Revised on 05/31/18 Circuit Breakers

LOAD CENTERS & 1

CIRCUIT BREAKERS

Circuit Breakers

Arc-Fault and Ground-Fault Breakers

Arc-Fault Circuit Interrupters (AFCI)

AFCI's detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected.

Combination Type AFCI

Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.

Breaker Type

Ampere 10,000 A IR Rating Catalog No.

22,000 A IR Catalog No.

65,000 A IR Catalog No.

QAF2/QAFH2/HQAF2 15

1-Pole 120V AC

20

QAF/QAFH

15

2-Pole 120/240V AC

20

QA115AFC QA120AFC

Q215AFC Q220AFC

QA115AFCH QA120AFCH

Q215AFCHn Q220AFCHn

QA115AFCHHn QA120AFCHHn

-- --

Branch-Feeder AFCI

Detects line-to-ground and line-to neutral arcs.

QAF2/QAFH2/HQAF2 15

1-Pole 120V AC

20

QA115AF QA120AF

QA115AFHn QA120AFHn

QA115AFHHn QA120AFHHn

NEW Dual Function AFCI/GFCI

The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test feature, making it the first in class in electrical safety for homeowners.

QFGA2/QFGAH2/ HQFGA2

1-Pole 120V AC

15

Q115DF

Q115DFHn

Q115DFHHn

20

Q120DF

Q120DFH

Q120DFHHn

Ground-Fault Circuit Interrupters (GFCI)

Provides Class A (5mA) ground fault protection. Intended for personnel protection. Includes Self Test as an added safety feature.

Breaker Type

Amp

10,000 A IR

Rating Catalog No.

22,000 A IR Catalog No.

65,000 A IR Catalog No.

QPF2/QPHF2/HQPF2

15 20

1-Pole 120V AC Plug-in

30

15

20

QPF/QPHF

30

2-Pole 120/240V AC Plug-in

40

50

60

QF115Aa QF120Aa QF130Aa

QF215A QF220A QF230A QF240A QF250A QF260A

QF115AHna QF120AHna QF130AHna

QF215AHn QF220AHn QF230AHn QF240AHn QF250AHn QF260AHn

QF115AHHna QF120AHHna QF130AHHna

-- -- -- -- --

--

Ground Fault Equipment Protection (30mA)

Provides protection of equipment from damaging line-to-ground faults currents. De-energizes the circuit for all ungrounded conductors of the circuit.

QE/QEH

15 20

1-Pole 120V AC Plug-in

30

15

20

QE/QEH

30

2-Pole 120/240V AC Plug-in

40

50

60

QE115 QE120 QE130

QE215 QE220 QE230 QE240 QE250 QE260

QE115Hn

--

QE120Hn

--

QE130Hn

--

QE215Hn

--

QE220Hn

--

QE230Hn

--

QE240Hn

--

QE250Hn

--

QE260Hn

--

QAF2/QPF/QE/QPF2 Accessories

Description Padlocking Device 1-Pole Padlocking Device 2-Pole Handle Block

Catalog Number ECPLD1 ECPLD2 ECBX231M

n Built to order. Allow 8 -10 weeks for delivery.

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Add WG to the part number for the WireGuide version.

1-34 Siemens Industry, Inc. SPEEDFAXTM 2017 Product Catalog

Revised on 05/31/18

Selection/Wiring Diagrams

? UL Listed

? HACR Rated

1-Pole Combination Type AFCI

2-Pole Combination Type AFCI

1-Pole Branch Feeder AFCI

1-Pole Dual Function AFCI/GFC

1-Pole GFCI

2-Pole GFCI

1-Pole Equipment Protection

2-Pole Equipment Protection

Wiring Diagrams

Product Category RESI

LOAD CENTERS &

1 CIRCUIT BREAKERS

Circuit Breakers

Dual Function Arc-Fault and Ground-Fault breaker

Two state-of-the-art technologies combined in one device! Dual Function Circuit Breakers: QFGA2/QFGAH2/HQFGA2

Introducing the Dual Function Circuit Breaker that provides Arc Fault and Ground Fault protection in one device. The 2014 National Electric Code requires Arc Fault protection on Kitchen and Laundry circuits where Ground fault protection is currently a requirement. One solution to meet this code is to pair an AFCI circuit breaker with a GFCI receptacle. The Dual function breaker will replace the Arc fault breaker and the Ground Fault receptacle. Additionally, the breaker will help eliminate the use of two separate devices and improve cost savings.

