Hollow Fiber Membrane Type Air Drier Unit Dry Unit
Hollow Fiber Membrane Type Air Drier Unit
Dry Unit
No electric power supply is required. Air Filter, Mist Filter (Micromist Filter) and Regulator are integrated.
Space-saving type achieving direct connection to air source.
Air Filter
Mist Filter or Micromist Filter
Regulator Fiber Dry
Pressure Gauge Option - Bourdon tube Compact Pressure Gauge Battery Operated Digital Display Gauge Dual LCD Display Pressure Sensor Switch
0.5 0 MPa 1
Air preparation Series
Dry Unit
Model Designation (Example)
'.%3
8
"%
Unit Type
Flow Rate
Inlet-side Connection Port
Outlet-side Connection Port
Pressure Display Flow Direction Drainage Cock
Unit Type Code FD FDR FBD FMD FBDR FMDR
Air Filter
Mist Filter
Micromist Filter
Fiber Dry
Regulator
Flow Rate
Code
100
301
Flow Rate(l/min(ANR))
100
300
Inlet Port (*For Rc thread (02 and 03), size of Inlet and Outlet Ports are same.) 02Rc1/4(Refer to Table 1) 03Rc3/8(Refer to Table 1) C6(e.g.)Fitting Size (Refer to Table 2)
Outlet Port (* Selectable for Fitting Size only) No CodeSame size as Inlet port C6(e.g.)Fitting Size (Refer to Table 2)
Drainage Cock MDManual Drain Cock ADAuto Drain Cock
Flow Direction No CodeLeft to Right RRight to Left
Table 1. Thread Size (Female)
100 Series
02
03
FD
FDR
FBD
FMD
FBDR
FMDR
301 Series
02
03
Table 2. Thread Size of Push-In Fitting
C Straight Type L Elbow Type ?D
W Double Banjo Type ?D
?D
Code Size(?D) Code Size(?D) Code Size(?D)
C4
4mm
L4
4mm
W4
4mm
C6
6mm
L6
6mm
W6
6mm
C8
8mm
L8
8mm
W8
8mm
C10 10mm L10 10mm W10 10mm
C12 12mm L12 12mm W12 12mm
C16 16mm L16 16mm * Outlet Port only
* Only when Manual Drain is selected,fitting push-in fitting size ?4mm or ?6mm is selectable.
* Inch sizes of 5/32", 1/4", 3/8", 1/2" and 5/8" are available.
Ask us for the details.
Pressure Gauge No entryBourdon tube pressure gauge LNo gauge GDigital pressure gauge T2Dual LCD digital pressure sensor1 point SW analog output2m cable T2CDual LCD digital pressure sensor1point SWanalog outputM8, 4-pin male connector T3Dual LCD digital pressure sensor2 points SW output2m cable T3CDual LCD digital pressure sensor2 points SW outputM8, 4-pin male connector T4Dual LCD digital pressure sensorNPN output, 2 points SW outputanalog output T4PDual LCD digital pressure sensorPNP output, 2 points SW outputanalog output T5Dual LCD digital pressure sensor NPN output, 2 points SW outputcopy function T5PDual LCD digital pressure sensor PNP output, 2 points SW outputcopy function
Specification
Please refer to the specification of the following product website
Air Filter ......... Air, Mist, Micromist Filter Mist Filter ......... Air, Mist, Micromist Filter Micro Mist Filter ......... Air, Mist, Micromist Filter Regulator ......... Pressure Regulator Drier ......... Fiber Dry Digital Pressure Gauge ......... Filter Regulator Dual LCD Digital Pressure Sensor ...... Filter Regulator
Dehumidifying Performance Chart
100 Series
301 Series
Achieved Dew Point (At atmospheric pressure) ()
Achieved Dew Point (At atmospheric pressure) ()
0
Inlet Pressure0.7MPa Air Temp.20
-10 HumiditySaturation
-20
-30
-40
Circuit1
Circuit2
Circuit3
10 20 30 40 50 60 70 80 90 100 110 Operating Flow Rate (l/min(ANR))
0
Inlet Pressure0.7MPa Air Temp.20
-10 HumiditySaturation
-20
-30
-40
Circuit1
Circuit2 Circuit3
50
100
150
200
250
300
350
Operating Flow Rate(l/min(ANR))
Purging Flow Chart
100 Series
301 Series
Purging Flow (l/min(ANR))
Purging Flow (l/min(ANR))
40
80
30
Circuit3
Circuit3
60
Circuit2
20
Circuit2
40
Circuit1
10
20
Circuit1
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Inlet Pressure (MPa)
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Inlet Pressure (MPa)
0.5 0 MPa 1
Air preparation Series
Dry Unit
Calculation Method of Dehumidification Amount
Conditions
Fig. 2 (Table of Saturated Vapor Amount)
Dehumification amount is under the following condition. Compressed air of temp.: 20oC, humidity: 100%, pressure: 0.7MPa is dehumidified up to dew point -25oC by an air dryer.
