
|of paper.) |
| ASME A17.1- Specify code and addenda. |
| |
|International compliance |
| Canada B44-07 B44-04 B44-00 |
| Other: |
Power line
Note: The following voltages are 60 HZ 3 phase
208 VAC 220 VAC 440 VAC
460 VAC 480 VAC 575 VAC
220 VAC 60 Hz single phase 600 VAC
Other: 240 VAC
Control type
VV-MG (Fill page 7)
VVVF open loop (Fill page 3)
VVVF/VFD closed loop (Fill page 3)
VV-SCR control (Fill page 3)
Hydraulic (Fill page 3)
Control options
Cabinet door hinge mounting (circle one):
Car #: Car #:
[pic]
|Pre-wired car station (serial link) | No Yes |
|Remote car top box (serial link) | No Yes |
|Cabinet legs 18” (HPV600, Hydro only) | No Yes |
|Cabinet Stands 4”(HPV900,SCR,MG) |No Yes |
|Air Conditioning | No Yes |
|Hand held units | No Yes, quantity _____ |
Note: A Tricon pre wired car station w/ I/O boards installed requires the remote car top box option. The car station must be shipped to MCE for wiring. Remote car top box only is acceptable.
Riser description (NO SHORT FLOORS ALLOWED)
| | | |OPENINGS |SIMPLEX HALL CALLS / IR |GROUP HALL CALLS |LOCKOUTS |
|Floor |Floor |
| |height |
|Floor marking: |The floor identification in the building |
|Front opening: |The car has a front door at the floor. |
|Local hall up: |The car is simplex and has a hall up call or has a hall independent riser up call at the floor. |
|Local hall down: |The car is simplex and has a hall down call or has a hall independent riser down call at the floor. |
|Rear opening: |The car has a rear door at the floor. |
|Local rear hall up: |The car is simplex and has a rear door hall up call or has a hall independent riser rear up call at the floor. |
|Local rear hall down: |The car is simplex and has a rear door hall down call or has a hall independent riser rear down call at the floor. |
Shaft data
Total shaft height Car #1 feet Car #2 feet
Selector tape length Car #1 feet Car #2 feet
Selector tape length should be the total shaft height, from the pit floor to the motor room floor.
Lobby signals and devices
Lobby Position Indicator
None
Lamps
110 VDC 24 VDC
Dir. Arrows Yes No
CE MicroCom® driver (provided by MCE)
CE MicroCom® driver (provided by customer)
E-Motive driver (provided by MCE)
Hall signals and devices
Hall Indicators
Position Indicators, (Other than lobby)
None
CE Display (Max. 4 displays)
CE Display Heavy Duty (5 or more displays) Add.chg.
Analog lamps (Max. 3 lamps)
Analog lampsHeavy Duty(4 or more lamps) Add.chg.
110 VDC 24 VDC
Dir. Arrows: Yes No
CE MicroCom driver (provided by MCE)
CE MicroCom driver (provided by customer)
E-Motive driver (provided by MCE)
Other, specify: ________________________
In-use light
No Yes
If Yes, voltage 110 VDC 24 VDC
Hall Direction Arrows (Other than Pos. Ind.)
No Yes
If Yes, voltage 110 VDC 24 VDC
Hall Lanterns
None Yes
If Yes, voltage 110 VDC 24 VDC
Hall Call Pushbuttons
Car switch operation with hall calls and in car annunciation
Switch type, no Ack. light
Switch type, Ack. Lights
110 VDC 24 VDC
Car station signals and devices
Car call pushbuttons
Switch type, no Ack. lights
Switch type, Ack. Lights
110 VDC 24 VDC
Car station position indicator
None
Lamps
110 VDC 24 VDC
Dir. Arrows: Yes No
CE MicroCom driver (provided by MCE)
CE MicroCom driver (provided by customer)
E-Motive driver (provided by MCE)
Other, specify __________________________
Attendant in Car Annunciators
No Yes
Audible signal (Buzzer only) 110 VDC 24 VDC
Visual signal (Panel in car or hall to indicate hall calls)
NOTE: Provided only with car switch operation.
