Www.vendorportal.ecms.va.gov



FedBizOppsCombined Synopsis/Solicitation Notice*******CLASSIFICATION CODESUBJECTCONTRACTING OFFICE'SZIP-CODESOLICITATION NUMBERRESPONSE DATE (MM-DD-YYYY)ARCHIVEDAYS AFTER THE RESPONSE DATERECOVERY ACT FUNDSSET-ASIDENAICS CODECONTRACTING OFFICEADDRESSPOINT OF CONTACT(POC Information Automatically Filled fromUser Profile Unless Entered)DESCRIPTION*See AttachmentAGENCY'S URLURL DESCRIPTIONAGENCY CONTACT'S EMAILADDRESSEMAIL DESCRIPTIONADDRESSPOSTAL CODECOUNTRYADDITIONAL INFORMATIONGENERAL INFORMATIONPLACE OF PERFORMANCE* = Required FieldFedBizOpps Combined Synopsis/Solicitation NoticeRev. March 201066502-14-3-084-0060 - Prosim Vital Signs simulator(Alexandria) - VA256-14-AP-7065Signal Generators and Life Vital Sign Simulators forBiomedical Engineering71360-9004VA256-14-Q-107807-02-201430N16334515DEPARTMENT OF VETERANS AFFAIRSALEXANDRIA VA HEALTH CARE SYSTEMP&C DEPARTMENT (90C)PO BOX 69004ALEXANDRIA LA 71360-9004Paul G FilhiolContracting Officer318-466-4206DEPARTMENT OF VETERANS AFFAIRSALEXANDRIA VA HEALTHCARE SYSTEM2495 SHREVEPORT HIGHWAYBLDG 136Pineville, LA71360USApaul.filhiol@paul.filhiol@This is a procurement of Signal Generators and Vital Sign Simulators used to test Defibillators and Monitors in Biomedical Engineering. Please see the schedule in the attached RFQ for a full description of the required items. Items noted as being “Brand Name or Equal” in the RFQ have their salient charachteristics described below.This is a Woman-Owned Small Business set-aside.Quotes can be emailed to paul.filhiol@ until closing on 2 July at 6:00PM ET.Salient Characteristics for Equal Items DATE \@ "M/d/yyyy" 6/19/2014Brand Name Item: Impulse 7000DP Defibrillator Test, External Pacer AnalyzerEssential/significant physical, functional, or performance characteristics.-Lown, Edmark, trapezoidal, biphasic, and pulsed-biphasic defibrillation technology compatibility-AED compatibility-12 lead ECG simulation-Internal Pacer brand selections-Flexible heart-rate setting at 1BPM increments-Accuracy of +/- 1% of reading +0.1J-Rechargeable Battery-LCD display-Battery Charger-In accordance with safety standards: CE:IEC/EN61010-1 2nd edition; Pollution degree 2 CAN/CSA-C22.2 No. 61010-1; UL61010-1 C-Tick-Range of .1Joule-600Joule-Load resistance of 50 ohms-Pulse Trigger level of 20V-Pulse Width range of 1ms-50ms-Voltage range of 20V-5000V-Current range of .4A-100A-Charge time measurement with range of .1s-100s-Synchronization test-Automated Defibrillator test ECG waves-Carrying CaseCompatibility Dimensions WeightIndustry Standard-IEC 60601-2-4 Compliance Purpose – quality assurance testing on all vital monitor equipment at the Alexandria VAGoverning Body or Organization –Complete generic identification – Defibrillator and Automated External Defibrillator tester to conduct quality assurance testing, calibration, and safety inspections.Applicable model/make/catalog number – Impulse 7000DP Defibrillator Tester, External Pacer AnalyzerManufacturer name – Fluke BiomedicalPer VAAR 811.104 and 811.105, I certify the following regarding the above information:The salient characteristics listed above are essential to the Government’s requirements.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture._Leigh Ruiz______________________________Name: DATE \@ "M/d/yyyy" 6/19/2014Brand Name Item: ProSim 8 Vital Signs SimulatorEssential/significant physical, functional, or performance characteristics.-All in one patient simulatorECG (electrocardio graph) up to 6 lead with amplitude accuracy of +/- (2% of setting + .005 mV), rate of 10-360 bpm in 1 bpm steps with accuracy of +/- 1% of settingArrhythmia up to 50 selectionsRespirationTemperature 30-42 degrees celcius with accuracy of +/-.4degreesIBP (invasive blood pressure) 2 channelsNIBP (Noninvasive blood pressure0 measured in mmHg or kPa with manometer range of 10-400mmHg, leak testing, pressure relief testCardiac Output.SpO2-compatible with Nellcor, Masimo, Nonin, Nihon Kohden, Mindray, GE-Ohmeda, Philips/HP, and BCI-Direct data capture and printing functionality-internal pressure pump-continuous static pressure change-LCD color display-Lithium-ion rechargeable battery with 9 hour battery life-Battery Charger-Carrying Case-Cables to connect with Drager Infinity moniors-accessory kitsCompatibility Dimensions WeightIndustry Standard – Complies with IEC 61326-1:2006Purpose – quality assurance testing on all vital monitor equipment at the Alexandria VAGoverning Body or Organization –Complete generic identification –.Comprehensive patient monitor tester for quality assurance and safety.Applicable model/make/catalog number – ProSim 8Manufacturer name – Fluke BiomedicalPer VAAR 811.104 and 811.105, I certify the following regarding the above information:The salient characteristics listed above are essential to the Government’s requirements.