Temp. (?C) -50 -49
Vapor Amount (g/m3) 0.0617 0.0689
Temp. (?C)
0 1
Vapor Amount (g/m3) 4.85 5.19
-48
Example: Calculation Method of Atmospheric Dew Point
-47
(Temp.: 20oC, Humidity: 100%, Pressure: 0.7MPa)
-46
0.0767 0.0853 0.095
2
5.56
3
5.95
4
6.36
Fig. 1
-45
Atmospheric Dew Point......... 8
-44
Check the saturated vapor at -8oC and -25oC in the
-43
-42
figure 1.
-41
Fig. 2
-40
Amount of saturated vapor at -8.........2.74g/m3
-39
0.106 0.117 0.13 0.144 0.159 0.176 0.194
5
6.79
6
7.26
7
7.75
8
8.27
9
8.82
10
9.4
11
10
Amount of saturated vapor at -25.........0.705g/m3 2.74 0.705 2.035 Dehumidification Amount.........2.035g/m3
-38
0.214
-37
0.236
-36
0.26
-35
0.286
12
10.7
13
11.3
14
12.1
15
12.8
-34
0.314
16
13.6
-33
0.345
17
14.5
-32
0.378
18
15.4
-31
0.414
19
16.3
-30
0.453
20
17.3
-29
0.496
21
18.3
Fig. 1 (Atmospheric Dew Point)
60
Pressure (MPa)
3
0.4 2.8 2.1 1.8 1.4 1.1 0.70.60.5 0.3
0.2
-28
0.542
-27
0.592
-26
0.646
22
19.4
23
20.6
24
21.8
Pressure Dew Point Temp.()
55
0.1
-25
0.705
25
23
50
-24
0.768
26
24.4
45
-23
0.863
27
25.8
40
-22
0.909
28
27.2
35
-21
0.989
29
28.7
30
-20
1.07
30
30.3
25
-19
1.17
31
32.3
20
-18
1.26
32
33.8
15
10
-17
1.37
33
35.6
5
-16
1.48
34
37.5
0
-15
1.61
35
39.6
-5
Atmospheric pressure
-14
1.74
36
41.7
-10
-13
1.88
37
43.9
-15
-12
2.03
38
46.2
-20
-11
2.19
39
43.6
-25 -30 -35 -40 -45 -50 -55 -60 -65
-65 -60 -55 -50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 Atmospheric Dew Point()
-10
2.36
-9
2.54
-8
2.74
-7
2.95
-6
3.17
-5
3.41
-4
3.66
-3
3.93
-2
4.22
-1
4.52
40
51.5
41
53.7
42
56.4
43
59.3
44
62.2
45
65.3
46
68.5
47
71.9
48
75.4
49
79
50
82.8
Conversion Table of Dew Point, Vapor Amount and Relative Humidity
Dew Point ( ) 30 25 20 15 10 5 0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50
Vapor Amount (g/m3) 30.3 23.0 17.3 12.8 9.40 6.79 4.85 3.41 2.36 1.01 1.07 0.705 0.453 0.286 0.176 0.106 0.0617
Air Temp. 20 100 74 54 39 28 18 12 8.2 5.1 3.2 2.0 1.2 0.89 0.40 0.22
Relative Humidity (%) Air Temp. 25 100 75 55 41 30 21 14 9.3 6.0 3.8 2.4 1.5 0.88 0.52 0.30 0.17
Air Temp. 30 100 76 57 42 31 22 16 11 7.1 4.6 2.9 1.8 1.1 0.67 0.39 0.22 0.13
Detailed Safety Instructions
Before using PISCO products, be sure to read "Safety Instructions" and "Safety Instruction Manual" and Common Safety Instructions for Fiber Dry and Dry Unit".
Caution 1. Make sure to adjust the pressure of the regulator in the increasing direction and lock it
by pressing the lock button after adjustment. 2. Air is exhauseted from the drain port until the supply pressure rises to 0.05MPa for
Manual Drain Type and to 0.15Mpa for Auto Drain Type. During this time, the air will not stop coming out even if the drain knob is turned. (Contact PISCO for instructions if the time is too long before the supply pressure rises to 0.15MPa) 3. Adjust the drain knob with fingers. 4. Inner size 6mm of Nylon Tube is required for the fitting of Manual Drain Type. Do not bend the tube near the fitting. 5. The fitting of Manual Drain is rotatable. No need to detach a tube even when drain is discharged by hand. 6. Do not exceed the setting pressure (Max. 0.85MPa) of Regulator. Otherwise, it may cause malfunctions.
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- ecd 745
- tourist arrivals to israel exc day visitors cruise
- series 988 989 the series 988 989 offers more features
- warrnambool
- software release document
- product catalog net framework
- set up the internet of things edge platform mqtt
- hollow fiber membrane type air drier unit dry unit
- top 50 fixed income funds ranked by quarterly returns
- kts 560 590 kts 5a series module for control unit
Related searches
- carbon fiber rifle stock
- type a unit ibc
- type b unit requirements
- ada type a unit requirements
- 75 kva dry type transformer
- custom carbon fiber rifle stocks
- air force unit identification code
- central heat and air unit prices
- 5g fiber stock
- green light fiber optic internet
- myelinated nerve fiber icd 10
- myelinated nerve fiber layer code