AutoCAD System Variables - Autodesk Community
AutoCAD Productivity
Appendix C
AutoCAD System Variables
This section covers: 1. AutoCAD System Variables a. Variable Names b. Default Values c. Commands related to the variable d. Description and settings
All rights reserved by HyperPics for the material and contents. Do not make copies of this material. You created this PDF from an application that is not licensed to print to novaPDF printer ()
AutoCAD Productivity
AutoCAD System Variables
Appendix C - 1
System Variables R12 R2005
What do you want to store or retrieve today?
AutoCAD Systems Variables is where AutoCAD does most of its storing of temporary and some permanent values. These values are related to commands and to control how the user interacts with the AutoCAD Environment. Some of these values are drawing parameters for commands like Offset distance, Circle radius and the Units in which are used to input values when drafting.
Related Commands
Setvar - Calls the System Variable command. Through the use of this command you can set a System Variables value or you can get a listing of all the current settings of all the System Variables.
Command: Setvar Variable name or ?: ? Variable(s) to list : * or
AutoLISP Functions
(setvar variable value) - Sets the value of a System Variable (getvar variable) - Gets the value of a System Variable
Variable _LINFO (Undocumented) (Read-only) (Stored: Not Saved) R12 2005 _PKSER (Read-only) (Stored: Not Saved) R12 2005 _SERVER (Undocumented) (Read-only) (Stored: Not Saved) R12 2005
Default Value
Command(s) affected Environment
Description Hardware lock serial number. Getvar must be used in order to get the value of this system variable.
339-XXXXXXXX Environment
Returns the serial number assigned to AutoCAD.
0
Environment
Returns the status of the network license server
of AutoCAD.
Notes:
All rights reserved by HyperPics for the material and contents. Do not make copies of this material. You created this PDF from an application that is not licensed to print to novaPDF printer ()
AutoCAD Productivity
AutoCAD System Variables
Appendix C - 2
Variable
Default Value
*_TOOLPALETTEPATH (Stored: Registry) R2004 2005
C:\\Documents and Settings\\
Command(s) affected OPTIONS
_VERNUM (Undocumented) (Read-only) (Stored: Not Saved) R13 2005
V.0.73
Environment
ACADLSPASDOC (Stored: Registry) R2000 2005 ACADPREFIX (Read-only) (Stored: Registry) R12 2005 ACADVER (Read-only) (Stored: Not Saved) R12 2005
0
PREFERENCES
OPTIONS
C:\Program \ PREFERENCES OPTIONS
16.1
Environment
Description Contains the pathing for the Tool Palettes. So it allows you to change different Tool Palettes based on different ones being stored in different directories. A semi-colon (;) separates each path. Returns a build number for AutoCAD. It allows you to tell what service pack is installed for AutoCAD. R13_c4a - R.1.72c
R14.0 - S.0.79 R14.01 - P.0.31 R2000 - T.1.07 R2000i - U.0.90 R2002 - K.0.30 (SP1 K.0.44) R2004 - V.0.73 (SP1a V.1.22) R2005 - "N.30.101" (SP1 N.84.0) Controls how AutoCAD will load the Acad.lsp file. 0 - Loads into every drawing opened 1 - Loads into the first drawing opened only. List of support paths used by AutoCAD. These paths may vary from the actual working paths for AutoCAD.