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture._Leigh Ruiz______________________________Name: DATE \@ "M/d/yyyy" 6/19/2014Brand Name Item: DPM2Plus Universal Pressure meterEssential/significant physical, functional, or performance characteristics.-handheld-battery operated-1%accuracy-Capability to test ophthalmology equipment, lasers, dialysis machines, automatic tourniquets, drainage devices, IV pumps, pressure gauges, ventilators, diagnostic, surgical suction devices-operating range of -698mmHg to 802 mmHg-949cmH2O to 1090 cmH2O-374 inH2O to 429 inH2O-13.5 PSI to 15.5 PSI-13.5 PSI to 100 PSI-units of measure mmHg, cmH2O, inH2O, PSICompatibility Dimensions WeightIndustry Standard Purpose – quality assurance testing on all vital monitor equipment at the Alexandria VAGoverning Body or Organization –Complete generic identification - Universal Pressure Meter designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form to assist in repair and quality control.Applicable model/make/catalog number – DPM2Plus Universal Pressure meterManufacturer name – Fluke BiomedicalPer VAAR 811.104 and 811.105, I certify the following regarding the above information:The salient characteristics listed above are essential to the Government’s requirements.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture._Leigh Ruiz______________________________Name: DATE \@ "M/d/yyyy" 6/19/2014Brand Name Item: ESA615-10-NA220V Electrical Safety AnalyzerEssential/significant physical, functional, or performance characteristics.-Automated test sequences IEC60601-1 2nd EditionIEC62353NFPA-99(Hospital)ANSI/AAMI ES-1-ECG waveform tests and dual-lead measurements for up to 12 lead testing-two year warranty-Power Cord US with C19 Plug-NA 220V adapter kit-Power Cord NA 220V-voltage testing (mains and point to point)-range for mains voltage (90VAC RMS-132VAC RMS)-Range for accessible voltage (180 VAC RMS -264 VAC RMS)-Accuracy of +/- (2% of reading + .2V)-Earth Resistance Testing (earth and point to point)-two-wire-CurrentRange (0A-20ADuty Cycle (15A-20A, 5min on/5min off), (10A-15A 7min on/3 min off), (0A-10A continuous)-Leakage Current-AC+DC-AC only-DC only-Ranges (0microamps-199.9microamps, 200microamps-1999microamps, 2mA-10mA)-Leakage testsGround Wire (earth)Chassis (enclosure)Lead to ground (patient)Lead to lead (patient auxiliary)Lead isolation (mains on applied part)Direct equipmentDirect applied partAlternative equipmentAlternative applied partPoint to Point-Carrying CaseCompatibility Dimensions WeightIndustry Standard Purpose – quality assurance testing on all vital monitor equipment at the Alexandria VAGoverning Body or Organization –Complete generic identification – Automated and portable Electrical Safety Analyzer used to conduct electrical safety inspections on medical equipmentApplicable model/make/catalog number – ESA615-10-NA220V Electrical Safety AnalyzerManufacturer name – Fluke BiomedicalPer VAAR 811.104 and 811.105, I certify the following regarding the above information:The salient characteristics listed above are essential to the Government’s requirements.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture._Leigh Ruiz______________________________Name: DATE \@ "M/d/yyyy" 6/19/2014Brand Name Item: ESA615 Electrical Safety AnalyzerEssential/significant physical, functional, or performance characteristics.-Automated test sequences IEC60601-1 2nd EditionIEC62353NFPA-99(Hospital)ANSI/AAMI ES-1-ECG waveform tests and dual-lead measurements for up to 12 lead testing-two year warranty-20A at 120V current capability-voltage testing (mains and point to point)-range for mains voltage (90VAC RMS-132VAC RMS)-Range for accessible voltage (180 VAC RMS -264 VAC RMS)-Accuracy of +/- (2% of reading + .2V)-Earth Resistance Testing (earth and point to point)-two-wire-CurrentRange (0A-20ADuty Cycle (15A-20A, 5min on/5min off), (10A-15A 7min on/3 min off), (0A-10A continuous)-Leakage Current-AC+DC-AC only-DC only-Ranges (0microamps-199.9microamps, 200microamps-1999microamps, 2mA-10mA)-Leakage testsGround Wire (earth)Chassis (enclosure)Lead to ground (patient)Lead to lead (patient auxiliary)Lead isolation (mains on applied part)Direct equipmentDirect applied partAlternative equipmentAlternative applied partPoint to Point-Carrying CaseCompatibility Dimensions WeightIndustry Standard Purpose – quality assurance testing on all vital monitor equipment at the Alexandria VAGoverning Body or Organization –Complete generic identification – Automated and portable Electrical Safety Analyzer used to conduct electrical safety inspections on medical equipmentApplicable model/make/catalog number – ESA615 Electrical Safety AnalyzerManufacturer name – Fluke BiomedicalPer VAAR 811.104 and 811.105, I certify the following regarding the above information:The salient characteristics listed above are essential to the Government’s requirements.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture._Leigh Ruiz______________________________Name:See attached document: VA256-14-Q-1078. ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download