Dual purpose arc fault/ground fault circuit interrupter
Dual purpose AF/GF Arc fault/ground fault circuit interrupter
Dual purpose arc fault/ground fault circuit interrupter
Eaton is expanding its line of arc fault and ground fault solutions to include the dual purpose arc fault/ground fault (AF/GF) circuit interrupter for residential and light commercial applications. The AF/GF circuit interrupter was developed in response to the 2014 National Electrical Code (NECT) that now requires AFCI protection in kitchens and laundry areas as well as the historical requirement of ground fault protection. Eaton's AF/GF circuit interrupter will offer both types of protection in one familiar package.
The AF/GF circuit interrupter provides quick installation and a single location to easily access and identify tripped circuits.
Features and benefits
? Provides one device for both AFCI and GFCI protection, allowing for a single point of reset
? Offers complete protection from arc and ground faults for the entire circuit, including home-runs
? Enables a lower installed cost versus other code-approved alternatives by using only one device to achieve both AFCI and GFCI protection
Key differentiators
? Eaton's proven reliability of arc-fault detection to reduce unwanted tripping due to interaction with devices or appliances
? Integral LED indicates seven different trip causes, reducing troubleshooting time
Why Eaton?
Eaton understands the importance of safety in the home. At Eaton, our expertise, impactful solutions and customerfocused approach enable us to develop innovative solutions for what matters most to you.
Eaton provides a broad range of circuit protection solutions and expertise that support enhanced safety, reliability and efficiency for global applications. Eaton has a heritage of innovation in circuit protection that dates back to 1914 and continues to invest in research and development to provide industry-leading solutions.
Type CH (3/4-inch) CHFAFGF selection chart
Amperes
Standard--Pigtail 15 20 Plug-On Neutral 15 20
Number of Poles
1 1
1 1
kAIC
10 10
10 10
Catalog Number
CHFAFGF115 CHFAFGF120
CHFAFGF115PN CHFAFGF120PN
Type CH specifications
Description
Catalog number Voltage requirement Frequency requirement Power consumption Surge Ambient operating temperature Humidity Warranty ULT standards
UL file number
Specification
CHFAFGF115, CHFAFGF120, CHFAFGF115PN, CHFAFGF120PN 102 VRMS 132 60 Hz ? 2 Hz 1.3 W In accordance with IEC 61000-4-5 ?31 ?F to +150 ?F (?35 ?C to +66 ?C) 0% to 95%, noncondensing Limited lifetime A UL 489--molded-case circuit breakers, molded-case switches and circuit breaker enclosures UL 943--ground fault circuit interrupters UL 1699--arc fault circuit interrupters UL 1998--software in programmable components E-45310
A Reference WA00301001Y for warranty details.
Type BR (1-inch) BRLAFGF selection chart
Amperes
Standard--Pigtail 15 20
Number of Poles
1 1
kAIC
10 10
Catalog Number
BRLAFGF115 BRLAFGF120
Type BR specifications
Description
Catalog number Voltage requirement Frequency requirement Power consumption Surge Ambient operating temperature Humidity Warranty UL standards
UL file number
Specification
BRLAFGF115, BRLAFGF120 102 VRMS 132 60 Hz ? 2 Hz 1.3 W In accordance with IEC 61000-4-5 ?31 ?F to +150 ?F (?35 ?C to +66 ?C) 0% to 95%, noncondensing 10-year A UL 489--molded-case circuit breakers, molded-case switches and circuit breaker enclosures UL 943--ground fault circuit interrupters UL 1699--arc fault circuit interrupters UL 1998--software in programmable components E-45310
A Reference WA00302001Y for warranty details.
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States
? 2014 Eaton All Rights Reserved Printed in USA Publication No. PA003006EN / Z15717 September 2014
Eaton is a registered trademark.
All other trademarks are property of their respective owners.
For more information, visit
afgf or call 1-877-ETN-CARE (877-386-2273)
To find a local sales office or a distributor, visit
howtobuy
3 MURRAY
Circuit Breakers
Arc-Fault Circuit Interrupters (AFCI)
? Revised ? 06/13/14
Combination Type AFCI b
AFCI's detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The Combination Type AFCI detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected.
Breaker Type
MP-AT2/MP-HAT2/ MP-MAT2
1-Pole 120V AC
Ampere 10,000 A IR
22,000 A IR
65,000 A IR
Rating Catalog Number Catalog Number Catalog Number
15
MPA115AFCa
MPA115AFCHna MPA115AFCHH
20
MPA120AFCa
MPA120AFCHna MPA120AFCHH
MP-AT2/MP-HAT2 15
2-Pole 120/240V AC
20
MP215AFCa MP220AFCa
MP215AFCHna -- MP220AFCHna --
? UL Listed
? HACR & SWD Rated
? Standard 1 inch per pole format with plugin design
Branch-Feeder AFCI
AFCI's detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The Branch-Feeder AFCI detects line-to-ground and line-to-neutral arcs. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected.