Features ? Plug-in or bolt-on branch circuit breakers for

Siemens single phase load centers

? Self Test feature as required by UL 1699 effective June 2015

? Saving time ? ease of installation ? only One product to install vs. Two

? Saving money ? Two safety devices combined into One.

? LED trip indicator ? a Siemens exclusive!

? Available with interrupting rating of 10kA, 22kA or 65kA

? UL Listed

? Torque rating: 25 lb. in.

? Padlocking device available, use catalog number ECPLD1

? Both lugs at the same angle - for easier wiring

Revised on 05/31/18

1-Pole Dual Function Circuit Breaker

Siemens Industry, Inc. SPEEDFAXTM 2017 Product Catalog 1-35

LOAD CENTERS & 1

CIRCUIT BREAKERS

Circuit Breakers

Type QP with INSTA-WIRE

Continuous Current Rating @ 40? C

Type QP 10,000A IR Catalog Number

Type QPH 22,000A IR Catalog Number

1-Pole Plug-In (120V AC)e

10

Q110

15

Q115c

20

Q120c

25

Q125

30

Q130

35

Q135n

40

Q140

45

Q145n

50

Q150

60

Q160

70

Q170

-- Q115Hc Q120Hc Q125Hn Q130H Q135Hn Q140H Q145Hn Q150H Q160Hn Q170Hn

2-Pole Plug-In (Common-Trip 120/240V AC)

10

Q210

--

15

Q215

Q215H

20

Q220

Q220H

25

Q225

Q225Hn

30

Q230

Q230H

35

Q235

Q235Hn

40

Q240

Q240H

45

Q245

Q245Hn

50

Q250

Q250H

60

Q260

Q260H

70

Q270

Q270H

80

Q280

Q280Hn

90

Q290

Q290H

100

Q2100

Q2100H

110

Q2110

Q2110H

125

Q2125

Q2125H

2-Pole Plug-In (Common-Trip 240V AC)

15

Q215R

--

20

Q220R

--

30

Q230R

--

40

Q240R

--

50

Q250R

--

3-Pole Plug-In (Common-Trip 240V AC)

15

Q315

Q315H

20

Q320

Q320H

25

Q325

Q325Hn

30

Q330

Q330H

35

Q335

Q335Hn

40

Q340

Q340H

45

Q345

Q345Hn

50

Q350

Q350H

60

Q360

Q360H

70

Q370

Q370H

80

Q380

Q380H

90

Q390

Q390H

100

Q3100

Q3100H

Type HQP 65,000A IR Catalog Number

-- Q115HHnc Q120HHnc Q125HHn Q130HHn Q135HHn Q140HHn Q145HHn Q150HHn Q160HHn Q170HHn

-- Q215HH Q220HH Q225HHn Q230HH Q235HHn Q240HHn Q245HHn Q250HH Q260HH Q270HH Q280HHn Q290HHn Q2100HH Q2110HHn Q2125HH

-- -- -- -- --

Q315HHn Q320HH Q325HHn Q330HH Q335HHn Q340HH Q345HHn Q350HH Q360HH Q370HHn Q380HHn Q390HHn Q3100HH

Q120 Q220 Q320

QP / QPH / HQP Internal Accessories

Control Voltage AC 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch

Catalog Number add suffix ...00S01n add suffix ...00S07n add suffix ...01nb

Field/Factory Installed Factory Factory Factory

Modifications

Description 400 Hz Calibration Marine 50?C Ambient Calibration Fungus Proofing

n Built to order. Allow 2-3 weeks for delivery.

a UL Listed for use with 60/75? wire through 40 amps, UL listed for use with 75? wire only for 50 amps and above, HACR rated.

\b 1A and 1B contacts.

c UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting.

d UL Listed for use on 3-phase grounded "B" systems -- 10,000 for this application.

e Shipped 12 per sleeve.