If Yes, voltage 110 VDC 24 VDC
Auxiliary Car Station
No Yes
Buzzers
Fire buzzer
None
110 VDC 24 VDC
Nudging buzzer
None Use fire buzzer
110 VDC 24 VDC
Passing chime
None Use fire buzzer
110 VDC 24 VDC
Other switches
Car insp. sw. (required for access) Yes No
Attendant up-down buttons Yes No
Attendant direction arrows Yes No
Attendant bypass button Yes No
“S” Handicap Chime Enable Button Yes No
Car Call Lockouts Yes No
Which Floors
Car Call Lockout Type
Key switch Cardreader
Car Call Lockout Location
Car Station Remote
NOTE: All lockout key switches located in car station
sent to MCE for pre-wiring will be wired in car station to car buttons unless otherwise stated. Remote locks will be wired to input card on controller.
Car signals and devices, other than car station
Car position indicator (In transom)
None
Lamps
110 VDC 24 VDC
Dir. Arrows: Yes No
CE MicroCom® driver (provided by MCE)
CE MicroCom® driver (provided by customer)
E-Motive driver (provided by MCE)
Other, specify
Car arrival lanterns and gong
None
Lamps
110 VDC 24 VDC
Front Door
Car door type
Manual door Master door Freight
Manufacturer
Model
Door operator
None New Existing
SmarTraq Complete DO SmarTraq Upgrade Kit
GAL MODCT GAL MOMCT
GAL MOD (230V shunt) GAL MODP(swing)
GAL MODPM GAL MOMSVL
GAL MOVFR GAL MOM / MOH
MAC / ECI (Electronic) Moline (Resistor)
Schindler QKS-14or15 Courion
Peelle (Auto open) Peelle (Auto O and C)
Other EMS
Manufacturer
Model
Include door operator prints
Note: Supply prints for all freight operators.
Note: Tricon standard for GAL MOCT type operators is 208VAC supply and 110 VDC relays
Door Detector interface
Standard (detectors which close dry contact)
Other, describe
Hall doors type
Manual
Driven by car door (automatic)
Swing door with 2 circuit locks
Freight door
Manufacturer
Model
Door retiring cam
None New Existing
Mechanical
Electrical
Two circuit door locks No Yes
GAL 220 VAC
Other, volts
Motor Coil
Pick volts Resistance ohms
Rear Door
Car door type
Manual door Master door Freight
Manufacturer
Model
Door operator
None New Existing
SmarTraq Complete DO SmarTraq Upgrade Kit
GAL MODCT GAL MOMCT
GAL MOD (230V shunt) GAL MODP(swing)
GAL MODPM GAL MOMSVL
GAL MOVFR
110VAC 220VAC (220 is default if no selection made)
GAL MOM / MOH
MAC / ECI (Electronic) Moline (Resistor)
Schindler QKS-14or15 Courion
Peelle (Auto open) Peelle (Auto O and C)
Other EMS
Manufacturer
Model
Include door operator prints
Note: Supply prints for all freight operators.
Note: Tricon standard for GAL MOCT type operators is 208VAC supply and 110 VDC relays
Door Detector interface
Standard (detectors which close dry contact)
Other, describe
Hall doors type
Manual
Driven by car door (automatic)
Swing door with 2 circuit locks
Freight door
Manufacturer
Model
Door retiring cam
None New Existing
Mechanical
Electrical
Two circuit door locks No Yes
GAL 220 VAC
Other, volts
Motor Coil
Pick volts Resistance ohms
Car special operations
Fireman’s operation
No Yes
ANSI 17.1 Version -
NYC operation
“Master Fire Service” switch (Chicago only)
Other (Please describe)
_______________________________________
_______________________________________
_______________________________________
_______________________________________
Fire recall floor ______ Rear door
Smoke detectors
No Yes
Alternate recall floor Rear door
Smoke bypass switch Yes No
Hoistway Access switch
Top floor
Yes None
Bottom floor
Yes None
Other floor
____ None
Note: An inspection switch in the car is required, as well as hoistway limit switches.