MP-AT2/MP-HAT2/ MP-MAT2
15 20
1-Pole 120V AC
MPA115AFa MPA120AFa
MPA115AFHna MPA120AFHna
MPA115AFHH MPA120AFHH
1-Pole Combination 2-Pole Combination
Type AFCI
Type AFCI
NEW Dual Function AFCI/GFCI
The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and Ground Faults. The device includes the Self Test and Lockout feature, making it the fist in class in electrical safety for homeowners.
MP-GAT2/MP-HGAT2/ 15
MP-MGAT2
20
1-Pole 120V AC
MP115DF MP120DF
MP115DFH MP120DFH
MP115DFM MP120DFM
Circuit Breakers
Ground-Fault Circuit Interrupters (Class A - 5mA)b
Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a device intended for personnel protection and will de-energize the circuit when a fault current to ground is 6 milliamperes or more.
Breaker Type
Amp 10,000 A IR 22,000 A IR Rating Catalog No. Catalog No.
MP-GT/ 15
MP-HGT
1-Pole 120V AC
20 25 30
MP115 GFa MP115GFHna MP120 GFa MP120GFHna MP125 GFn -- MP130 GF MP130GFHn
15
MP-GT/ 20
MP-HGT 30
2-Pole
40
120/240V 50
AC
60
MP215 GF
MP220 GF MP230 GF MP240 GF MP250 GF MP260 GF
MP215GFHn MP220GFHn MP230GFHn MP240GFHn MP250GFHn MP260GFHn
Ground Fault Equipment
Protection (30mA)b
Type EQF circuit breakers provide protection of equipment from damaging line-to-ground fault currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit.
Breaker Amp 10,000 A IR 22,000 A IR
Type
Rating Catalog No. Catalog No.
MP-ET/ 15
MP-HET 20
1-Pole 120V AC
30
MP115 EGa MP115EGHna MP120 EGa MP120EGHna MP130 EG MP130EGHn
15
MP-ET/ 20
MP-HET 30
2-Pole
40
120/240V
AC
50
60
MP215 EG MP215EGHn MP220 EG MP220EGHn MP230 EG MP230EGHn MP240 EG MP240EGHn MP250 EG MP250EGHn MP260 EGn MP260EGHn
AFCI and GFCI Accessories
Description Padlocking Device for 1" & Twin Breakers Padlocking Device for 2" & Quad Breakers Handle Blocking Device for 1/2" Circuit Breakers
Catalog Number ECPLD1 ECPLD2 ECBX231M
n Built to order. Allow 2?3 weeks for delivery.
a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.
b White line neutral (pigtail) must be connected to the panel neutral for the device to function.
1-Pole Branch Feeder AFCI
1-Pole GFCI
2-Pole GFCI
Product Category RESI
Siemens Industry, Inc. SPEEDFAXTM 2011 Product Catalog
3-13
MURRAY 3
Circuit Breakers
Full Size (1" per Pole) with INSTA-WIRE
Type MP-T
Type MP-HT
Continuous Current Rating @ 40? C
10,000A IR Catalog Number
22,000A IR Catalog Number
1-Pole Plug-In (120V AC)e
10
MP110
--
15
MP115d
MP115KHd
20
MP120d
MP120KHd
25
MP125
MP125KHn
30
MP130
MP130KH
35
MP135n
MP135KHn
40
MP140
MP140KH
45
MP145n
MP145KHn
50
MP150
MP150KH
60
MP160n
MP160KHn
70
MP170n
MP170KHn
2-Pole Plug-In (Common-Trip 120/240V AC )f
15
MP215
MP215KH
20
MP220
MP220KH
25
MP225
MP225KHn
30
MP230
MP230KH
35
MP235
MP235KHn
40
MP240
MP240KH
45
MP245
MP245KHn
50
MP250
MP250KH
60
MP260
MP260KH
70
MP270
MP270KHn
80
MP280
MP280KHn
90
MP290
MP290KHn
100
MP2100
MP2100KH
110
MP2110
MP2110KH
125
MP2125
MP2125KH
2-Pole Plug-In (Common-Trip 240V AC)cf
15
MPH215
--
20
MPH220
--
30
MPH230
--
40
MPH240n
--
50
MPH250
--
60
MPH260
--
70
MPH270n
--
100
MPH2100n
--
3-Pole Plug-In (Common-Trip 240V AC)g
15
MP315
MP315KH
20
MP320
MP320KH
25
MP325n
MP325KHn
30
MP330
MP330KH
35
MP335n
--
40
MP340
MP340KH
45
MP345n
--
50
MP350
MP350KH
60
MP360
MP360KH
70
MP370
MP370KH
80
MP380
MP380KHn
90
MP390
MP390KHn
100
MP3100
MP3100KH
MP-T / MP-HT / MP-MT Internal Accessories
Description
Catalog Number Field/Factory Installed
120V Shunt Trip
add suffix...STn
Factory
24V Shunt Trip 120V Auxiliary Switch
add suffix...ST24Vn add suffix...ASnb
Factory Factory
? Revised ? 03/06/13
Type MP-MT 65,000A IR Catalog Number
-- MP115KMnd MP120KMnd MP125KMn MP130KMn MP135KMn MP140KMn MP145KMn MP15KKMn MP160KMn MP170KMn
1-Pole
MP215KMn MP220KMn MP225KMn MP230KMn MP235KMn MP240KMn MP245KMn MP250KMn MP260KMn MP270KMn -- MP290KMn MP2100KM MP2110KMn MP2125KM
2-Pole 3-Pole
-- -- -- -- -- -- -- --
MP315KMn MP320KMn -- MP330KM -- MP340KM -- MP350KM MP360KM MP370KMn MP380KMn MP390KMn MP3100KM
Wiring Diagrams
Modifications
Description 400Hz Calibration Marine 50? C Ambient Calibration Fungus Proofing
Catalog Number add suffix...Y h
add suffix...M add suffix...F
For external accessories please refer to page 3-20.
