STANDARD DETAILS FOR WATER MAIN INSTALLATIONS - …
[Pages:46]CITY OF CHICAGO
DEPARTMENT OF WATER MANAGEMENT
STANDARD DETAILS FOR
WATER MAIN INSTALLATIONS
PREPARED BY:
BUREAU OF ENGINEERING SERVICES
April, 2009
City of Chicago Richard M. Daley
Mayor
Department of Water Management John F. Spatz, Jr. Commissioner
This page intentionally left blank.
TABLE OF CONTENTS
GENERAL DETAILS
G-1
PROJECT SIGN
G-3
SAMPLE SYBOLOGY LEGEND
G-4 (1 OF 2) LEGEND - SYMBOLS
G-4 (2 OF 2) LEGEND ? LINE STYLES
WATER MAIN DETAILS
D-2
FIRE HYDRANT SETTING DETAIL
D-3
FIRE HYDRANT INSTALLATION DETAIL FOR VAULTED SIDEWALKS
D-5
FIRE HYDRANT DRAIN DETAIL
D-6
FIRE HYDRANT SUMP FOR RELOCATED HYDRANTS
D-7
COLOR CODE FOR FIRE HYDRANTS
D-8
WATER MAIN TRENCH DETAILS
D-9
WATER MAIN TRENCH INSULATION DETAIL
D-10
WATER MAIN POLYETHYLENE WRAP DETAIL
D-11
THRUST RESTRAINT CONCRETE THRUST BLOCK DETAILS
D-12
THRUST RESTRAINT RESTRAINED JOINT PIPE
D-13
PRECAST VALVE BASIN FOR PIPES UP TO 16-INCH DIAMETER
D-14
BRICK MASONRY VALVE BASIN
D-16
TYPICAL 1-INCH TO 2-INCH WATER SERVICE
D-18
CASING PIPE UNDER RAILROAD TRACK DETAIL
D-19 (1 OF 2) WATER MAINS CROSSING OVER SEWERS AND HOUSE DRAINS
D-19 (2 OF 2) WATER MAINS CROSSING UNDER SEWERS AND HOUSE DRAINS
D-20 (1 OF 2) GENERAL NOTES WATER MAIN CONTRACTS
D-20 (2 OF 2) GENERAL NOTES WATER MAIN CONTRACTS ? CON'T
D-23
NEW COPPER 1-INCH WATER SERVICE STANDARD METER VAULT
D-24
NEW COPPER 1.5 N. & 2 IN. WATER SERVICE STANDARD METER VAULT
D-25
3 INCH, 4 INCH, 6 INCH, 8 INCH & 12 INCH METER VAULTS
D-26
12 INCH METER VAULT WITH CHECK VALVE
D-27
TYPICAL METER INSTALLATION FOR 1 INCH WATER SERVICE WITH
LAWN HYDRANT AND BACKFLOW PREVENTOR
D-28
ELECTRICAL CONTINUITY BRACKET FOR TRANSITION COUPLING
D-30
TYPICAL SERVICE RECONNECTION 3 INCH AND LARGER USING MJ
RESILIENT WEDGE VALVE
D-31
SERVICE PIPE INSULATION
1
FEEDER MAIN DETAILS
FM-1
INSPECTION MANHOLE
FM-4
PITOMETER TAP BASIN PRECAST CONCRETE
FM-5
FIRE HYDRANT SETTING 16 INCH & LARGER WATER
FM-13
BUTTERFLY VALVE
FM-14
TORQUE OVERLOAD PROTECTOR
FM-15
BUTTERFLY VALVE BASIN PRECAST CONCRETE
FM-16 (1 OF 2) BUTTERFLY VALVE BASIN ? MASONRY PLAN
FM-16 (2 OF 2) BUTTERFLY VALVE BASIN ? MASONRY SECTIONAL VIEW
FM-18 (1 OF 2) TYPICAL BLOW-OFF FIRE CISTERN ? MASONRY PLAN
FM-18 (2 OF 2) TYPICAL BLOW-OFF FIRE CISTERN ? MASONRY SECTIONAL VIEW
FM-19
TYPICAL BLOW-OFF FIRE CISTERN ? PRECAST CONCRETE
2
3'-0"
2'-0"
"WATER" OR "SEWER" AS APPROPRIATE
BUILDING CHICAGO TOGETHER RICHARD M. DALEY, MAYOR
4'-0"
DEPARTMENT OF WATER MANAGEMENT
For information about this project, please call (312) 747-3570.