Special services
Attendant No Yes
Independent service No Yes
Inconspicuous Riser(IR) Car# No Yes
Earthquake No Yes
Cross Cancel No Yes
Lobby recall No Yes
Floor Rear door
Load Weigh unit (K- Tech) No Yes
Emg Power (Disp required) No Yes
Color Lobby Display No Yes
Master Control Key Sw. for schools No Yes
Sabbath Feature No Yes
Hosp. Code Blue (Disp. required) No Yes
Rope Gripper (GAL) No Yes
Monitoring Systems
Lift-Net
O. Thompson CLD
(Display up to two groups/simplexes)
List all cars in all groups/simplexes to be displayed/monitored:
____________________________________________
____________________________________________
____________________________________________
____________________________________________
Monitor Options: 17” LCD Other:
Printer (Lift-Net only)
Number of machine-room and lobby monitoring stations:
0 1 Other: (Lift_Net only)
Machine room or lobby monitoring station connectivity:
Line Drivers
Cat 5 (line driver replacement only; not connected to
building LAN; Lift-Net only)
Cat 5, connected to building LAN (Lift-Net only)
If connected to building LAN, provide static IP
addresses for all monitoring stations and all
monitored group/simplex controllers (see NOTE)
_________________________________________
_________________________________________
_________________________________________
Number of remote location monitoring stations (Lift-Net only):
0
Other (At least one machine room or lobby monitoring
station must be selected above). Number:
Approx distance between remote monitoring stations
and controllers:
Remote location monitoring station connectivity (Lift-Net only):
Dedicated dial-up lines.
Phone numbers: ____________________________
__________________________________________
WAN
Static IP addresses for all monitoring stations
(machine room, lobby, remote location) and all
monitored group/simplex controllers (see NOTE)
___________________________________________
___________________________________________
NOTE: MCE is not responsible for required parts and/or labor external to the monitoring system, controllers, and PC-controller interface, such as routers, cable modems, or field wiring to enable communications using the specific IP addresses provided by the customer.
VV-MG control
Machine
New Re-use existing Location
Geared Overhead
Gearless Basement
Drum
Other
Manufacturer
Model
Brake
New Re-use existing
Manufacturer
Model
AC DC
Specify either voltage or current; no need to specify both.
Lift volts amps
Hold volts amps
Relevel volts amps
Resistance ohms
DC Hoist Motor
New Re-use existing
Manufacturer
Model
Frame
Type
Amps:
Nom. Volts
H.P.
RPM
Hoist motor shunt field
Specify either voltage or current; no need to specify both.
Standing volts amps
Full field volts amps
Running volts amps
Resistance ohms
Note: All complete motor & brake info must be provided to avoid delays in processing.
DC Motor Generator
New Re-use existing
Manufacturer
Generator Driving Motor
Manufacturer
Model
Frame
Type
Amps:
Nom. Volts AC DC
H.P.
RPM
Starter
Across the line Wye-delta
Other, describe _____________________
Generator Data
Manufacturer
Model
Frame
Type
K.W.
Voltage volts
Current amps
Generator Shunt Field
Running data volts amps
Resistance ohms
DC Tachometer
Provided by MCE, DC Tachometer, and coupling
Base mount Flange mount
Select a coupling below if MCE is providing the tach
5/16 X ¼ 5/16 X 5/16 5/16 X 3/8
5/16 X 7/16 5/16 X 1/2
(Default diameter = 1/4”)
Provided by motor manuf. when installing a new motor
Note: The tach provided by the motor manufacturer should be 100VDC per 1000RPM. The motor manufacturer should provide the mounting and couplings. The tach provided by MCE includes tach, coupling.
Note: All complete motor & brake info must be provided to avoid delays in processing.
SCR control
Machine
New Re-use existing Location
Geared Overhead
Gear-less Basement
Drum
Other
Manufacturer
Model
Brake
New Re-use existing
Manufacturer
Model
AC DC
Specify either voltage or current; no need to specify both.