Circuit Breakers
n Built to order. Allow 2-3 weeks for delivery
a UL Listed for use with 60/75? wire through 40 amps, UL listed for use with 75? wire only for 50 amps and above, HACR rated. 120V AC Fluorescent Lighting.
b 1A and 1B contacts. cUL Listed for use on 3 phase grounded "B" systems --
10,000 for this application. d UL Listed for frequent switching applications (SWD). e Shipped 12 per sleeve.
3-14
Siemens Industry, Inc. SPEEDFAXTM 2011 Product Catalog
f Shipped 6 per sleeve. g Shipped 4 per sleeve. h ULListed 5KAIR. i Not ULListed. j 1 &2 Poles only.
Product Category RESI
3 MURRAY
Circuit Breakers
Duplex, Triplex and Quadplex Plug-in Breakers
Duplex Circuit Breakers
Breaker Type
MH-T
1-Pole 10K AIC 120V AC
Ampere Rating
Catalog Number
15 ?15
MP1515
15 ? 20
MP1520
20 ? 20
MP2020
20 ? 30
MP2030
15? 30
MP3015n
30 ? 30
MP3030
SHIPPING: 12 per carton, (Wt. 4.8 lbs.)
Catalog Number
MP1515Na MP1520Nna MP2020Na MP2030Nna MP3015Nna MP3030Nna
Triplex Circuit Breakers
Breaker Type
MH-T
2-Pole 10K AIC 120/240V AC Inner Poles Common Trip. Outter Poles 1 Pole Units
Ampere Rating
Single Pole
Common-Trip 2-Pole
15
15
15
20
15
25
15
30
15
35
15
40
15
45
15
50
20
20
20
25
20
30
20
35
20
40
20
45
20
50
SHIPPING: 6 per carton, (Wt. 4.9 lbs.)
Catalog Number
MP21515 MP22015 MP22515n MP23015 MP23515n MP24015 MP24515n MP25015 MP22020 MP22520n MP23020 MP23520n MP24020 MP24520n MP25020
Quadplex Circuit Breakers
Breaker Type
MH-T
2-Pole 10K AIC 120/240V AC Outter and Inner 2 Poles Common Trip
Ampere Rating
Single Pole
Common-Trip 2-Pole
15
15
15
20
20
30
20
40
30
30
30
40
40
40
50
30
SHIPPING: 6 per carton, (Wt. 4.8 lbs.)
Catalog Number
MP215215CT2 MP220220CT2 MP220230CT2 MP220240CT2 MP230230CT2 MP230240CT2 MP240240CT2 MP250230CT2
For external accessories please refer to page 3-20.
MH-T Duplex
These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated.
MH-T Triplex
These space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated.
MH-T Quadplex
These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated.
Circuit Breakers
n Built to order. Allow 2?3 weeks for delivery.
Product Category RESI
aNon-CTL.. For replacement use only in panels manufactured before 1968.
Siemens Industry, Inc. SPEEDFAXTM 2011 Product Catalog
3-15
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- easily troubleshoot any afci circuit
- power product molded case circuit breakers siemens
- sentron residual current protective devices siemens
- wiring practices troubleshooting with afcis
- arc fault and ground fault breakers
- plug on neutral load centers and electronic breakers
- dual purpose arc fault ground fault circuit interrupter
- swimlife owner s manual
- basics of afci circuit breakers
- tandem combination type arc fault circuit interrupters cafci