1/2 " PLYWOOD FOR CONSTRUCTION SIGN MOUNTED TO STAND
6"
2'-0"
4" x 4" WOOD POSTS ANCHORED INTO GROUND AND BRACED AS REQUIRED OR AS CALLED FOR IN
SPECIFICATIONS
6"
CL 18"
18"
4"
4"
3'-0"
NOTES:
1. TWO SIGNS (ONE ON EACH END OF EACH PIPE PROJECT) MUST BE DISPLAYED FROM THE TIME CONSTRUCTION BEGINS TO THE TIME THAT PAVEMENT IS RESTORED.
2. THE LOCATION OF THE SIGN WILL BE DETERMINED FOR THE RESIDENT ENGINEER. 3. AFTER THE COMPLETION OF THE CONTRACT THE SIGN WILL BE PROPERTY OF THE
CITY OF CHICAGO AND MUST BE DELIVERED TO THE APPROPRIATE DISTRICT YARD UNLESS ORDERED TO DISCARD BY THE COMMISSIONER.
3'-0"
REV:04.07
PROJECT SIGN
G -1
REV:04.07
SAMPLE SYMBOLOGY LEGEND
G -3
REV:06.07
EXISTING WATER SYMBOLS
W
EXIST MANHOLE WITH WATER VALVE
EXIST WATER VALVE BOX
EXIST WATER BUFFALO BOX
WATER SERVICES CUT-OFF
EXIST WATER METER
EXIST FIRE HYDRANT
EXIST STAND PIPE
EXIST WATER WEDGE VALVE
EXIST 1/4 WATER MAIN BEND
EXIST 1/8 WATER MAIN BEND
I
EXIST 1/16 WATER MAIN BEND
EXIST 1/32 WATER MAIN BEND
EXIST WATER MAIN TEE
EXIST WATER CROSS
EXIST WATER MAIN REDUCER
EXISTING WATER MAIN CAP OR PLUG
EXIST WATER MAIN BLOWOFF
EXIST FIRE CISTERN
EXIST WATER MAIN INSPECTION MANHOLE
EXIST INSPECTION MANHOLE-FEEDER
EXIST WATER MAIN TAP
EXIST WATER MAIN PITOMETER TAP
EXIST TAPPING CONNECTION
EXIST WATER MAIN BUTTERFLY VALVE
EXIST FEEDER MAIN 45 DEG BEND
PRESSURE GAGE
PIPE RISER DOWN
PIPE RISER UP
EXISTING FLARED END
RESTRAINED JOINT PIPE
NO.
NO.
PRESSURE VALVE (RIGHT - LEFT)
PRESSURE VALVE (UP - DOWN)
SEWER SYMBOLS
GAS SYMBOLS
PROPOSED WATER SYMBOLS
NEW WATER VALVE
PROPOSED WATER BUFFALO BOX
NEW FIRE HYDRANT
PROPOSED WATER MAIN SLEEVE
NEW WEDGE VALVE
NEW TAPPING CONNECTION
NEW REDUCER
NEW 1/4 WATER MAIN BEND
NEW 1/8 WATER MAIN BED
NEW 1/16 WATER MAIN BEND
NEW 1/32 WATER MAIN BEND
NEW WATER MAIN TEE
NEW WATER MAIN CAP OR PLUG
PROPOSED WATER MAIN TAP
PROPOSED WATER MAIN INSPECTION MANHOLE
PROPOSED WATER METER
CABLE T.V. SYMBOLS
LEGEND - SYMBOLS
EXIST COMBINED SEWER MANHOLE
EXIST SANITARY SEWER MANHOLE
EXIST STORM WATER MANHOLE
EXIST STORM WATER CATCH BASIN
EXIST STORM WATER INLET
PROPOSED SEWER MANHOLE
PROPOSED STORM WATER CATCH BASIN
EXIST GAS MANHOLE
EXIST GAS VALVE
EXIST CABLE T.V. MANHOLE
EXIST CABLE T.V. PEDESTAL
SURVEY SYMBOLS
100.5
EXIST STREET ELEVATION
SURVEY TRAVERSE POINT
EXIST CONC I.D. MONUMENT
SURVEY CONCRETE MONUMENT
EXIST RIGHT OF WAY MARKER
SURVEYED CHISLED CROSS
EXIST SURVEY IRON PIPE
EXIST PROPERTY CORNER
TRAFFIC SYMBOLS
EXIST TRAFFIC SIGNAL MANHOLE
EXIST TRAFFIC SIGNAL
EXIST TRAFFIC SIGN
T
EXIST TRAFFIC CONTROL BOX
RAILROAD SYMBOLS
EXIST RAILROAD SIGNAL
RAILROAD TRACK PROFILE
RAILROAD COMMUNICATION
ELECTRICAL SYMBOLS