Lift volts amps
Hold volts amps
Relevel volts amps
Resistance ohms
Model
DC Hoist Motor
New Re-use existing
Manufacturer
Model
Frame
Type
Amps:
Nom. Volts
H.P.
RPM
Drive
Provide choke Yes No
Encoder Tachometer
Provided by MCE, encoder, coupling and cable
Select a coupling below if MCE is providing the encoder
3/8 X ¼ 3/8 X 3/8 3/8 X 7/16
3/8 X 1/2
(Default diameter = 1/4”)
Provided by motor manuf. when installing a new motor
Note: The encoder provided by the motor manufacturer should be 5VDC differential 150MA, 2 channel quadrature, (A, A not, B, B not). The motor manufacturer should provide the mounting, couplings, and cable. The encoder provided by MCE includes encoder, coupling and cable.
Note: All complete motor & brake info must be provided to avoid delays in processing.
Isolation Transformers & Chokes shipped to customer directly from manufacturer:
Yes No
Isolation Transformers & Chokes:
Stackable Non-Stackable
Hoist motor shunt field
Specify either voltage or current, no need to specify both.
Standing volts amps
Full field volts amps
Running volts amps
Resistance ohms
VVVF / VFD Control
Machine
New Re-use existing Location
Geared Overhead
Gear-less Basement
Drum
Other
Manufacturer
Model
Brake
New Re-use existing
Manufacturer
Model
AC DC
Specify either voltage or current; no need to specify both.
Lift volts amps
Hold volts amps
Resistance ohms
Hoist motor
New Re-use existing
Manufacturer
Model
Amps:
Nom. Volts
H.P.
RPM
NOTE:
Only when using HPV600 drive at 100FPM
with remote car top box and floors in line Tricon can provide slowdown magnets on the leveling unit (IP9600) to eliminate the
need to mount mechanical switches in the
hatch.
IP9600 w/slowdowns SET9000
Drive
Open loop configuration (no encoder)
Closed loop configuration
(cable, encoder and coupling may be provided, see the encoder selection box below)
Encoder Tachometer
Provided by MCE, encoder, coupling and cable
Select a coupling below if MCE is providing the encoder
3/8 X 5/16 3/8 X 3/8 3/8 X 7/16
3/8 X ½ 3/8 X ¼
(Default diameter = 1/4”)
Provided by motor manuf. when installing a new motor
Note: The encoder provided by the motor manufacturer should be 5VDC differential 150MA, 2 channel quadrature, (A, A not, B, B not). The motor manufacturer should provide the mounting, couplings, and cable. The encoder provided by MCE includes encoder, coupling and cable.
Note: All complete motor & brake info must be provided to avoid delays in processing.
Hydraulic control
Pump Motor
New Re-use existing
Manufacturer
Model
Frame
Type
Amps:
Nom. Volts
H.P.
RPM
Tandem pumps
No Yes
If Yes, how many
Tandem Valves
No Yes
If yes, provide a description of the desired pump starting and valve sequence.
Valve
New Re-use existing
Manufacturer
Model
Coils voltage volts AC DC
Number of coils
Sequence:
Up fast
Up slow
Down fast
Down slow
Note: Tricon provides a standard valve sequence. Both valves, fast and slow are energized in high speed. When the car slows down, high speed is dropped, and the slow speed valve remains energized, until the car levels to the floor.
Starter
Starters provided by Tricon (select one below)
ATL Wye-Delta (see Note 2 below)
Soft Starter (see Note 1 below)
3 Wire Motor 6 Wire Motor
Note 1: Separate Enclosure provided for all Soft Starters. Contact MCE Engineering for details.
Note 2: Separate starter enclosures are required for larger starter sizes. Contact MCE Engineering for details.
If re-using existing indicate which:
ATL Wye-delta
Soft-starter Manufacturer
Note: If re-using existing, may require rewiring to Tricon standard interface.
(Provide prints for existing starter or Softstarter)
Other
Rescuvator interface type:
GAL Reynolds & Reynolds
Low pressure switch
High temperature switch
................
................