Version number of AutoCAD 14.0 - R14
14.01 - R14 15.0 - R2000
15.05 - R2000i 15.06 - R2002
16.0 - R2004 16.1 - R2005
Notes:
All rights reserved by HyperPics for the material and contents. Do not make copies of this material. You created this PDF from an application that is not licensed to print to novaPDF printer ()
AutoCAD Productivity
AutoCAD System Variables
Variable ACIS15 (Stored: Not Saved) R13
Default Value 0
Command(s) affected Environment
ACISOUTVER
70
(Stored: Not Saved)
R14 2005
ADCSTATE
0
(Undocumented)
(Read-only)
(Stored: Not Saved)
R2000i 2005
AFLAGS
0
(Stored: Not Saved)
R12 2005
ACSIOUT EXPORT ADCENTER ADCCLOSE
DDATTDEF ATTDEF
ANGBASE (Stored: In Drawing) R12 2005 ANGDIR (Stored: In Drawing) R12 2005 APBOX (Stored: In Registry) R14 2005
0.0000 0 0
DDUNITS UNITS DDUNITS UNITS DDOSNAP OSNAP
Appendix C - 3
Description Format in which AutoCAD processes all solid objects. 0 - ACIS data is saved in ACIS 1.6 format and
can only be read by c4 or later versions. 1 - ACIS data is saved in both ACIS 1.5 and
ACIS 1.6 format in two different places. ACIS version of SAT files created using the ACISOUT command. Valid values are 15 18, 20, 21, 30, 40, 50, 60 and 70. Holds the display state of the AutoCAD Design Center. 0 - Not displayed in the environment 1 - Currently displayed in the environment
Default values for attribute creation modes. (sum of the following) 0 - No mode present 1 - Invisible 2 - Constant 4 - Verify 8 - Preset Direction of Angle 0 (relative to the current UCS)
Angle of rotation 0 - Counterclockwise 1 - Clockwise AutoSnap aperture box display 0 - Off 1 - On
Notes:
All rights reserved by HyperPics for the material and contents. Do not make copies of this material. You created this PDF from an application that is not licensed to print to novaPDF printer ()
AutoCAD Productivity
AutoCAD System Variables
Appendix C - 4
Variable APERTURE (Stored: In Registry) R12 2005 AREA (Read-only) (Stored: Not Saved) R12 2005 ASSISTSTATE (Stored: Not Saved) R2005 ATTDIA (Stored: In Registry) R12 2005 ATTMODE (Stored: In Drawing) R12 2005
ATTREQ (Stored: In Registry) R12 2005 AUDITCTL (Stored: In Registry) R12 2005
Default Value 10 0.0000 0 0 1
1 0
Command(s) affected DDOSNAP OSNAP AREA DBLIST LIST ASSIST ASSISTCLOSE DDATTE ATTDISP
INSERT AUDIT
Description Aperture size for object snap (pixels) 1 - Minimum 50 - Maximum Last calculated area by Area, List or Dblist
Indicates the display status of the AutoCAD Info Palette. 0 - Info Palette is not active 1 - Info Palette is active Attribute interface for entry: 0 - Command line prompts 1 - Dialog Box Display of Attributes on the screen. 0 - Off, All attributes are turned off regardless
of flags set 1 - Normal, All attributes use the flags they
were originally defined with 2 - On, All attributes are turned on regardless
of flags set Determines if Attribute defaults are used when inserting a symbol. 0 - Default Values 1 - Prompt for values Determines if a Log file is generated with each Audit performed. File has the extension ADT. 0 - No Audit log is written 1 - Audit log is written
Notes:
All rights reserved by HyperPics for the material and contents. Do not make copies of this material. You created this PDF from an application that is not licensed to print to novaPDF printer ()
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- environment variables optimise your system e 20 1 take control of
- dynamic environment manager vmware
- unsw it install guide for windows matlab
- autocad system variables autodesk community
- openjdk 11 installing and using openjdk 11 for windows
- a comprehensive checklist for windows hardening hurricane labs
- windows registry some basic understanding idc online
- how to set the path and environment variables in windows
- simon s win32 cheat sheet
- environment variables university of washington
Related searches
- system variables are not editable
- autodesk autocad 2019 student download
- autocad autodesk student version
- autodesk autocad 2020 student download
- autodesk autocad 2019 free download
- autodesk autocad 2021 free download
- autodesk autocad lt 2018 download
- download autodesk autocad 2018 student
- autodesk autocad 2018 download
- autodesk autocad 2018 download free
- autodesk autocad electrical 2016
- autocad autodesk 2014