Catalog Number add suffix ...Yh

add suffix ...M add suffix ...F

For external accessories please refer to page 1-43.

f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5 KA IR. i Type QP1, UL listed for 16 AWG conductors and

multiple wires.

1-36 Siemens Industry, Inc. SPEEDFAXTM 2017 Product Catalog

Product Category RESI

LOAD CENTERS &

1 CIRCUIT BREAKERS

Circuit Breakers

Duplex, Triplex and Quadplex Plug-In Breakers

Duplex Circuit Breakers

Breaker Type

QT

1-Pole 10K AIC 120V AC

Ampere Rating

Catalog Number

15?15

Q1515

15?20

Q1520

20?20

Q2020

20?30

Q2030

30?15n

Q3015

30?20

Q3020

30?30

Q3030

SHIPPING: 12 per carton, (Wt. 4.8 lbs.)

Triplex Circuit Breakers

Ampere Rating

Breaker Type

QT

2-Pole 10K AIC 120/240V AC Inner Poles Common Trip

Single Pole

Common-Trip 2-Pole

15

15

15

20

15

25

15

30

15

35

15

40

15

45

15

50

20

20

20

25

20

30

20

35

20

40

20

45

20

50

30

30

SHIPPING: 6 per carton, (Wt. 4.9 lbs.)

Quadplex Circuit Breakers

Ampere Rating

Breaker Type

QT

2-Pole 10K AIC 120/240V AC Inner and Outter 2 Poles Common Trip

Common-Trip 2-Pole Outside

Common-Trip 2-Pole Inside

15

15

15

30

20

20

20

50

30

20

30

25

30

30

30

50

40

20

40

30

40

40

SHIPPING: 6 per carton, (Wt. 4.8 lbs.)

Catalog Number Q1515NCa Q1520NCa Q2020NCa -- -- -- Q3030NCa

Catalog Number Q21515CT Q21520CT Q21525CTn Q21530CT Q21535CTn Q21540CT Q21545CTn Q21550CT Q22020CT Q22025CTn Q22030CT Q22035CTn Q22040CT Q22045CTn Q22050CT Q23030CT

Catalog Number Q21515CT2 Q21530CT2 Q22020CT2 Q22050CT2 Q23020CT2 Q23025CT2 Q23030CT2 Q23050CT2 Q24020CT2 Q24030CT2 Q24040CT2

QT Duplex These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated.

QT Triplex These space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated.

QT Quadplex These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated.

For external accessories, please refer to page 1-43.

For inches / millimeters conversion, see Application Data section.

Product Category RESI

n Built to order. Allow 2?3 weeks for delivery.

a Non-CTL. For replacement use only in panels manufactured before 1968

Siemens Industry, Inc. SPEEDFAXTM 2017 Product Catalog 1-37

LOAD CENTERS & 1

CIRCUIT BREAKERS

Circuit Breakers

Special Application Breakers

HID Lighting

For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker.

Breaker Type

QP

1-Pole 120VAC

QP

2-Pole 120/240VAC

Wiring Diagram Figure 1

Figure 2

Complete Breaker UL Unenclosed

Ampere Rating Catalog Number

15

Q115HID an

20

Q120HID a

30

Q130HID

15

Q215HID

20

Q220HID n

30

Q230HIDn

Molded Case Switch

For applications that do not require overcurrent protection.

QP

1-Pole

120V AC

Figure 1

100

QP

30

2-Pole 120/240V AC

Figure 2

50 60

125

Q1100S

Q230S Q250S Q260S Q2125S

No-Noise

For applications that require a reduction in the 60-cycle hum of

a standard breaker.

QP

2-Pole

Figure 2

50 60

120/240V AC

Q250NNn Q260NN

Switching Neutrals

Used where all conductors are required to be disconnected. Neutral pole of the circuit breaker does not connect to load center bus. One side is wired to neutral and the other side to the device.

QG

2-Wire Common Trip

Figure 3

15 20

120V AC

QG

3-Wire

Figure 4

20

Common Trip

120/240V AC

QG215 QG220

QG320

Switching Neutral

Figure 1

Figure 2

Figure 3

Figure 4

Wiring Diagrams

n Built to order. Allow 2?3 weeks for delivery.

Note: All circuit breakers on this page are 10K AIC

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.