EXIST ELECTRIC MANHOLE
EXISTING COM ED MANHOLE
S
EXIST LIGHT POLE
EXIST. STREET LIGHT CONTROL BOX
EXIST CARRIAGE LIGHT
VEGETATION SYMBOLS
EXIST TREE DECIDUOUS
EXIST TREE CONIFEROUS
EXISTING BUSH
EXIST TREE STUMP
EXIST MARSH SYMBOL
TELEPHONE SYMBOLS
MISCELLANEOUS SYMBOLS
EXIST TELEPHONE MANHOLE
EXIST TELEPHONE PEDESTAL
EXIST TELEPHONE POLE
EXIST UNKNOWN MANHOLE
EXIST UTILITY POLE
EXIST FLAG POLE
EXIST GUY WIRE
BRIDGE COLUMN
MONITORING WELL
EXIST BOLLARD
SOIL BORING
EXIST MAIL BOX
GUARDRAIL
HANDICAPPED SYMBOL
PIPE BREAK SYMBOL
CONCRETE BLOCK
NORTH ARROW
RAMP DISABLED
F
FIRE ALARM BOX
CONCRETE HORIZONTAL THRUST BLOCK
GRAVEL HATCH
CONCRETE HATCH
CONCRETE HATCH
EARTH HATCH
G -4
SHT. 1 OF 2
G -4
SHT. 2 OF 2
LEGEND - LINE STYLES
REV:06.07
SYMBOL
DESCRIPTION Existing-Water Main Existing-Water Services Proposed-Water Main Proposed-New Water Services WM to B-Box
Proposed-New Water Services B-Box to Property
Proposed-Water Main (By Others) Abandoned-Water Main Existing ROW Existing ROW (Vacated) Existing ROW (Elevated) Existing-Easement Proposed-ROW Existing-City Limits Boundary Line Existing-Chicago Park District Line Existing-City Electric Existing-ComEd Existing-Cable TV Existing-Telephone Existing-Sewer Proposed-Sewer Proposed-Sewer Lateral Existing-Sediment Force Main Proposed-Sediment Force Main Abandoned-Sewer Abandoned-Gas
Existing-Gas
SYMBOL
DESCRIPTION Existing-Curb Existing-Sidewalk Existing-Ditches-CreeksEdge of Water Existing-Edge of Pavement Existing-EmbankmentsDead Ends-Retaining Walls Existing-Fence Existing-CTA Buried Electric Cables
Existing-Railroads
Existing-Buried Street Car Tracks
Existing-Steam and Cooling Pipes Existing-City Press Electrical
Existing-Hedge Line
Existing-Woods Tree Line Proposed-Curb Proposed-Sidewalk Proposed-Ditches-CreeksEdge of Water Proposed-Pavement
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- chicago referencing style university college dublin
- convention on international civil aviation
- standard details for water main installations
- machinery eye bolts
- the chicago public art guide
- hey man i m a cubs fan amazon web services
- all aboard detailed fare information
- blues and rock and roll carleton university
- history bmo bank of montreal
Related searches
- wssc standard details for construction
- scholarships details for high school seniors
- water main break in baltimore
- baltimore city water main break
- baltimore county water main break
- baltimore water main break map
- dowdupont split details for shareholders
- johnson county wy water main map
- replace water main valve
- water main valve leaking
- water main break baltimore
- water main breaks in baltimore