CFT Series .windows.net
CFT Series
CABINET FAN
Cabinet Fan - CFT Series
Cabinet is manufactured in galvanized sheet steel incorporated with a belt driven, high efficiency, double inlet
forward curve, backward curve or airfoil wheel.
Complete with inlet & outlet flange as standard.
Motor and drive assembly can be accessed through removal of two side panels.
Internal vibration isolator to assure long life and quiet operation.
Penta Post construction with ABS plastic corner piece, aluminum column and reinforced galvanized sheet panel
Acoustic lining is available upon request. Standard acoustic lining employs galvanized sheet facing
Perforated sheet facing is available upon request.
Type of fan use: CFT 200 to CFT 710 ---- FDA/BDB/ADA `C' type
CFT 800 to CFT 1000 ---- FDA/BDB/ADA `T' type
Kruger Ventilation Industries Asia Co., Ltd certifies that the CFT 315-1000 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
Dimension
90?Orientation
C
30
A
30
F
=
D
H
K B
E
M J
360?Orientation
C E
=
L
30 P
A
D
N
G
?19
=
H
K B
=
G
?19
M
L
J
Model
A
B
C
D
E
F
G
H
J
K
L
M N
CFT200 880 589 662 256 256 106 472 399 962 40 580 862 190 CFT225 960 635 734 288 288 106 544 445 1034 40 660 934 204 CFT250 1000 679 810 322 322 106 620 489 1210 40 700 1110 214 CFT280 1120 736 900 360 360 106 710 546 1300 40 770 1200 232 CFT315 1200 798 1000 404 404 106 810 608 1400 40 850 1300 261 CFT355 1300 871 1109 452 452 106 919 681 1509 40 950 1409 286 CFT400 1400 954 1234 506 506 106 1044 764 1634 40 1050 1534 315 CFT450 1500 1055 1371 568 568 106 1181 865 1771 40 1100 1671 344 CFT500 1600 1175 1568 638 638 123 1348 955 1968 50 1200 1868 365 CFT560 1700 1285 1742 714 714 123 1522 1065 2142 50 1300 2042 399 CFT630 1900 1410 1940 800 800 123 1720 1190 2340 50 1350 2240 441 CFT710 2100 1584 2164 898 898 123 1944 1364 2664 100 1400 2564 487 CFT800 2300 1750 2413 1006 1006 123 2193 1530 2913 100 1600 2813 545 CFT900 2530 1930 2681 1130 1130 123 2461 1710 3181 125 1830 3081 601 CFT1000 2700 2090 3000 1266 1266 123 2780 1870 3500 150 1900 3400 625 * Weight without fan, motor and drive transmission. * Please consult KRUGER for details when motor frame size is beyond this range,
All Dimension in mm.
Weight* Max. Motor*
P
(kg) Frame Size
434
49
100L
468
55
112M
464
61
112M
528
67
132S
535
81
132M
562
93
132M
579
110
160M
588
129
160M
597
146
160L
587
154
160L
659
187
180M
715
249
180L
749
290
200L
799
335
225S
809
389
225M
Ps (Pa) 1800
FEG 80
92
1500 90
89
CFT 315 B
RPM kW
1200 86
85
83
900 81
94
80
90
77
600
76
87
72 72
84 80
300 66
66
76
70
0
75 81 85 89 92
0.0
0.5
1.0
1.5
2.0
2.5
82 98 3.0
3.5 Q (m3/s)
V (m/s)
0
5
10
15
20
Performance Curve ? CFT - B
Ps (Pa) FEG 80
1800
91 1500
87 1200
85
88 85
CFT 355 B
RPM kW
83 900
80 93
79
600
76
75
90 87
84 70
69
300
80
74
0
79
85
89
92 95
97
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q (m3/s)
0
5
10
15
V (m/s)
Ps (Pa) FEG 80
1800 92
1500
90
CFT 400 B
RPM kW
88
1200
87 85
84
82
900
94
82
79
79
600
75
91 88
75
86
71
71
83
300
79
75
0
80 84 88 91 93 96
81
0
1
2
3
4
5 Q (m3/s)
0
5
10
15
V (m/s)
Ps (Pa) 1800
FEG 80
92
1500
90 90
CFT 450 B
RPM kW
1200 900 600 300 0 0
88
87
85 84
83 80
94 92
79
75
89
75
70 70
87 83
78
74
79 84 88 91 94 97 81
1
2
3
4
5
6
` 7 Q (m3/s)
V (m/s)
0
5
10
15
20
Ps (Pa) FEG 80
1800 92
1500
89 1200
85
90 88
CFT 500 B
RPM kW
900 600
300 0 0
81 76 71
85 80
94 91
76
89
84 71
80 75
80 85 89 93
1
2
3
4
5
6
96 99
7
8 Q (m3/s)
0
5
10
15
V (m/s)
Ps (Pa) 1800
FEG 80
92
1500
91
CFT 560 B
RPM kW
89
1200 900 600 300 0 0
88 84
84 80
79
95 92
75
87
74
68
83
68
78
71
77
84 89
93 97 100
1 2 3 4 5 6 7 8 9 10
11 Q (m3/s)
V (m/s)
0
5
10
15
20
- Performance certified is for installation type D ? ducted inlet, ducted outlet. - Performance ratings do not include the effects of appurtenances (accessories).
Power rating kW does not include transmission losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for
installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. -The AMCA Certified Ratings Seal applies to air performance rating only.
Performance Curve ? CFT - B
Ps (Pa) FEG 80
1600 121
1400 89
1200
87
1000
92 90 87
CFT 630 B
RPM kW
83
800
83
96 94
600
77
78
92
400
71
72
87 82
200
76
82
88
93
97 100 101
0
0
2
4
6
8
10
12
14 Q (m3/s)
V (m/s)
0
5
10
15
20
Ps (Pa) FEG 80
1800
92 1500
92
CFT 710 B
RPM kW
1200 900 600 300 0 0 0
88 89
86 87
84
84
96
81
82
93
78 74
70
79 75
91 88 86
71
83
79
75
81 85 89 92 94 97 77 102
2
4
6
8 10 12 14 16
5
10
15
20
18 Q (m3/s) V (m/s)
Ps (Pa) FEG 85
1800
1500 1200
900 600 300
92
90 87
92 90 88
84 81 78 74
85
97
94 82
92
79
89
75
86
83
79
CFT 800 B
RPM kW
0 02
0
46 5
85 89 92 95 98 100 77 8 10 12 14 16 18 20 Q (m3/s)
10
15
V (m/s)
Ps (Pa) FEG 85
1800
92 1500
91
93 92
CFT 900 B
RPM kW
1200 900 600 300
89
89
85 82 78
86 83 79
97 96 94
91
73
74
87
83 78
84 89 93 97 99 102 75 0
0
4
8
12
16
20
24
28 Q (m3/s)
V (m/s)
0
5
10
15
20
Ps (Pa) FEG 85
2000
CFT 1000 B
1600
94 89
95 90
RPM kW
1200
800
400
0 0
89 90
85 86
81 82
100
97 94
77 71
78
72
82
76
91 86
82 88 93
97 100 103 75
5
10
15
20
25
30
35 Q (m3/s)
V (m/s)
0
5
10
15
20
- Performance certified is for installation type D ? ducted inlet, ducted outlet. - Performance ratings do not include the effects of appurtenances (accessories).
Power rating kW does not include transmission losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for
installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. -The AMCA Certified Ratings Seal applies to air performance rating only.
Performance Curve ? CFT - A
Ps (Pa) FEG 85
1800 93
1500
90
95
CFT 315 A
RPM kW
1200
87
92
900
83
89
86 80
600 82
75
96
93 90
300 70
77
71 74
87
83 79
0
76 82 86 90 93 80 99
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5 Q (m3/s)
V (m/s)
0
5
10
15
20
Ps (Pa) FEG 80
1800
92 1500
CFT 355 A
RPM kW
1200 900 600 300 0 0.0 0
89
94
87 91
84
89
82
87
96
84
77
93
79
91
88
72
85
73
81
75
78 84 88 91 94 79 0.5 1.0 1.5 2.0 2.5 3.0 3.5
5
10
15
99 4.0 Q (m3/s)
V (m/s)
Ps (Pa) FEG 80
1800 94
1500 90
CFT 400 A
RPM kW 96
1200 900 600 300 0 0 0
88 85
93 90
82 79 73
1
87
97
84 80
74 76
94
92 90 86 82
79 2
85 89 92 95 79
3
4
5
10
15
100 5 Q (m3/s)
V (m/s)
Ps (Pa) FEG 85
1800 95
1500
97 91
CFT 450 A
RPM kW
1200 900 600 300 0 0 0
89
94
91 85
88 83
98
84 79
95
80
92
74
89
76
86
82
77
79 84 88 91 95 78 100
1
2
3
4
5
6
7 Q (m3/s)
V (m/s)
5
10
15
20
Ps (Pa) FEG 80
1800
94 1500
CFT 500 A
RPM kW
1200 900 600 300 0 0 0
91
96
93 87
89 84
86 80
81
76 77
91 87
83 78
97 94
80 85 90 93 97 78
1
2
3
4
5
6
7
8 Q (m3/s)
5
10
15
V (m/s)
Ps (Pa) FEG 85
1800
1500 1200
94
96 91
CFT 560 A
RPM kW
93
87 900
600
300
0 0
89
84
98
85
94
79
80
91
74 74
87
82
76
77 84 89 93 97
2
4
6
8
77 10 Q (m3/s)
0
5
10
15
V (m/s)
- Performance certified is for installation type D ? ducted inlet, ducted outlet. - Performance ratings do not include the effects of appurtenances (accessories).
Power rating kW does not include transmission losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for
installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. -The AMCA Certified Ratings Seal applies to air performance rating only.
................
................